Deformation and fatigue of tough 3D printed elastomer scaffolds processed by fused deposition modeling and continuous liquid interface production
Source abstract
Abstract
Polyurethane (PU) based elastomers continue to gain popularity in a variety of biomedical applications as compliant implant materials. In parallel, advancements in additive manufacturing continue to provide new opportunities for biomedical applications by enabling the creation of more complex architectures for tissue scaffolding and patient specific implants. The purpose of this study was to examine the effects of printed architecture on the monotonic and cyclic mechanical behavior of elastomeric PUs and to compare the structure-property relationship across two different printing approaches. We examined the tensile fatigue of notched specimens, 3D crosshatch scaffolds, and two 3D spherical pore architectures in a physically crosslinked polycarbonate urethane (PCU) printed via fused deposition modeling (FDM) as well as a photo-cured, chemically-crosslinked, elastomeric PU printed via continuous liquid interface production (CLIP). Both elastomers were relatively tolerant of 3D geometrical features as compared to stiffer synthetic implant materials such as PEEK and titanium. PCU and crosslinked PU samples with 3D porous structures demonstrated a reduced tensile failure stress as expected without a significant effect on tensile failure strain. PCU crosshatch samples demonstrated similar performance in strain-based tensile fatigue as solid controls; however, when plotted against stress amplitude and adjusted by porosity, it was clear that the architecture had an impact on performance. Square shaped notches or pores in crosslinked PU appeared to have a modest effect on strain-based tensile fatigue while circular shaped notches and pores had little impact relative to smooth samples. When plotted against stress amplitude, any differences in fatigue performance were small or not statistically significant for crosslinked PU samples. Despite the slight difference in local architecture and tolerances, crosslinked PU solid samples were found to perform on par with PCU solid samples in tensile fatigue, when appropriately adjusted for material hardness. Finally, tests of samples with printed architecture localized to the gage section revealed an effect in which fatigue performance appeared to drastically improve despite the localization of strain.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Additive Manufacturing and 3D Printing Technologies · 3D Printing in Biomedical Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (56)
Show source-provided references
1. Rupture propagation in hysteresial materials: stress at a notch10.1016/0022-5096(63)90009-7 ↗
2. Evaluating the statistical significance of a fatigue-life reduction due to macro-porosity10.5545/sv-jme.2013.1453 ↗
3. Balazs, C., 1964. Mechanical design and notch sensitivity of molding materials., DTIC Documen.
4. Scaffold design and in vitro study of osteochondral coculture in a three-dimensional porous polycaprolactone scaffold fabricated by fused deposition modeling10.1089/10763270360697012 ↗
5. Investigation of the mechanical properties and porosity relationships in fused deposition modelling-fabricated porous structures10.1108/13552540610652447 ↗
6. Biodegradation mechanisms of polyurethane elastomers10.1179/174327807X238909 ↗
7. Fatigue properties of carbon‐and porous‐coated Ti-6Al-4V alloy10.1002/jbm.820180504 ↗
8. The effect of post‐sintering heat treatments on the fatigue properties of porous coated Ti‐6Al‐4V Alloy10.1002/jbm.820220404 ↗
9. Effect of process parameters on the morphological and mechanical properties of 3D bioextruded poly (ϵ-caprolactone) scaffolds10.1108/13552541211193502 ↗
10. Microspheres leaching for scaffold porosity control
11. Wear rate evaluation of a novel polycarbonate-urethane cushion form bearing for artificial hip joints10.1016/j.actbio.2010.07.011 ↗
12. High-strength, surface-porous polyether-ether-ketone for load-bearing orthopedic implants10.1016/j.actbio.2014.11.030 ↗
13. Evans, N.T., 2016. Processing-structure-property relationships of surface porous polymers for orthopaedic applications.
14. What would surgeons like from materials scientists?
15. Porous scaffold design for tissue engineering10.1038/nmat1421 ↗
16. Monotonic and cyclic loading behavior of porous scaffolds made from poly (para-phenylene) for orthopedic applications10.1016/j.jmbbm.2014.10.004 ↗
17. Compression‐compression fatigue of selective electron beam melted cellular titanium (Ti‐6Al‐4V)10.1002/jbm.b.31901 ↗
18. Scaffolds in tissue engineering bone and cartilage10.1016/S0142-9612(00)00121-6 ↗
19. Mechanical properties and cell cultural response of polycaprolactone scaffolds designed and fabricated via fused deposition modeling10.1002/1097-4636(200105)55:2<203::AID-JBM1007>3.0.CO;2-7 ↗
20. The use of polyurethane materials in the surgery of the spine: a review10.1016/j.spinee.2014.08.012 ↗
21. Development of controlled porosity polymer-ceramic composite scaffolds via fused deposition modeling10.1016/S0928-4931(03)00052-3 ↗
22. Static and dynamic fatigue behavior of topology designed and conventional 3D printed bioresorbable PCL cervical interbody fusion devices10.1016/j.jmbbm.2015.05.015 ↗
23. A parametric study of the factors affecting the fatigue strength of porous coated Ti‐6A1‐4V implant alloy10.1002/jbm.820241106 ↗
24. Biodegradable and bioactive porous scaffold structures prepared using fused deposition modeling10.1002/jbm.b.32863 ↗
25. Lamba · 1997
26. Biodegradable polycaprolactone scaffold with controlled porosity obtained by modified particle-leaching technique
27. 3D printing of composite tissue with complex shape applied to ear regeneration10.1088/1758-5082/6/2/024103 ↗
28. Compression fatigue behavior of Ti–6Al–4V mesh arrays fabricated by electron beam melting10.1016/j.actamat.2011.10.051 ↗
29. McNamara, J., 2011. Novel approaches to the analysis of localised stress concentrations in deformed elastomers, 2011.
30. Prosthetic meshes for repair of hernia and pelvic organ prolapse: comparison of biomechanical properties10.3390/ma8052794 ↗
31. Compressive cyclic ratcheting and fatigue of synthetic, soft biomedical polymers in solution10.1016/j.jmbbm.2015.09.034 ↗
32. Fatigue of injection molded and 3D printed polycarbonate urethane in solution10.1016/j.polymer.2016.11.055 ↗
33. 3D fiber-deposited scaffolds for tissue engineering: influence of pores geometry and architecture on dynamic mechanical properties10.1016/j.biomaterials.2005.07.023 ↗
34. Printing three-dimensional tissue analogues with decellularized extracellular matrix bioink
35. Influence of processing conditions on the multiphase structure of segmented polyurethane10.1016/S0032-3861(97)10350-0 ↗
36. Understanding the biodegradation of polyurethanes: from classical implants to tissue engineering materials10.1016/j.biomaterials.2005.05.079 ↗
37. Comparison of the mechanical properties between tantalum and nickel–titanium foams implant materials for bone ingrowth applications10.1016/j.jallcom.2006.08.069 ↗
38. Development of a hybrid scaffold with synthetic biomaterials and hydrogel using solid freeform fabrication technology10.1088/1758-5082/3/3/034102 ↗
39. Bioprinting of a mechanically enhanced three-dimensional dual cell-laden construct for osteochondral tissue engineering using a multi-head tissue/organ building system10.1088/0960-1317/22/8/085014 ↗
40. A tribological study of UHMWPE acetabular cups and polyurethane compliant layer acetabular cups10.1002/1097-4636(2000)53:6<710::AID-JBM14>3.0.CO;2-R ↗
41. Polyurethane elastomer biostability10.1177/088532829500900402 ↗
42. The notch sensitivity of polymeric materials10.1002/app.1976.070200814 ↗
43. Fabrication of channeled scaffolds with ordered array of micro-pores through microsphere leaching and indirect rapid prototyping technique10.1007/s10544-012-9690-3 ↗
44. Treharne, R.W., Greene, A., 2008. The case for the use of polycarbonate-urethane in orthopedic implants, Med-Tech, Spring, 1, pp. 18–22.
45. Porous scaffold performance for foot and ankle applications: material and shape as predictors for fracture
46. West, M. et al., Using Polyurethanes in Medical Applications.
47. Cut growth and fatigue properties of cellular polyurethane elastomers10.1002/app.1974.070180813 ↗
48. Bone tissue engineering using polycaprolactone scaffolds fabricated via selective laser sintering10.1016/j.biomaterials.2004.11.057 ↗
49. Effect of a change in interfacial geometry on the fatigue strength of porous‐coated Ti‐6Al‐4V10.1002/jbm.820280403 ↗
50. Design of porous scaffolds for cartilage tissue engineering using a three-dimensional fiber-deposition technique10.1016/j.biomaterials.2003.10.056 ↗
51. Fatigue behavior of porous biomaterials manufactured using selective laser melting10.1016/j.msec.2013.08.006 ↗
52. Relationship between unit cell type and porosity and the fatigue behavior of selective laser melted meta-biomaterials10.1016/j.jmbbm.2014.12.015 ↗
53. The fatigue strength of porous‐coated Ti–6% Al–4% V implant alloy10.1002/jbm.820180908 ↗
54. Structure, metallurgy, and mechanical properties of a porous tantalum foam10.1002/1097-4636(2001)58:2<180::AID-JBM1005>3.0.CO;2-5 ↗
55. Biomedical applications of polyurethanes: a review of past promises, present realities, and a vibrant future10.1177/088532829901400104 ↗
56. Fused deposition modeling of novel scaffold architectures for tissue engineering applications10.1016/S0142-9612(01)00232-0 ↗