journal article·2018-10

Impact of annular and supra-annular CoreValve deployment locations on aortic and coronary artery hemodynamics

Harkamaljot S. Kandail, Setu D. Trivedi, Armaan C. Shaikh, Tanvir K. Bajwa, Daniel P. O’Hair, Arshad Jahangir, John F. LaDisa

Publisher page

Abstract

CoreValve is widely used in transcatheter aortic valve replacement, but the impact of its deployment location on hemodynamics is unexplored despite a potential role in subsequent aortic and coronary artery pathologies. The objectives of this investigation were to perform fluid-structure interaction (FSI) simulations for a 29 mm CoreValve deployed in annular vs supra-annular locations, and characterize resulting hemodynamics including velocity and wall shear stress (WSS). Patient-specific geometry was reconstructed from computed tomography scans and CoreValve was deployed using a finite element approach. FSI simulations were then performed using a boundary conforming method and realistic boundary conditions. Results showed that CoreValve deployment location impacts hemodynamics in the ascending aorta and flow patterns in the coronary arteries. During peak-systole, annularly deployed CoreValve produced a jet-like flow structure impinging on the outer-curvature of the ascending aorta. Supra-annularly deployed CoreValve having a lateral tilt of 10° led to a more centered jet impinging further downstream. At mid-systole, valve leaflets of the annularly deployed CoreValve closed asymmetrically leading to disorganized flow patterns in the ascending aorta vs those from the supra-annular position. Supra-annularly deployed CoreValve also led to high-velocity para-valvular flow supplying the coronary arteries. CoreValve in the supra-annular position significantly (P < 0.05) elevated WSS within the first few diameters of both coronary arteries as compared to the annular position for many time points quantified. These results afforded by the advanced simulation methods may have important clinical implications given the role of aortic hemodynamics in dilation and the pro-atherogenic nature of WSS alterations in the coronary arteries.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Cardiac Valve Diseases and Treatments · Coronary Interventions and Diagnostics · Cardiovascular Function and Risk Factors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (50)

Show source-provided references
1. Incidence, feasibility and outcome of percutaneous coronary intervention after transcatheter aortic valve implantation with a self-expanding prosthesis. Results from a single center experience10.1016/j.carrev.2016.05.010 ↗
2. Incidence and predictors of coronary obstruction following transcatheter aortic valve implantation in the real world
3. Comparison of echocardiographic abnormalities in African-American, Hispanic, and white men and women aged >60 years10.1016/S0002-9149(01)01480-1 ↗
4. Prevalence, referral patterns, testing, and surgery in aortic valve disease: leaving women and elderly patients behind?
5. Fluid-structure interaction simulation of prosthetic aortic valves: comparison between immersed boundary and arbitrary Lagrangian-Eulerian techniques for the mesh representation10.1371/journal.pone.0154517 ↗
6. Heart disease and stroke statistics-2017 update: a report from the American Heart Association10.1161/CIR.0000000000000485 ↗
7. Left main coronary artery disease: assessment, diagnosis, and therapy10.1016/0002-8703(95)90018-7 ↗
8. Blood flow and coherent vortices in the normal and aneurysmatic aortas: a fluid dynamical approach to intra-luminal thrombus formation10.1098/rsif.2011.0041 ↗
9. Challenges of coronary angiography and intervention in patients previously treated by TAVI10.1007/s00392-015-0824-5 ↗
10. The stress/strain and fatigue behaviour of glutaraldehyde preserved heart-valve tissue10.1016/0021-9290(77)90086-0 ↗
11. CoreValve® transcatheter self-expandable aortic bioprosthesis10.1586/erd.12.64 ↗
12. Modeling left ventricular blood flow using smoothed particle hydrodynamics10.1007/s13239-017-0324-z ↗
13. Development of an in vitro model to characterize the effects of transcatheter aortic valve on coronary artery flow10.1111/aor.12589 ↗
14. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description10.1161/01.CIR.0000047200.36165.B8 ↗
15. Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis10.1016/j.jacc.2003.11.026 ↗
16. Thrombus formation following transcatheter aortic valve replacement10.1016/j.jcin.2015.03.005 ↗
17. Transcatheter aortic valve-in-valve implantation for patients with degenerative surgical bioprosthetic valves10.1016/j.cpcardiol.2013.10.001 ↗
18. Aortic valve replacement in octogenarians: identification of high-risk patients10.1016/j.ejcts.2009.12.025 ↗
19. FlowVision User’s Guide 2015, version 3.09.05. Available at: 〈https://fv-tech.com/webhelp/fven_31002/〉.
20. Deaths: leading causes for 2008
21. Deaths: preliminary data for 2011
22. Fluid-structure interaction analysis of bioprosthetic heart valves: significance of arterial wall deformation10.1007/s00466-014-1059-4 ↗
23. Natural history of aortic valve stenosis of varying severity in the elderly10.1016/S0002-9149(96)00235-4 ↗
24. Patient-specific modeling of blood flow and pressure in human coronary arteries10.1007/s10439-010-0083-6 ↗
25. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery10.1056/NEJMoa1008232 ↗
26. A nonlinear anisotropic model for porcine aortic heart valves10.1016/S0021-9290(01)00092-6 ↗
27. Evaluation of an aortic valve prosthesis: fluid-structure interaction or structural simulation?10.1016/j.jbiomech.2017.04.004 ↗
28. Fluid-structure interaction study of transcatheter aortic valve dynamics using smoothed particle hydrodynamics10.1007/s13239-016-0285-7 ↗
29. Fully-coupled fluid-structure interaction simulation of the aortic and mitral valves in a realistic 3D left ventricle model10.1371/journal.pone.0184729 ↗
30. Numerical methods for fluid-structure interaction models of aortic valves10.1007/s11831-014-9133-9 ↗
31. Predicting false lumen thrombosis in patient-specific models of aortic dissection10.1098/rsif.2016.0759 ↗
32. Valve type, size, and deployment location affect hemodynamics in an in vitro valve-in-valve model10.1016/j.jcin.2016.05.030 ↗
33. Deaths: final data for 2008
34. Sequential structural and fluid dynamic numerical simulations of a stented bifurcated coronary artery10.1115/1.4005476 ↗
35. Patient-specific simulations of stenting procedures in coronary bifurcations: two clinical cases10.1016/j.medengphy.2013.01.007 ↗
36. Delayed prosthesis malposition after transcatheter aortic valve implantation causing coronaries obstruction10.1093/ejcts/ezx266 ↗
37. 2017 AHA/ACC focused update of the 2014 AHA/ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task force on clinical practice guidelines10.1161/CIR.0000000000000503 ↗
38. The Society of Thoracic Surgeons 2008 cardiac surgery risk models: part 2 – isolated valve surgery10.1016/j.athoracsur.2009.05.056 ↗
39. Health status after transcatheter aortic valve replacement in patients at extreme surgical risk: results from the CoreValve U.S. trial10.1016/j.jcin.2014.08.016 ↗
40. A computational framework for investigating the positional stability of aortic endografts10.1007/s10237-012-0450-3 ↗
41. Geometry and degree of apposition of the CoreValve revalving system with multislice computed tomography after implantation in patients with aortic stenosis10.1016/j.jacc.2009.04.075 ↗
42. The Society of Thoracic Surgeons 2008 cardiac surgery risk models: part 3-valve plus coronary artery bypass grafting surgery10.1016/j.athoracsur.2009.05.055 ↗
43. Outcomes of surgical aortic valve replacement in high-risk patients: a multiinstitutional study10.1016/j.athoracsur.2010.09.040 ↗
44. Predicting impending rupture of the ascending aorta with bicuspid aortic valve: spatiotemporal flow and wall shear stress10.1016/j.jcmg.2013.02.012 ↗
45. Supra-annular valve-in-valve implantation reduces blood stasis on the transcatheter aortic valve leaflets10.1016/j.jbiomech.2017.04.020 ↗
46. Effect of reduced cardiac output on blood stasis on transcatheter aortic valve leaflets: implications for valve thrombosis10.4244/EIJ-D-17-00094 ↗
47. Blood stasis on transcatheter valve leaflets and implications for valve-in-valve leaflet thrombosis10.1016/j.athoracsur.2017.02.052 ↗
48. Valve thrombosis following transcatheter aortic valve replacement: significance of blood stasis on the leaflets
49. Percutaneous aortic valve implantation retrograde from the femoral artery10.1161/CIRCULATIONAHA.105.582882 ↗
50. Fluid-structure interaction model of a percutaneous aortic valve: comparison with an in vitro test and feasibility study in a patient-specific case10.1007/s10439-015-1429-x ↗