Study on titanium-magnesium composites with bicontinuous structure fabricated by powder metallurgy and ultrasonic infiltration
Source abstract
Abstract
Titanium-magnesium (Ti-Mg) composites with bicontinuous structure have been successfully fabricated by powder metallurgy and ultrasonic infiltration for biomaterial potential. In the composites, Ti phase is distributed continuously by sintering necks, while Mg phase is also continuous, distributing at the interconnected pores surrounding the Ti phase. The results showed that the fabricated Ti-Mg composites exhibited low modulus and high strength, which are very suitable for load bearing biomedical materials. The composites with 100 µm and 230 µm particle sizes exhibited Young's modulus of 37.6 GPa and 23.4 GPa, 500.7 MPa and 340 MPa of compressive strength and 631.5 MPa and 375.2 MPa of bending strength, respectively. Moreover, both of the modulus and strength of the composites increase with decreasing of Ti particle sizes. In vitro study has been done for the preliminary evaluation of the Ti-Mg composites.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Magnesium Alloys: Properties and Applications · Aluminum Alloys Composites Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. Balog, M., Snajdar, M., Krizik, P., Schauperl, Z., Stanec, Z., Catic, A., 2017. Titanium-magnesium composite for dental implants (BIACOM). In: TMS 2017 146th Annual Meeting & Exhibition Supplemental Proceedings, Springer, pp. 271–284.10.1007/978-3-319-51493-2_26 ↗
2. Crack propagation along grain boundaries and twins in Mg and Mg–0.3 at%Y alloy during in-situ straining in transmission electron microscope10.1016/j.scriptamat.2017.08.023 ↗
3. Influence of pore size of porous titanium fabricated by vacuum diffusion bonding of titanium meshes on cell penetration and bone ingrowth10.1016/j.actbio.2016.01.022 ↗
4. Metallic implant biomaterials10.1016/j.mser.2014.10.001 ↗
5. Processing of titanium foams10.1002/adem.200405576 ↗
6. Processing of titanium foams using magnesium spacer particles10.1016/j.scriptamat.2006.11.010 ↗
7. Titanium–magnesium based composites: mechanical properties and in-vitro corrosion response in Ringer's solution10.1016/j.msea.2013.02.040 ↗
8. A comparative study on biodegradation and mechanical properties of pressureless infiltrated Ti/Ti6Al4V–Mg composites10.1016/j.jmbbm.2016.06.026 ↗
9. Deformation mechanisms of spherical cell porous aluminum under quasi-static compression10.1016/j.scriptamat.2017.08.019 ↗
10. Ti based biomaterials, the ultimate choice for orthopaedic implants – a review10.1016/j.pmatsci.2008.06.004 ↗
11. Elastic deformation behaviour of Ti-24Nb-4Zr-7.9Sn for biomedical applications10.1016/j.actbio.2006.11.002 ↗
12. Development of ductile magnesium composite materials using titanium as reinforcement10.1016/S0925-8388(02)00413-9 ↗
13. Microstructurally inhomogeneous composites: is a homogeneous reinforcement distribution optimal?10.1016/j.pmatsci.2015.01.002 ↗
14. Biomedical materials and techniques to improve the tribological, mechanical and biomedical properties of orthopedic implants – a review article10.1016/j.jallcom.2017.04.231 ↗
15. Transmission electron microscopy investigation on dislocation bands in pure Mg10.1016/j.scriptamat.2016.11.035 ↗
16. Fabrication of graded porous titanium–magnesium composite for load-bearing biomedical applications10.1016/j.matdes.2014.12.001 ↗
17. Biocompatibility and compressive properties of Ti-6Al-4V scaffolds having Mg element10.1016/j.jmbbm.2015.04.015 ↗
18. Magnesium alloys for temporary implants in osteosynthesis: in vivo studies of their degradation and interaction with bone10.1016/j.actbio.2011.11.008 ↗
19. On the mechanism of {332} twinning in metastable β titanium alloys10.1016/j.actamat.2016.03.040 ↗
20. Experimentally quantifying critical stresses associated with basal slip and twinning in magnesium using micropillars10.1016/j.actamat.2017.06.008 ↗
21. Fabrication of continuous carbon fiber-reinforced aluminum–magnesium alloy composite wires using ultrasonic infiltration method10.1016/j.compositesa.2007.03.007 ↗
22. Phase diagrams of binary titanium alloys
23. A new Ti–15Zr–4Nb–4Taalloy for medical applications10.1016/S1359-0286(00)00025-5 ↗
24. Park · 2012
25. The use of titanium for medical applications in the USA10.1016/0921-5093(96)10243-4 ↗
26. Processing and mechanical properties of autogenous titanium implant materials10.1023/A:1014344819558 ↗
27. Formation of equiaxed α during ageing in a severely deformed metastable β Ti alloy10.1016/j.scriptamat.2016.07.012 ↗