Fracture strength and probability of survival of narrow and extra-narrow dental implants after fatigue testing: In vitro and in silico analysis
Source abstract
Abstract
PURPOSE: To assess the probability of survival (reliability) and failure modes of narrow implants with different diameters. MATERIALS AND METHODS: For fatigue testing, 42 implants with the same macrogeometry and internal conical connection were divided, according to diameter, as follows: narrow (Ø3.3×10mm) and extra-narrow (Ø2.9×10mm) (21 per group). Identical abutments were torqued to the implants and standardized maxillary incisor crowns were cemented and subjected to step-stress accelerated life testing (SSALT) in water. The use-level probability Weibull curves, and reliability for a mission of 50,000 and 100,000 cycles at 50N, 100, 150 and 180N were calculated. For the finite element analysis (FEA), two virtual models, simulating the samples tested in fatigue, were constructed. Loading at 50N and 100N were applied 30° off-axis at the crown. The von-Mises stress was calculated for implant and abutment. RESULTS: The beta (β) values were: 0.67 for narrow and 1.32 for extra-narrow implants, indicating that failure rates did not increase with fatigue in the former, but more likely were associated with damage accumulation and wear-out failures in the latter. Both groups showed high reliability (up to 97.5%) at 50 and 100N. A decreased reliability was observed for both groups at 150 and 180N (ranging from 0 to 82.3%), but no significant difference was observed between groups. Failure predominantly involved abutment fracture for both groups. FEA at 50N-load, Ø3.3mm showed higher von-Mises stress for abutment (7.75%) and implant (2%) when compared to the Ø2.9mm. CONCLUSIONS: There was no significant difference between narrow and extra-narrow implants regarding probability of survival. The failure mode was similar for both groups, restricted to abutment fracture.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Orthodontics and Dentofacial Orthopedics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (29)
Show source-provided references
1. Occlusal-supporting ability of individual maxillary and mandibular teeth10.1111/joor.12008 ↗
2. Dental implant length and diameter: a proposed classification scheme
3. The impact of loads on standard diameter, small diameter and mini implants: a comparative laboratory study10.1111/j.1600-0501.2007.01395.x ↗
4. Mechanical testing of implant-supported anterior crowns with different implant/abutment connections10.11607/jomi.2443 ↗
5. A prospective clinical study evaluating the safety and effectiveness of narrow-diameter threaded implants in the anterior region of the maxilla
6. Evaluation of 316 narrow diameter implants followed for 5-10 years: a clinical and radiographic retrospective study10.1111/j.1600-0501.2009.01840.x ↗
7. Dimensions of buccal bone and mucosa at immediately placed implants after 7 years: a clinical and cone beam computed tomography study10.1111/j.1600-0501.2011.02253.x ↗
8. Effects of implant diameter and prosthesis retention system on the reliability of single crowns10.11607/jomi.3545 ↗
9. A critical perspective on mechanical testing of implants and prostheses10.1177/0022034515624445 ↗
10. Fatigue failure of narrow implants with different implant-abutment connection designs
11. Implant therapy in a surgical specialty clinic: an analysis of patients, indications, surgical procedures, risk factors, and early failures10.11607/jomi.3769 ↗
12. Finite element stress analysis of dental prostheses supported by straight and angled implants
13. Finite element analysis of stress distribution at the tooth-denture base interface of acrylic resin teeth debonding from the denture base10.1016/S0022-3913(05)80310-5 ↗
14. Biomechanical evaluation of internal and external hexagon platform switched implant-abutment connections: an in vitro laboratory and three-dimensional finite element analysis10.1016/j.dental.2012.05.004 ↗
15. Clinical complications in fixed prosthodontics10.1016/S0022-3913(03)00214-2 ↗
16. Bite forces and their resultants during forceful intercuspal clenching in humans10.1016/j.jbiomech.2009.03.040 ↗
17. A systematic review of survival of single implants as presented in longitudinal studies with a follow-up of at least 10 years
18. Systematic review on success of narrow-diameter dental implants10.11607/jomi.2014suppl.g1.3 ↗
19. Implant-abutment connection designs for anterior crowns: reliability and failure modes10.1097/ID.0b013e31829f1f2d ↗
20. Implants (3.3mm diameter) for the rehabilitation of edentulous posterior regions: a retrospective clinical study with up to 11 years of follow-up10.1111/j.1708-8208.2009.00188.x ↗
21. Mechanics of the implant-abutment connection: an 8-degree taper compared to a butt joint connection
22. Complete band gaps in a polyvinyl chloride (PVC) phononic plate with cross-like holes: numerical design and experimental verification10.1016/j.ultras.2014.07.016 ↗
23. Narrow-diameter versus standard-diameter implants and their effect on the need for guided bone regeneration: a virtual three-dimensional study10.1111/cid.12224 ↗
24. A practical and systematic review of Weibull statistics for reporting strengths of dental materials10.1016/j.dental.2009.09.006 ↗
25. Predicting lifetimes of materials and material structures10.1016/0109-5641(95)80050-6 ↗
26. Critical horizontal dimensions of interproximal and buccal bone around implants for optimal aesthetic outcomes: a systematic review10.1111/j.1600-0501.2009.01782.x ↗
27. Assessment of mastication with implications for oral rehabilitation: a review10.1111/j.1365-2842.2010.02197.x ↗
28. Choosing or refusing oral implants: a prospective study of edentulous volunteers for a clinical trial
29. Clinical evaluation of small-diameter ITI implants: a prospective study