journal article·2016-06Open access

Influence of the overall stiffness of a load-bearing porous titanium implant on bone ingrowth in critical-size mandibular bone defects in sheep

T. Schouman, M. Schmitt, C. Adam, G. Dubois, P. Rouch

Abstract

The aim of this work was to assess the influence of reduction of the apparent mechanical properties of fully load-bearing porous titanium implants used in mandibular bone defects. Segmental 18mm long bone defects were created bilaterally in the lower jaws of adult ewes. One group of 6 ewes (group A) was treated with load-bearing 'rigid' (high stiffness) porous implants on the right side, and with control on the left side. A second group of 6 ewes (group B) was treated with 'flexible' porous and control implants exhibiting apparent mechanical properties ten times lower than the rigid implants. The mechanical behavior of the reconstructed hemi-mandibles was assessed by cantilever testing and bone ingrowth into the segmental defects was assessed by BV/TV measurement within the implant using micro-CT 12 weeks after implantation. A significantly higher rigidity was identified for porous implants compared with control implants at the anterior interface in group B. BV/TV of porous implants was significantly higher than that of control implants in group A. BV/TV differences were significant between porous and control implants in group B and were homogeneous along the main axis. Significantly higher BV/TV was identified in most sub-volumes of group B porous implants compared with group A. This work highlights the critical importance of the tuning of scaffolds to promote bone ingrowth with reference to the local strains occurring within the porous scaffold, which in this application was achieved using fully load-bearing low-stiffness porous titanium implants.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes · Facial Trauma and Fracture Management

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. Mechanical evaluation of mandibular defects reconstructed using osteogenic protein-1 (rhOP-1) in a sheep model: a critical analysis10.1016/j.ijom.2004.09.008 ↗
2. Development and mechanical characterization of porous titanium bone substitutes10.1016/j.jmbbm.2012.01.008 ↗
3. Computer planning and intraoperative navigation for palatomaxillary and mandibular reconstruction with fibular free flaps10.1016/j.joms.2009.12.040 ↗
4. Long-term donor-site morbidity after microsurgical fibular graft: is there a difference between the medial approach and the lateral approach?10.1016/j.joms.2011.09.038 ↗
5. Effect of formaldehyde fixation on some mechanical properties of bovine bone10.1016/0142-9612(95)98135-2 ↗
6. Bone regeneration by the osteoconductivity of porous titanium implants manufactured by selective laser melting: a histological and micro computed tomography study in the rabbit10.1089/ten.tea.2012.0753 ↗
7. Mechanical characterization of bone graft substitute ceramic cements10.1016/j.injury.2011.02.004 ↗
8. Bone formation following implantation of titanium sponge rods into humeral osteotomies in dogs: a histological and histometrical study10.1111/j.1708-8208.2008.00132.x ↗
9. Vascularized bone flaps versus nonvascularized bone grafts for mandibular reconstruction: an outcome analysis of primary bony union and endosseous implant success10.1002/(SICI)1097-0347(199901)21:1<66::AID-HED9>3.0.CO;2-Z ↗
10. Osteoinduction of porous bioactive titanium metal10.1016/S0142-9612(03)00551-9 ↗
11. Mandibular reconstruction in adults: a review10.1016/j.ijom.2008.03.002 ↗
12. Porous titanium materials with entangled wire structure for load-bearing biomedical applications10.1016/j.jmbbm.2011.09.016 ↗
13. Flexural and compressive mechanical behaviors of the porous titanium materials with entangled wire structure at different sintering conditions for load-bearing biomedical applications10.1016/j.jmbbm.2013.08.016 ↗
14. Use of computer-aided design and computer-aided manufacturing to produce orthognathically ideal surgical outcomes: a paradigm shift in head and neck reconstruction10.1016/j.joms.2009.02.007 ↗
15. Engineering craniofacial scaffolds10.1111/j.1601-6343.2005.00329.x ↗
16. Porosity of 3D biomaterial scaffolds and osteogenesis10.1016/j.biomaterials.2005.02.002 ↗
17. Acute compartment syndrome following fibula flap harvest for mandibular reconstruction10.1016/j.jcms.2010.03.012 ↗
18. Rapid prototyped porous titanium coated with calcium phosphate as a scaffold for bone tissue engineering10.1016/j.biomaterials.2008.02.021 ↗
19. Characterization of grade 2 commercially pure trabecular titanium structures10.1016/j.msec.2013.02.034 ↗
20. Mandibular reconstruction in 2004: an analysis of different techniques10.1097/01.moo.0000131444.50445.9d ↗
21. A prospective cohort study of fibula free flap donor-site morbidity in 157 consecutive patients10.1097/PRS.0b013e318221dc2a ↗
22. Three-dimensional finite element models based on in vivo microfocus computed tomography: elimination of metal artefacts in a small laboratory animal model by registration with artefact-free reference images10.1016/j.advengsoft.2009.06.002 ↗
23. Autogenous bone graft: donor sites and techniques10.2106/JBJS.J.01513 ↗
24. Titanium-based biomaterials for preventing stress shielding between implant devices and bone
25. Mechanical properties of porous titanium compacts prepared by powder sintering10.1016/j.scriptamat.2003.08.018 ↗
26. Custom-made titanium devices as membranes for bone augmentation in implant treatment: Modeling accuracy of titanium products constructed with selective laser melting10.1016/j.jcms.2015.05.006 ↗
27. Pore throat size and connectivity determine bone and tissue ingrowth into porous implants: three-dimensional micro-CT based structural analyses of porous bioactive titanium implants10.1016/j.biomaterials.2006.08.013 ↗
28. Long-term biocompatibility and osseointegration of electron beam melted, free-form-fabricated solid and porous titanium alloy: experimental studies in sheep10.1177/0885328211431857 ↗
29. In vivo performance of selective electron beam-melted Ti-6Al-4V structures10.1002/jbm.a.32337 ↗
30. Shaping the fibula without fumbling: the SynpliciTi customised guide-plate10.1016/j.bjoms.2015.02.008 ↗
31. Three-dimensional growth of differentiating MC3T3-E1 pre-osteoblasts on porous titanium scaffolds10.1016/j.biomaterials.2005.05.046 ↗
32. Mechanical properties and osteoconductivity of porous bioactive titanium10.1016/j.biomaterials.2005.03.019 ↗
33. Micro-CT-based screening of biomechanical and structural properties of bone tissue engineering scaffolds10.1007/s11517-006-0071-z ↗
34. Selective laser melting-produced porous titanium scaffolds regenerate bone in critical size cortical bone defects10.1002/jor.22293 ↗
35. Bone formation in calcium-phosphate-coated titanium mesh10.1016/S0142-9612(00)00094-6 ↗
36. Ectopic bone formation in titanium mesh loaded with bone morphogenetic protein and coated with calcium phosphate10.1097/00006534-200108000-00024 ↗
37. Rapid prototyping: porous titanium alloy scaffolds produced by selective laser melting for bone tissue engineering10.1089/ten.tec.2008.0288 ↗
38. Biomechanical stability of novel mechanically adapted open-porous titanium scaffolds in metatarsal bone defects of sheep10.1016/j.biomaterials.2014.12.010 ↗
39. Processing and biocompatibility evaluation of laser processed porous titanium10.1016/j.actbio.2007.05.009 ↗