journal article·2014-10

Biaxial analysis of synthetic scaffolds for hernia repair demonstrates variability in mechanical anisotropy, non-linearity and hysteresis

Corey R. Deeken, Dominic M. Thompson, Ryan M. Castile, Spencer P. Lake

Publisher page

Abstract

Background Over the past 60 years, the soft tissue repair market has grown to include over 50 types of hernia repair materials. Surgeons typically implant these materials in the orientation that provides maximum overlap of the mesh over the defect, with little regard for mechanical properties of the mesh material. If the characteristics of the meshes were better understood, an appropriate material could be identified for each patient, and meshes could be placed to optimize integration with neighboring tissue and avoid the mechanical mis-match that can lead to impaired graft fixation. The purpose of this study was to fully characterize and compare the mechanical properties of thirteen types of hernia repair materials via planar biaxial tensile testing. Methods Equibiaxial (i.e., equal simultaneous loading in both directions) and strip biaxial (i.e., loading in one direction with the other direction held fixed) tests were utilized as physiologically relevant loading regimes. After applying a 0.1N pre-load on each arm, samples were subjected to equibiaxial cyclic loading using a triangular waveform to 2.5mm displacement on each arm at 0.1Hz for 10 cycles. Samples were then subjected to two strip biaxial tests (using the same cyclic loading protocol), where extension was applied along a single axis with the other axis held fixed. Results The thirteen evaluated mesh types exhibited a wide range of mechanical properties. Some were nearly isotropic (C-QUR™, DUALMESH(®), PHYSIOMESH™, and PROCEED(®)), while others were highly anisotropic (Ventralight™ ST, Bard™ Mesh, and Bard™ Soft Mesh). Some displayed nearly linear behavior (Bard™ Mesh), while others were non-linear with a long toe region followed by a sharp rise in tension (INFINIT(®)). These materials are currently utilized in clinical settings as if they are uniform and interchangeable, and clearly this is not the case. The mechanical properties most advantageous for successful hernia repairs are currently only vaguely described in the clinical literature. The characteristics of the human abdominal wall must be extensively characterized to provide a thorough understanding of the tissue being reinforced/replaced by these meshes. A better understanding of these mechanical differences would enable matching of patient characteristics to a specific mesh with the properties best suited to that particular repair.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Hernia repair and management · Orthopaedic implants and arthroplasty · Intestinal and Peritoneal Adhesions

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (20)

Show source-provided references
1. Cobb W., Carbonell A., Novitsky Y., Matthews B., 2009. Central mesh failure with lightweight mesh: a cautionary note. In: Presented at the European Hernia Society Meeting. Berlin, Germany.
2. Characterization of the mechanical strength, resorption properties, and histologic characteristics of a fully absorbable material (Poly-4-hydroxybutyrate-PHASIX Mesh) in a porcine model of hernia repair
3. Physicomechanical evaluation of absorbable and nonabsorbable barrier composite meshes for laparoscopic ventral hernia repair10.1007/s00464-010-1432-0 ↗
4. Physicomechanical evaluation of polypropylene, polyester, and polytetrafluoroethylene meshes for inguinal hernia repair10.1016/j.jamcollsurg.2010.09.012 ↗
5. Differentiation of biologic scaffold materials through physicomechanical, thermal, and enzymatic degradation techniques10.1097/SLA.0b013e3182445341 ↗
6. A review of the composition, characteristics, and effectiveness of barrier mesh prostheses utilized for laparoscopic ventral hernia repair10.1007/s00464-011-1899-3 ↗
7. Development of novel electrospun absorbable polycaprolactone (PCL) scaffolds for hernia repair applications10.1007/s00464-012-2258-8 ↗
8. Forces and deformations of the abdominal wall—a mechanical and geometrical approach to the linea alba10.1016/j.jbiomech.2010.11.021 ↗
9. Anisotropy of human linea alba: a biomechanical study10.1016/j.jss.2004.10.010 ↗
10. Measurement of the tensile strength of the ventral abdominal wall in comparison with scar tissue10.1016/j.clinbiomech.2006.06.002 ↗
11. Biomechanik der Bauchdecke
12. Experimental study of the mechanical properties of human abdominal fascia10.1016/j.medengphy.2010.07.017 ↗
13. Matrix mechanical properties of transversalis fascia in inguinal herniation as a model for tissue expansion10.1016/j.jbiomech.2008.08.018 ↗
14. Mechanical characterisation of porcine rectus sheath under uniaxial and biaxial tension
15. Mechanical characterization and constitutive modelling of the damage process in rectus sheath10.1016/j.jmbbm.2011.12.005 ↗
16. Millennium Research Group, US Markets for Soft Tissue Repair Devices, 2006. Toronto, Ontario, Canada: Millennium Research Group, Inc.
17. A non-biological model system to simulate the in vivo mechanical behavior of prosthetic meshes10.1016/j.jmbbm.2013.01.029 ↗
18. Combined biaxial and uniaxial mechanical characterization of prosthetic meshes in a rabbit model
19. Use of marlex mesh in the repair of incisional hernias
20. Polypropylene surgical mesh coated with extracellular matrix mitigates the host foreign body response