Diamond-like carbon coatings with zirconium-containing interlayers for orthopedic implants
Source abstract
Abstract
Six types of diamond-like carbon (DLC) coatings with zirconium (Zr)-containing interlayers on titanium alloy (Ti-6Al-4V) were investigated for improving the biotribological performance of orthopedic implants. The coatings consist of three layers: above the substrate a layer stack of 32 alternating Zr and ZrN sublayers (Zr:ZrN), followed by a layer comprised of Zr and DLC (Zr:DLC), and finally a N-doped DLC layer. The Zr:ZrN layer is designed for increasing load carrying capacity and corrosion resistance; the Zr:DLC layer is for gradual transition of stress, thus enhancing layer adhesion; and the N-doped DLC layer is for decreasing friction, squeaking noises and wear. Biotribological experiments were performed in simulated body fluid employing a ball-on-disc contact with a Si3N4 ball and a rotational oscillating motion to mimic hip motion in terms of gait angle, dynamic contact pressures, speed and body temperature. The results showed that the Zr:DLC layer has a substantial influence on eliminating delamination of the DLC from the substrates. The DLC/Si3N4 pairs significantly reduced friction coefficient, squeaking noise and wear of both the Si3N4 balls and the discs compared to those of the Ti-6Al-4V/Si3N4 pair after testing for a duration that is equivalent to one year of hip motion in vivo.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Diamond and Carbon-based Materials Research · Metal and Thin Film Mechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (47)
Show source-provided references
1. Aseptic loosening of total joint replacements: mechanisms underlying osteolysis and potential therapies10.1186/ar2170 ↗
2. High resolution study of the strong diamond/silicon nitride interface10.1063/1.3584019 ↗
3. Orthopedic applications of silicon nitride ceramics10.1016/j.actbio.2012.04.031 ↗
4. Testing of silicon nitride ceramic bearings for total hip arthroplasty10.1002/jbm.b.31123 ↗
5. Tribological performance of titanium doped and pure DLC coatings combined with a synthetic bio-lubricant10.1016/j.wear.2005.09.004 ↗
6. Development of DLC coating architectures for demanding functional surface applications through nano-and micro-mechanical testing10.1016/j.surfcoat.2015.05.050 ↗
7. Cohesive and adhesive failure of hard and brittle films on ductile metallic substrates: a film thickness size effect analysis of the model system hydrogenated diamond-like carbon (aC: h) on Ti substrates10.1016/j.actamat.2014.09.044 ↗
8. Future needs and challenges in tribo-corrosion research and testing
9. Risk of complication and revision total hip arthroplasty among Medicare patients with different bearing surfaces10.1007/s11999-010-1262-3 ↗
10. Canadian Joint Replacement Registry · 2015 · 2016
11. Mechanical properties and impact resistance of multilayered TiAlN/ZrN coatings10.1016/j.surfcoat.2012.03.013 ↗
12. Effects of surface coating on reducing friction and wear of orthopaedic implants10.1088/1468-6996/15/1/014402 ↗
13. A novel tribological study on DLC-coated micro-dimpled orthopedics implant interface10.1016/j.jmbbm.2014.11.028 ↗
14. Fabrication and characterization of DLC coated microdimples on hip prosthesis heads10.1002/jbm.b.33274 ↗
15. A novel functional layered diamond like carbon coating for orthopedics applications10.1016/j.diamond.2015.11.011 ↗
16. Improved wear resistance of functional diamond like carbon coated Ti–6Al–4V alloys in an edge loading conditions10.1016/j.jmbbm.2016.04.004 ↗
17. Donnet · 2007
18. Metal-on-metal hip joint tribology10.1243/095441105X69114 ↗
19. Tribological performance of the biological components of synovial fluid in artificial joint implants10.1088/1468-6996/16/4/045002 ↗
20. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements10.1243/0954411001535228 ↗
21. Diamond-like carbon coatings as biocompatible materials—an overview10.1016/S0925-9635(03)00018-9 ↗
22. An overview on diamond-like carbon coatings in medical applications10.1016/j.surfcoat.2013.04.015 ↗
23. Biological reactions to wear debris in total joint replacement10.1243/0954411001535219 ↗
24. Corrosion of a hip stem with a modular neck taper junction: a retrieval study of 16 cases10.1016/j.arth.2008.09.009 ↗
25. Prevalence of total hip and knee replacement in the United States10.2106/JBJS.N.01141 ↗
26. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 203010.2106/00004623-200704000-00012 ↗
27. The latest lessons learned from retrieval analyses of ultra-high molecular weight polyethylene, metal-on-metal, and alternative bearing total disc replacements10.1053/j.semss.2011.11.011 ↗
28. Tribology and micromechanics of chromium nitride based multilayer coatings on soft and hard substrates10.3390/coatings4010121 ↗
29. The role of the surface chemistry of CoCr alloy particles in the phagocytosis and DNA damage of fibroblast cells10.1002/jbm.a.31064 ↗
30. Diamond like carbon coatings for potential application in biological implants—a review10.1016/j.triboint.2012.09.006 ↗
31. Creep behavior and its influence on the mechanics of electrodeposited nickel films
32. Analysis of contact mechanics in ceramic-on-ceramic hip joint replacements10.1243/09544110260138718 ↗
33. Wear of CoCrMo alloys used in metal-on-metal hip joints: a tribocorrosion appraisal10.1016/j.wear.2012.11.061 ↗
34. Influence of different counterfaces on tribological behaviors of Al2O3 nanocomposites for joint prostheses10.2474/trol.4.127 ↗
35. Taper design affects failure of large-head metal-on-metal total hip replacements10.1007/s11999-013-3115-3 ↗
36. Wear debris characterization and corresponding biological response: artificial hip and knee joints10.3390/ma7020980 ↗
37. Quantitative assessment of walking activity after total hip or knee replacement10.2106/00004623-199801000-00010 ↗
38. Shigley · 2011
39. Smith, A.J., Dieppe, P., Porter, M., Blom, A.W., 2012. Risk of Cancer In First Seven Years After Metal-on-metal Hip Replacement Compared With Other Bearings and General Population: Linkage Study Between The National Joint Registry of England and Wales and hospital episode statistics.10.1136/bmj.e2383 ↗
40. Stachowiak · 2013
41. Friction and wear behavior of titanium nitride, zirconium nitride and chromium nitride coatings at elevated temperatures10.1016/0257-8972(95)02506-5 ↗
42. Long-term implant fixation and stress-shielding in total hip replacement10.1016/j.jbiomech.2014.12.021 ↗
43. Designing, processing and characterisation of titanium cylinders with graded porosity: an alternative to stress-shielding solutions10.1016/j.matdes.2014.06.012 ↗
44. The influence of Zr layer thickness on contact deformation and fracture in a ZrN–Zr multilayer coating10.1007/s10853-011-6001-y ↗
45. Sliding properties of Zr-DLC coatings: the effect of tribolayer formation10.1016/j.surfcoat.2014.08.003 ↗
46. Tribo-corrosion of coatings: a review10.1088/0022-3727/40/18/S10 ↗
47. Contact damage failure analyses of fretting wear behavior of the metal stem titanium alloy–bone cement interface10.1016/j.jmbbm.2015.06.025 ↗