journal article·2011-10

Compressive behaviour of bovine cancellous bone and bone analogous materials, microCT characterisation and FE analysis

T. Guillén, Q.-H. Zhang, G. Tozzi, A. Ohrndorf, H.-J. Christ, J. Tong

Publisher page

Abstract

Compressive behaviour of bovine cancellous bone and three open-cell metallic foams (AlSi7Mg (30 ppi and 45 ppi); CuSn12Ni2 (30 ppi)) has been studied using mechanical testing, micro-focus computed tomography and finite element modelling. Whilst the morphological parameters of the foams and the bone appear to be similar, the mechanical properties vary significantly between the foams and the bone. Finite element models were built from the CT images of the samples and multi-linear constitutive relations were used for modelling of the bone and the foams. The global responses of the bone and foam samples were reasonably well captured by the FE models, whilst the percentage of yielded elements as a measure of damage evolution during compression seems to be indicative of the micro-mechanical behaviour of the samples. The damage evolution and distribution patterns across the bone and the foams are broadly similar for the strain range studied, suggesting possible substitution of trabecular bones with appropriate foams for biomechanical studies.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Cellular and Composite Structures · Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (47)

Show source-provided references
1. Microstructure-based finite element modelling and characterisation of bovine trabecular bone10.1016/S1672-6529(06)60001-2 ↗
2. Compressive and tensile behaviour of aluminum foams10.1016/S0921-5093(99)00170-7 ↗
3. High-porosity and alloys in catalytic processes of gas cleaning10.1002/adem.200400132 ↗
4. Mechanical properties of cellular solids10.1007/BF02645546 ↗
5. Deformation characteristics of metal foams10.1023/A:1004383222228 ↗
6. Trabecular bone strength predictions using finite element analysis of micro-scale images at limited spatial resolution10.1016/j.bone.2008.11.020 ↗
7. British Standard. BS EN 1982, 1999. Copper and copper alloys. Ingots and castings.
8. The compressive behavior of bone as a two-phase porous structure10.2106/00004623-197759070-00021 ↗
9. Variations in three-dimensional cancellous bone architecture of the proximal femur in female hip fractures and in controls10.1359/jbmr.2000.15.1.32 ↗
10. DIN 50134. 2008. Testing of metallic materials — Compression test of metallic cellular materials Deutsches Institut Fur Normung E.V. (German National Standard).
11. Technical note. Accuracy of cancellous bone volume fraction measured by micro-CT scanning10.1016/S0021-9290(98)00176-6 ↗
12. Multifunctionality of cellular metal systems10.1016/S0079-6425(98)00004-8 ↗
13. Biomechanics of cellular solids10.1016/j.jbiomech.2004.09.027 ↗
14. Gibson · 1988
15. Gibson · 1997
16. Failure surfaces for cellular materials under multiaxial loads. I. Modelling10.1016/S0020-7403(89)80001-3 ↗
17. Open pore metal foams for heat exchange in ventilation and refrigeration
18. The mechanical properties of trabecular bone: dependence on anatomic location and function10.1016/0021-9290(87)90023-6 ↗
19. Trabecular bone modulus and strength can depend on specimen geometry10.1016/0021-9290(93)90059-N ↗
20. A 20-year perspective on the mechanical properties of trabecular bone10.1115/1.2895536 ↗
21. Differences between the tensile and compressive strengths of bovine tibial trabecular bone depend on modulus10.1016/0021-9290(94)90054-X ↗
22. Application of the Tsai-Wu quadratic multiaxial failure criterion to bovine trabecular bone10.1115/1.2798051 ↗
23. Biomechanics of trabecular bone10.1146/annurev.bioeng.3.1.307 ↗
24. Systematic and random errors in compression testing of trabecular bone10.1002/jor.1100150115 ↗
25. How useful is SBF in predicting in vivo bone bioactivity?10.1016/j.biomaterials.2006.01.017 ↗
26. Isothermal and thermomechanical fatigue behavior of open-cell metal sponges10.1002/adem.200600081 ↗
27. Composition and mechanical properties of cancellous bone from the femoral head of patients with osteoporosis or osteoarthritis10.1359/jbmr.1997.12.4.641 ↗
28. The effect of specimen geometry on the mechanical behavior of trabecular bone specimens10.1016/0021-9290(92)90255-Y ↗
29. The effect of different storage methods on the mechanical properties of trabecular bone10.1016/0021-9290(93)90072-M ↗
30. Elastic and viscoelastic properties of trabecular bone by a compression testing approach
31. Analysis of crack growth in a 3D Voronoi structure: a model for fatigue in low density trabecular bone10.1115/1.1503792 ↗
32. Martin · 1998
33. Time-lapsed microstructural imaging of bone failure behavior10.1016/S0021-9290(03)00254-9 ↗
34. Design and implementation of a novel mechanical testing system for cellular solids10.1002/jbm.b.30232 ↗
35. The interaction of microstructure and volume fraction in predicting failure in cancellous bone10.1016/j.bone.2006.06.013 ↗
36. Structural and material mechanical properties of human vertebral cancellous bone10.1016/S1350-4533(97)00030-1 ↗
37. High-resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone10.1016/S0021-9290(00)00149-4 ↗
38. Ohrndorf, A., Krupp, U., Christ, H.-J., 2005. Correlation between fracture behaviour and ductility of the cell strut material in case of metallic foams, In: 11th International Conference on Fracture — ICF11, Turin, Italien, pp. 4340–4345.
39. Metallic open-cell foams — A promising approach to fabricating good medical implants10.3233/THC-2006-144-502 ↗
40. Structure and properties of Al–SiC foam10.1016/0921-5093(94)09708-9 ↗
41. Characterization of the deformation behavior of intermediate porosity interconnected Ti foams using micro-computed tomography and direct finite element modeling10.1016/j.actbio.2009.11.032 ↗
42. Fatigue and fatigue crack propagation in AISi7Mg cast alloys under in-service loading conditions10.1016/0142-1123(95)95895-N ↗
43. A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models10.1016/0021-9290(95)80008-5 ↗
44. Micro-finite element simulation of trabecular-bone post-yield behaviour—effects of material model, element size and type10.1080/10255840701848756 ↗
45. Weber, M., Baumeister, J., Banhart, J., Kunze, H.-D., 1994. Selected mechanical and physical properties of metal foams. In: PM94 Proceedings of the Powder Metallurgy World Congress, Paris, France, pp. 585–588.
46. Relative roles of microdamage and microfracture in the mechanical behavior of trabecular bone10.1016/S0736-0266(01)00053-5 ↗
47. Finite element modelling of the actual structure of cellular materials determined by X-ray tomography10.1016/j.actamat.2004.10.024 ↗