Osseodensification for enhancement of spinal surgical hardware fixation
Source abstract
Abstract
Integration between implant and bone is an essential concept for osseous healing requiring hardware placement. A novel approach to hardware implantation, termed osseodensification, is described here as an effective alternative. 12 sheep averaging 65kg had fixation devices installed in their C2, C3, and C4 vertebral bodies; each device measured 4mm diameter×10mm length. The left-sided vertebral body devices were implanted using regular surgical drilling (R) while the right-sided devices were implanted using osseodensification drilling (OD). The C2 and C4 vertebra provided the t=0 in vivo time point, while the C3 vertebra provided the t=3 and t=6 week time points, in vivo. Structural competence of hardware was measured using biomechanical testing of pullout strength, while the quality and degree of new bone formation and remodeling was assessed via histomorphometry. Pullout strength demonstrated osseodensification drilling to provide superior anchoring when compared to the control group collapsed over time with statistical significance (p<0.01). On Wilcoxon rank signed test, C2 and C4 specimens demonstrated significance when comparing device pullout (p=0.031) for both, and C3 pullout tests at 3 and 6 weeks collapsed over time had significance as well (p=0.027). Percent bone-to-implant contact (%BIC) analysis as a function of drilling technique demonstrated an OD group with significantly higher values relative to the R group (p<0.01). Similarly, percent bone-area-fraction-occupancy (BAFO) analysis presented with significantly higher values for the OD group compared to the R group (p=0.024). As a function of time, between 0 and 3 weeks, a decrease in BAFO was observed, a trend that reversed between 3 and 6 weeks, resulting in a BAFO value roughly equivalent to the t=0 percentage, which was attributed to an initial loss of bone fraction due to remodeling, followed by regaining of bone fraction via production of woven bone. Histomorphological data demonstrated autologous bone chips in the OD group with greater frequency relative to the control, which acted as nucleating surfaces promoting new bone formation around the implants, providing superior stability and greater bone density. This alternative approach to a critical component of hardware implantation encourages assessment of current surgical approaches to hardware implantation.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (45)
Show source-provided references
1. Osseointegration of bone implants: a review of an alternative mode of fixation10.3109/17453678709146401 ↗
2. Osseointegrated titanium implants: requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man10.3109/17453678108991776 ↗
3. Transcutaneous, distal femoral, intramedullary attachment for above-the-knee prostheses: an endo-exo device10.2106/JBJS.J.00806 ↗
4. Biomechanical study of lumbar pedicle screws: does convergence affect axial pullout strength?
5. Hydroxyapatite-based biomaterials versus autologous bone graft in spinal fusion: an in vivo animal study10.1097/BRS.0000000000000311 ↗
6. Osseointegration of metallic devices: current trends based on implant hardware design10.1016/j.abb.2014.06.033 ↗
7. Biomechanical and histologic evaluation of non‐washed resorbable blasting media and alumina‐blasted/acid‐etched surfaces10.1111/j.1600-0501.2010.02147.x ↗
8. Stevenel's blue, an excellent stain for optical microscopical study of plastic embedded tissues
9. Lumbar transpedicular implant failure: a clinical and surgical challenge and its radiological assessment10.4184/asj.2014.8.3.281 ↗
10. In vivo osseointegration of nano-designed composite coatings on titanium implants10.1021/nn200768c ↗
11. A computerized image analysis method for measuring elastic tissue10.1016/0022-202X(89)90059-6 ↗
12. Autologous osteoblasts enhance osseointegration of porous titanium implants10.1016/S0736-0266(02)00143-2 ↗
13. The effect of osteotomy dimension on osseointegration to resorbable media-treated implants: a study in the sheep10.1177/0885328214553958 ↗
14. Osteoconductive potential of mesoporous titania implant surfaces loaded with magnesium: an experimental study in the rabbit10.1111/cid.12211 ↗
15. Effect of drilling technique on the early integration of plateau root form endosteal implants: an experimental study in dogs10.1016/j.joms.2011.01.029 ↗
16. The effect of simplifying dental implant drilling sequence on osseointegration: an experimental study in dogs10.1155/2013/230310 ↗
17. Osseodensification: a novel approach in implant o preparation to increase primary stability, bone mineral density and bone to implant contact
18. A method for histological preparation of undecalcified bone sections containing acrylic bone cement10.3109/10520299109110555 ↗
19. Biomechanical evaluation of the pedicle screw insertion depth effect on screw stability under cyclic loading and subsequent pullout
20. Cell based therapies as compared to autologous bone grafts for spinal arthrodesis10.1097/BRS.0b013e3182a3d7dc ↗
21. Biomechanical and histologic basis of osseodensification drilling for endosteal implant placement in low density bone. an experimental study in sheep10.1016/j.jmbbm.2016.06.007 ↗
22. A study of the bone healing kinetics of plateau versus screw root design titanium dental implants10.1111/j.1600-0501.2008.01640.x ↗
23. Titanium, a metal for surgery10.2106/00004623-195133020-00021 ↗
24. Clinical aspects of osseointegration in joint replacement. A histological study of titanium implants10.1302/0301-620X.70B4.3403596 ↗
25. Analysis of porous ingrowth in intervertebral disc prostheses: a nonhuman primate model10.1097/01.BRS.0000048504.08086.42 ↗
26. Thermal damage during humeral reaming in total shoulder resurfacing10.4103/0973-6042.118910 ↗
27. Radiographic evaluation of osseointegration and loosening of titanium implants in the MCP and PIP joints10.1016/j.jhsa.2003.10.001 ↗
28. Evaluation of osseointegration around tibial implants in rats by ibandronate-treated nanotubular ti-32nb-5zr alloy10.4062/biomolther.2014.111 ↗
29. Drilling of bone: a comprehensive review10.1016/j.jcot.2013.01.002 ↗
30. Spine interbody implants: material selection and modification, functionalization and bioactivation of surfaces to improve osseointegration
31. Graft options in posterolateral and posterior interbody lumbar fusion10.1097/BRS.0b013e3181d25803 ↗
32. Enhanced osseointegration of titanium implants with nanostructured surfaces: an experimental study in rabbits10.1016/j.actbio.2014.10.017 ↗
33. Hydroxyapatite coating improves fixation of pedicle screws10.1302/0301-620X.84B3.0840387 ↗
34. Effect of low speed drilling on osseointegration using simplified drilling procedures10.1016/j.bjoms.2015.03.010 ↗
35. Use of hydroxyapatite in spine surgery10.1007/s005860100286 ↗
36. Osseointegrated titanium implants for limb prostheses attachments: infectious complications10.1007/s11999-010-1370-0 ↗
37. Two alternative surgical techniques for enhancing primary implant stability in the posterior maxilla: a clinical study including bone density, insertion torque, and resonance frequency analysis data10.1111/j.1708-8208.2008.00084.x ↗
38. Walking ability and quality of life in subjects with transfemoral amputation: a comparison of osseointegration with socket prostheses10.1016/j.apmr.2013.05.020 ↗
39. Surface characterization, biomechanical, and histologic evaluation of alumina and bioactive resorbable blasting textured surfaces in titanium implant healing chambers: an experimental study in dogs10.11607/jomi.2952 ↗
40. The effect of drilling speed on early bone healing to oral implants10.1016/j.oooo.2013.07.001 ↗
41. Revision of failed pedicle screws using hydroxyapatite cement: a biomechanical analysis10.1097/00007632-199808010-00008 ↗
42. Biomechanical comparisons of pull out strengths after pedicle screw augmentation with hydroxyapatite, calcium phosphate, or polymethylmethacrylate in the cadaveric spine10.1016/j.wneu.2015.01.056 ↗
43. Hydroxyapatite dip coated and uncoated titanium poly-axial pedicle screws: an in vivo bovine model10.1097/01.brs.0000210221.00778.c7 ↗
44. Synergistic effects of surface chemistry and topologic structure from modified microarc oxidation coatings on ti implants for improving osseointegration10.1021/acsami.5b02226 ↗
45. Structure, MC3T3-E1 cell response, and osseointegration of macroporous titanium implants covered by a bioactive microarc oxidation coating with microporous structure10.1021/am405680d ↗