Abstract

Computational modeling has an important role in design and assessment of medical devices. In computational simulations, considering accurate constitutive models is of the utmost importance to capture mechanical response of soft tissue and biomedical materials under physiological loading conditions. Lack of comprehensive three-dimensional constitutive models for soft tissue limits the effectiveness of computational modeling in research and development of medical devices. The aim of this study was to use inverse finite element (FE) analysis to determine three-dimensional mechanical properties of bovine pericardial leaflets of a surgical bioprosthesis under dynamic loading condition. Using inverse parameter estimation, 3D anisotropic Fung model parameters were estimated for the leaflets. The FE simulations were validated using experimental in-vitro measurements, and the impact of different constitutive material models was investigated on leaflet stress distribution. The results of this study showed that the anisotropic Fung model accurately simulated the leaflet deformation and coaptation during valve opening and closing. During systole, the peak stress reached to 3.17MPa at the leaflet boundary while during diastole high stress regions were primarily observed in the commissures with the peak stress of 1.17MPa. In addition, the Rayleigh damping coefficient that was introduced to FE simulations to simulate viscous damping effects of surrounding fluid was determined.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Cardiac Valve Diseases and Treatments · Elasticity and Material Modeling · Tribology and Lubrication Engineering

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (41)

Show source-provided references
1. Leaflet stress and strain distributions following incomplete transcatheter aortic valve expansion10.1016/j.jbiomech.2015.08.012 ↗
2. Biaxial mechanical properties of the natural and glutaraldehyde treated aortic valve cusp – part I: experimental results10.1115/1.429624 ↗
3. Strain uniformity in biaxial specimens is highly sensitive to attachment details10.1115/1.3148467 ↗
4. Fung · 2001
5. Fung · 2013
6. Pseudoelasticity of arteries and the choice of its mathematical expression
7. Holzapfel · 2000
8. On planar biaxial tests for anisotropic nonlinearly elastic solids. A continuum mechanical framework
9. Fluid–structure interaction analysis of bioprosthetic heart valves: significance of arterial wall deformation10.1007/s00466-014-1059-4 ↗
10. Dynamic and fluid–structure interaction simulations of bioprosthetic heart valves using parametric design with T-splines and Fung-type material models
11. Biaxial mechanical behavior of excised ventricular epicardium10.1152/ajpheart.1990.259.1.H101 ↗
12. Mechanics of the arterial wall: review and directions10.1615/CritRevBiomedEng.v23.i1-2.10 ↗
13. Continuum biomechanics of soft biological tissues10.1098/rspa.2002.1060 ↗
14. Effect of geometry on the leaflet stresses in simulated models of congenital bicuspid aortic valves10.1007/s13239-011-0035-9 ↗
15. An immersogeometric variational framework for fluid–structure interaction: application to bioprosthetic heart valves10.1016/j.cma.2014.10.040 ↗
16. Mechanical characterisation of polyurethane elastomer for biomedical applications10.1016/j.jmbbm.2009.03.005 ↗
17. A Process for design, verification, validation, and manufacture of medical devices using immersive VR environments
18. Emerging trends in heart valve engineering: part IV. computational modeling and experimental studies10.1007/s10439-015-1394-4 ↗
19. Emerging trends in heart valve engineering: part II. novel and standard technologies for aortic valve replacement10.1007/s10439-014-1191-5 ↗
20. An experimentally derived stress resultant shell model for heart valve dynamic simulations10.1007/s10439-006-9203-8 ↗
21. Dynamic simulation of bioprosthetic heart valves using a stress resultant shell model10.1007/s10439-007-9409-4 ↗
22. Multi-objective particle swarm optimization: an introduction10.6029/smartcr.2014.05.001 ↗
23. Introduction to continuum mechanics
24. Lee, J.M., Haberer, S.A., Pereira, C.A., Naimark, W.A., Courtman, D.W., Wilson, G.J., 1994. High strain rate testing and structural analysis of pericardial bioprosthetic materials, Biomaterials׳ Mechanical Properties. ASTM Special Technical Publication 1173, 19-19.10.1520/STP18091S ↗
25. Dynamic mechanical characteristics of intact and structurally modified bovine pericardial tissues10.1016/j.jbiomech.2004.05.019 ↗
26. On the correct interpretation of measured force and calculation of material stress in biaxial tests10.1016/j.jmbbm.2015.08.019 ↗
27. Can analysis of transmitral flow–velocity contours differentiate between alternative diastolic pressure–volume relations?10.1023/A:1020981303354 ↗
28. A comparative study of linear and nonlinear simulations of the leaflets in a bioprosthetic heart valve during the cardiac cycle10.3109/03091909609008387 ↗
29. A method for planar biaxial mechanical testing that includes in-plane shear10.1115/1.2835086 ↗
30. Biaxial mechanical evaluation of planar biological materials
31. Orthotropic mechanical properties of chemically treated bovine pericardium10.1114/1.135 ↗
32. Collagen fiber architecture of bovine pericardium10.1097/00002480-199407000-00075 ↗
33. Evaluation of a particle swarm algorithm for biomechanical optimization10.1115/1.1894388 ↗
34. Parallel global optimization with the particle swarm algorithm10.1002/nme.1149 ↗
35. Results of fda׳s first interlaboratory computational study of a nozzle with a sudden contraction and conical diffuser10.1007/s13239-013-0166-2 ↗
36. Simulated bioprosthetic heart valve deformation under quasi-static loading10.1115/1.2049337 ↗
37. Finite element implementation of a generalized Fung-elastic constitutive model for planar soft tissues10.1007/s10237-005-0075-x ↗
38. The extension rate independence of the hysteresis in glutaraldehyde-fixed bovine pericardium10.1016/0142-9612(87)90064-0 ↗
39. Boundary conditions during biaxial testing of planar connective tissues part II fiber orientation10.1023/A:1016576603938 ↗
40. Effect of sample geometry on the apparent biaxial mechanical behaviour of planar connective tissues10.1016/j.biomaterials.2005.05.056 ↗
41. Mechanical and optical anisotropy of bovine pericardium10.1007/BF02446197 ↗