Viscoelastic properties of a synthetic meniscus implant
Source abstract
Abstract
There are significant potential advantages for restoration of meniscal function using a bio-stable synthetic implant that combines long-term durability with a dependable biomechanical performance resembling that of the natural meniscus. A novel meniscus implant made of a compliant polycarbonate-urethane matrix reinforced with high modulus ultrahigh molecular weight polyethylene fibers was designed as a composite structure that mimics the structural elements of the natural medial meniscus. The overall success of such an implant is linked on its capability to replicate the stress distribution in the knee over the long-term. As this function of the device is directly dependent on its mechanical properties, changes to the material due to exposure to the joint environment and repeated loading could have non-trivial influences on the viscoelastic properties of the implant. Thus, the goal of this study was to measure and characterize the strain-rate response, as well as the viscoelastic properties of the implant as measured by creep, stress relaxation, and hysteresis after simulated use, by subjecting the implant to realistic joint loads up to 2 million cycles in a joint-like setting. The meniscus implant behaved as a non-linear viscoelastic material. The implant underwent minimal plastic deformation after 2 million fatigue loading cycles. Under low compressive loads, the implant was fairly flexible, and able to deform relatively easily (E=120-200 kPa). However as the compressive load applied on the implant was increased, the implant became stiffer (E=3.8-5.2 MPa), to resist deformation. The meniscus implant appears well-matched to the viscoelastic properties of the natural meniscus, and importantly, these properties were found to remain stable and minimally affected by potentially degradative and loading conditions associated with long-term use.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Knee injuries and reconstruction techniques · Adhesion, Friction, and Surface Interactions · Tribology and Wear Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (53)
Show source-provided references
1. In-vitro measurement of static pressure distribution in synovial joints—Part I: tibial surface of the knee10.1115/1.3138409 ↗
2. Anatomy and biomechanics of the meniscus10.1016/S1048-6666(95)80041-7 ↗
3. Late degenerative changes after meniscectomy. factors affecting the knee after operation
4. The shocking truth about meniscus10.1016/j.jbiomech.2011.08.026 ↗
5. Engineering the knee meniscus10.1007/978-3-031-02576-1_3 ↗
6. The role of interstitial fluid pressurization in articular cartilage lubrication10.1016/j.jbiomech.2009.04.040 ↗
7. Sports injury, occupational physical activity, joint laxity, and meniscal damage
8. Dynamic contact mechanics of the medial meniscus as a function of radial tear, repair, and partial meniscectomy10.2106/JBJS.I.00539 ↗
9. The strength of the menisci of the knee as it relates to their fine structure
10. Dynamic compressive behavior of human meniscus correlates with its extra-cellular matrix composition
11. Compressive moduli of the human medial meniscus in the axial and radial directions at equilibrium and at a physiological strain rate10.1002/jor.20573 ↗
12. In-vivo degradation of poly(carbonate-urethane) based spine implants10.1016/j.polymdegradstab.2013.03.005 ↗
13. DSM/Dyneema Purity® website: 〈http://www.dsm.com/en_US/medical/public/home/downloads/publications/Dyneema_Purity_UG_VG_fiber.pdf?fileaction=openFile〉.
14. Fatigue behaviour of multiblock thermoplastic elastomers. 2. Dynamic creep of poly(aliphatic/aromatic-ester) copolymers10.1016/S0032-3861(03)00418-X ↗
15. Design of a free-floating polycarbonate-urethane meniscal implant using finite element modeling and experimental validation10.1115/1.4001892 ↗
16. Wear rate evaluation of a novel polycarbonate-urethane cushion form bearing for artificial hip joints10.1016/j.actbio.2010.07.011 ↗
17. Long-term evaluation of a compliant cushion form acetabular bearing for hip joint replacement: a 20 million cycles wear simulation10.1002/jor.21471 ↗
18. Incidental meniscal findings on knee MRI in middle-aged and elderly persons10.1056/NEJMoa0800777 ↗
19. Material properties and structure-function relationships in the menisci10.1097/00003086-199003000-00004 ↗
20. Fung Y.C. Biomechanics. Mechanical properties of living tissues. 2nd Ed. Springer, New York, USA, 1993.10.1115/1.2901550 ↗
21. Characterisation of Bionate polycarbonate polyurethanes for orthopaedic applications
22. Changes in articular cartilage after meniscectomy and meniscus replacement using a biodegradable porous polymer implant10.1007/s00167-010-1244-8 ↗
23. Chemical changes of human knee joint menisci in various stages of degeneration10.1136/ard.43.4.635 ↗
24. Interspecies variation of compressive biomechanical properties of the meniscus10.1002/jbm.820290706 ↗
25. Cartilage stress-relaxation proceeds slower at higher compressive strains10.1016/j.abb.2008.11.029 ↗
26. Changes of human menisci in osteoarthritic knee joints10.1016/j.joca.2010.05.017 ↗
27. Kelm L.N. Hysteresis Response of Articular Cartilage to Cyclic Loading. Rice University, Houston, TX, MSc thesis, 2002.
28. Creep behavior of the intact and meniscectomy knee joints10.1016/j.jmbbm.2011.05.004 ↗
29. Analysis and evaluation of a biomedical polycarbonate urethane tested in an in vitro study and an ovine arthroplasty model. Part I: materials selection and evaluation10.1016/j.biomaterials.2004.02.065 ↗
30. A two year in vivo study of polyvinyl alcohol-hydrogel (PVA-H) artificial meniscus10.1016/j.biomaterials.2004.08.028 ↗
31. Load-Bearing Mode of the Knee Joint: Physical Behavior of the Knee Joint With or Without Menisci10.1097/00003086-198006000-00039 ↗
32. Strain-rate dependent stiffness of articular cartilage in unconfined compression10.1115/1.1560142 ↗
33. A novel quantitative approach for evaluating contact mechanics of meniscal replacements10.1115/1.4000407 ↗
34. The effect of lateral meniscectomy on motion of the knee10.2106/00004623-198971030-00014 ↗
35. The long-term consequence of anterior cruciate ligament and meniscus injuries: osteoarthritis10.1177/0363546507307396 ↗
36. The apparent viscoelastic behavior of articular cartilage - the contributions from the intrinsic matrix viscoelasticity and interstitial fluid flows10.1115/1.3138591 ↗
37. The consequences of meniscectomy
38. Biomechanics of the menisci of the knee10.1016/j.cuor.2008.04.005 ↗
39. McCrum · 2003
40. Traumatic loading of articular cartilage: mechanical and biological responses and post-injury treatment
41. An analytical–numerical framework for the study of ageing in fibre reinforced polymer composites10.1016/j.compstruct.2003.12.006 ↗
42. Mechanical response of bovine articular cartilage under dynamic unconfined compression loading at physiological stress levels10.1016/j.joca.2003.08.005 ↗
43. Occupational kneeling and meniscal tears: a magnetic resonance imaging study in floor layers10.3899/jrheum.081150 ↗
44. Effect of cyclic preconditioning on the tensile properties of human quadriceps tendons and patellar ligaments
45. Role of cartilage collagen fibrils networks in knee joint biomechanics under compression10.1016/j.jbiomech.2008.09.033 ↗
46. Contributions of muscles, ligaments, and the ground-reaction force to tibiofemoral joint loading during normal gait10.1002/jor.20255 ↗
47. Biphasic poroviscoelastic behavior of hydrated biological soft tissue
48. Meniscal tear characteristics in young athletes with a stable knee: arthroscopic evaluation10.1177/0363546506287939 ↗
49. Tensile stress-strain characteristics of the human meniscal material10.1016/0021-9290(94)00081-E ↗
50. The viscoelastic properties of the human semilunar cartilage10.1016/0021-9290(79)90010-1 ↗
51. Tissue ingrowth and degradation of two biodegradable porous polymers with different porosities and pore sizes.10.1016/S0142-9612(01)00280-0 ↗
52. Winby C.R., Lloyd D.G., Besier T.F., Kirk T.B. 2009. Muscle and external load contribution to knee joint contact loads during normal gait. Journal of Biomechanics.16;42(14):2294–2300.10.1016/j.jbiomech.2009.06.019 ↗
53. Ward · 2004