journal article·2016-01

Two-piece zirconia oral implants withstand masticatory loads: An investigation in the artificial mouth

Benedikt Christopher Spies, Julian Nold, Kirstin Vach, Ralf-Joachim Kohal

Publisher page

Abstract

Objective To evaluate the fracture resistance of two-piece zirconia oral implants after long-term thermomechanical cycling in an aqueous environment. Non-loaded samples and a one-piece implant system served as control groups. Methods A total of 48 zirconia implants were evaluated: 16 one-piece implants (ATZ; Group A) and 32 differently connected two-piece implants (16 screwed, Group B; 16 bonded, Group C) made of Y-TZP-A (implant+abutment; B) and Y-TZP-A/ATZ (implant/abutment; C), respectively. These groups were divided into two subgroups composed of 8 samples. The samples of subgroups 1 (A1, B1, C1) were not exposed to any cyclic loading, whereas subgroups 2 (A2, B2, C2) were loaded with 10 million cycles (98 N). Subsequently, all 48 implants were statically loaded to fracture. Results A constant load on distinct lever arms resulted in different exerted bending moments during the dynamic loading (A2: 23.4Ncm, B2: 17.9 Ncm, C2: 32.3 Ncm). All implants survived the long-term thermomechanical cycling. For the static loading the following average bending moments were calculated: A1/A2: 362/399 Ncm; B1/B2: 398/346 Ncm; C1/C2: 380/252 Ncm. Foregoing dynamic loading significantly increased fracture resistance of Group A implants, whereas Group B/C implants showed significantly decreased values. Potentially owed to the experimental setup in an aqueous environment of 60 °C, 5/8 C2 samples showed mobility between implant and abutment due to debonding after dynamic loading conditions. Significance The evaluated ceramic implant systems seem to be able to resist physiological chewing forces long-term. Within the limitations of the experimental setup, the connecting mechanism of Group C implants might be a weak point.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (48)

Show source-provided references
1. Implant survival and complications. The Third EAO consensus conference 201210.1111/j.1600-0501.2012.02557.x ↗
2. Osteointegration of bioactive glass-coated and uncoated zirconia in osteopenic bone: an in vivo experimental study10.1002/jbm.a.20057 ↗
3. Fracture strength of zirconia implants after artificial aging10.1111/j.1708-8208.2008.00105.x ↗
4. Are ceramic implants a viable alternative to titanium implants? A systematic literature review10.1111/j.1600-0501.2009.01785.x ↗
5. Intra-oral temperatures during function10.1111/j.1365-2842.2005.01509.x ↗
6. Zirconia dental implants: a clinical, radiographic, and microbiologic evaluation up to 3 years10.11607/jomi.3293 ↗
7. Immediate occlusal versus non-occlusal loading of single zirconia implants. A multicentre pragmatic randomised clinical trial
8. Low-temperature aging of Y-TZP ceramics10.1111/j.1151-2916.1999.tb02055.x ↗
9. Mechanical properties and short-term in-vivo evaluation of yttrium-oxide-partially-stabilized zirconia10.1002/jbm.820230105 ↗
10. Temperature dependence of rate constants
11. In vitro evaluation of the mutagenic and carcinogenic power of high purity zirconia ceramic10.1016/S0142-9612(98)00182-3 ↗
12. The wear of dental amalgam in an artificial mouth: a clinical correlation10.1016/S0109-5641(85)80050-6 ↗
13. Host response to titanium dental implant placement evaluated in a human oral model10.1902/jop.2006.050406 ↗
14. Biomechanical and histomorphometric comparison between zirconia implants with varying surface textures and a titanium implant in the maxilla of miniature pigs10.1111/j.1600-0501.2007.01401.x ↗
15. In vivo performance of zirconia and titanium implants: a histomorphometric study in mini pig maxillae10.1111/j.1600-0501.2011.02157.x ↗
16. Osseointegration of zirconia and titanium dental implants: a histological and histomorphometrical study in the maxilla of pigs10.1111/j.1600-0501.2009.01734.x ↗
17. Is titanium sensitivity associated with allergic reactions in patients with dental implants? A systematic review10.1111/j.1708-8208.2010.00330.x ↗
18. Phase transformation of zirconia ceramics by hydrothermal degradation10.4012/dmj.2010-175 ↗
19. Mechanical properties, phase stability, and biocompatibility of (Y, Nb)-TZP/Al(2)O(3) composite abutments for dental implant10.1002/1097-4636(2000)53:4<438::AID-JBM19>3.0.CO;2-3 ↗
20. Subcritical crack growth behavior of dispersion oxide ceramics10.1002/jbm.b.31703 ↗
21. Stability of prototype two-piece zirconia and titanium implants after artificial aging: an in vitro pilot study10.1111/j.1708-8208.2008.00116.x ↗
22. Three-dimensional computerized stress analysis of commercially pure titanium and yttrium-partially stabilized zirconia implants
23. Biomechanical and histological behavior of zirconia implants: an experiment in the rat10.1111/j.1600-0501.2008.01656.x ↗
24. Alumina-reinforced zirconia implants: survival rate and fracture strength in a masticatory simulation trial10.1111/j.1600-0501.2010.01954.x ↗
25. The effects of cyclic loading and preparation on the fracture strength of zirconium-dioxide implants: an in vitro investigation10.1111/j.1600-0501.2010.02067.x ↗
26. Low-temperature degradation of different zirconia ceramics for dental applications10.1016/j.actbio.2011.11.016 ↗
27. Zirconia in dentistry: Part 2. Evidence-based clinical breakthrough
28. Quality assessment of the cortical bone of the human mandible10.1016/S8756-3282(02)00921-3 ↗
29. In vivo forces on implants influenced by occlusal scheme and food consistency
30. Mechanical properties of biomedical titanium alloy10.1016/S0921-5093(97)00806-X ↗
31. Fractured zirconia implants and related implant designs: scanning electron microscopy analysis10.1111/j.1600-0501.2011.02411.x ↗
32. Zirconia as a ceramic biomaterial10.1016/S0142-9612(98)00010-6 ↗
33. In vivo horizontal bending moments on implants
34. The combined effect of alumina and silica co-doping on the ageing resistance of 3Y-TZP bioceramics10.1016/j.actbio.2014.09.009 ↗
35. A new testing protocol for zirconia dental implants10.1016/j.dental.2014.09.002 ↗
36. Low temperature degradation and reliability of one-piece ceramic oral implants with a porous surface10.1016/j.dental.2013.01.007 ↗
37. An alumina toughened zirconia composite for dental implant application: in vivo animal results
38. Mechanical anchorage and peri-implant bone formation of surface-modified zirconia in minipigs10.1111/j.1600-051X.2010.01549.x ↗
39. Low-temperature aging behavior of alumina-toughened zirconia10.1111/j.1551-2916.2008.02700.x ↗
40. Titanium allergy in dental implant patients: a clinical study on 1500 consecutive patients10.1111/j.1600-0501.2008.01544.x ↗
41. Titanium allergy: could it affect dental implant integration?10.1111/j.1600-0501.2010.02081.x ↗
42. Reliability of one-piece ceramic implant10.1002/jbm.b.31113 ↗
43. Alumina reinforced zirconia implants: effects of cyclic loading and abutment modification on fracture resistance10.1016/j.dental.2014.12.013 ↗
44. Alumina reinforced zirconia implants: 1-year results from a prospective cohort investigation
45. Impact of oral fluids on dental ceramics: what is the clinical relevance?10.1016/j.dental.2013.08.199 ↗
46. Etudes de dynamique chimique10.1002/recl.18840031003 ↗
47. Volpato, C.Â.M., Garbelotto, L.G.D., Fredel, M.C. and Bondioli, F., 2011. Application of zirconia in dentistry: biological, mechanical and optical considerations. In: Sikalidis, C. (Eds.), Advances in Ceramics – Electric and Magnetic Ceramics, Bioceramics, Ceramics and Environment, doi:10.5772/21630. Available open access from: 〈http://www.intechopen.com〉.
48. Hypersensitivity reactions to titanium: diagnosis and management10.1097/DER.0000000000000091 ↗