journal article·2014-08

The relation between hydration and mechanical behavior of bovine cornea in tension

Hamed Hatami-Marbini, Abdolrasol Rahimi

Publisher page

Abstract

The cornea is a transparent soft tissue covering the front of the eye. The biomechanical properties of the cornea have been commonly investigated by uniaxial tensile and inflation testing methods. The cornea like many other hydrated tissue swells when immersed in an ionic solution. Previous studies on hydrated tissues have shown that mechanical properties and hydration are closely related. The present study was designed to investigate the effects of thickness (hydration) variation due to swelling/dehydration on non-linear stress-strain response of the bovine cornea. Corneal strips were first air-dried and then soaked in a bathing solution until they reached an average thickness ranging from 0.3mm to 1.1mm. Based on their thickness, the samples were divided into different groups and uniaxial tests were performed to measure tensile properties. All experiments were done in mineral oil to prevent any hydration gain or loss during the tests. It was observed that swollen corneas had softer tensile properties in comparison with dehydrated ones. In particular, there was a significant difference between elastic tangent modulus of different groups (P<0.05). It was also shown that tensile behavior of bovine strips at any thickness within the range of 0.4-1.1mm can be obtained from a single experiment conducted on samples with known thickness (hydration). The findings of the present study confirm that mechanical properties obtained from uniaxial tensile experiments are strongly dependent on thickness (water amount) of samples; therefore, careful attention must be taken in interpreting previous studies which did not fully control the thickness of specimens.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Corneal surgery and disorders · Corneal Surgery and Treatments · Ocular Surface and Contact Lens

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (29)

Show source-provided references
1. Mechanical characterization of porcine corneas10.1115/1.4006089 ↗
2. Stress-controlled viscoelastic tensile response of bovine cornea10.1016/j.jbiomech.2006.12.001 ↗
3. Modeling collagen–proteoglycanstructural interactions in the human cornea
4. Mechanical anisotropy of porcine cornea and correlation with stromal microstructure10.1016/j.exer.2009.01.010 ↗
5. Comparative study of corneal strip extensometry and inflation tests10.1098/rsif.2005.0034 ↗
6. Strain-rate sensitivity of porcine and ovine corneas
7. Foster · 2005
8. Structural transformation of collagen fibrils in corneal stroma during drying. An X-ray scattering study10.1016/S0006-3495(93)81487-5 ↗
9. The molecular basis of corneal transparency10.1016/j.exer.2010.06.021 ↗
10. Mechano-electrochemical mixture theories for the multiphase fluid infiltrated poroelastic media
11. The viscoelastic shear properties of the corneal stroma10.1016/j.jbiomech.2013.11.019 ↗
12. Hydration dependent biomechanical properties of the corneal stroma10.1016/j.exer.2013.07.016 ↗
13. Swelling pressure and hydration behavior of porcine corneal stroma10.3109/02713683.2013.809769 ↗
14. Hatami-Marbini, H., Pinsky, P.M., 2009. On mechanics of connective tissue: assessing the electrostatic contribution to corneal stroma elasticity. In: Material Reseaech Society Proceedings. Boston, p. 1239.10.1557/PROC-1239-VV03-07 ↗
15. Effects of bathing solution on tensile properties of the cornea10.1016/j.exer.2013.11.017 ↗
16. The thickness–hydration relationship of the cornea10.1016/S0014-4835(66)80010-6 ↗
17. In vitro measurement of corneal strain, thickness, and curvature using digital image processing10.1111/j.1600-0420.1995.tb00004.x ↗
18. Why the cornea swells10.1016/0022-5193(71)90090-7 ↗
19. Strip extensiometry for comparison of the mechanical response of bovine, rabbit, and human corneas10.1115/1.2891373 ↗
20. Scleral mechanics: comparing whole globe inflation and uniaxial testing10.1016/j.exer.2011.11.017 ↗
21. The cornea and sclera
22. Variation of corneal refractive index with hydration10.1088/0031-9155/49/5/015 ↗
23. Proteoglycan: collagen interactions and corneal ultrastructure10.1042/bst0190877 ↗
24. The influence of swelling and matrix degradation on the microstructural integrity of tendon10.1016/j.actbio.2006.05.008 ↗
25. Proteoglycans in the eye10.1097/01.ico.0000263121.45898.d2 ↗
26. Altering ligament water content affects ligament pre-stress and creep behaviour10.1016/S0736-0266(01)00005-5 ↗
27. Mechanical characterization of skin-finite deformations10.1016/0021-9290(70)90055-2 ↗
28. Stress–strain measurements of human and porcine corneas after riboflavin–ultraviolet-A-induced cross-linking10.1016/S0886-3350(03)00407-3 ↗
29. Nonlinear material properties of intact cornea and sclera10.1016/0014-4835(72)90139-X ↗