The influence of intraocular pressure and air jet pressure on corneal contactless tonometry tests
Source abstract
Abstract
The air puff is a dynamic contactless tonometer test used in ophthalmology clinical practice to assess the biomechanical properties of the human cornea and the intraocular pressure due to the filling fluids of the eye. The test is controversial, since the dynamic response of the cornea is governed by the interaction of several factors which cannot be discerned within a single measurement. In this study we describe a numerical model of the air puff tests, and perform a parametric analysis on the major action parameters (jet pressure and intraocular pressure) to assess their relevance on the mechanical response of a patient-specific cornea. The particular cornea considered here has been treated with laser reprofiling to correct myopia, and the parametric study has been conducted on both the preoperative and postoperative geometries. The material properties of the cornea have been obtained by means of an identification procedure that compares the static biomechanical response of preoperative and postoperative corneas under the physiological IOP. The parametric study on the intraocular pressure suggests that the displacement of the cornea׳s apex can be a reliable indicator for tonometry, and the one on the air jet pressure predicts the outcomes of two or more distinct measurements on the same cornea, which can be used in inverse procedures to estimate the material properties of the tissue.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Corneal surgery and disorders · Glaucoma and retinal disorders · Corneal Surgery and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (41)
Show source-provided references
1. Biomechanical modeling of refractive corneal surgery10.1115/1.2132368 ↗
2. Evaluation of corneal shape and biomechanics before lasik10.1097/IIO.0b013e31820f1d2d ↗
3. Ariza-Gracia, M.A., Zurita, J.F., Piñero, D.P., Rodriques-Matas, J.F., Calvo, B., 2015. Coupled biomechanical response of the cornea assessed by non-contact tonometry. A simulation study. PLoS ONE 10 (3), e0121486.10.1371/journal.pone.0121486 ↗
4. Constitutive laws for biomechanical modeling of refractive surgery10.1115/1.2796033 ↗
5. Finite element analysis applied to cornea reshaping10.1117/1.2136149 ↗
6. Mechanisms of self-organization for the collagen fibril lattice in the human cornea10.1098/rsif.2013.0512 ↗
7. Finite element modeling of corneal biomechanical behavior10.3928/1081597X-20090710-01 ↗
8. Farandos, N.M., Yetisen, A.K., Monteiro, M.J., Lowe, C.R., Yun, S.H., 2015. Contact lens sensors in ocular diagnostics. Advanced Healthcare Materials 4 (6),792–810, 〈10.1002/adhm.201400504〉.10.1002/adhm.201400504 ↗
9. Accuracy of Goldmann tonometry after refractive surgery10.1016/S0886-3350(97)80239-8 ↗
10. Intraocular pressure change measured by Goldmann tonometry after laser in situ keratomileusis10.1016/S0886-3350(98)80041-2 ↗
11. A viscoelastic biomechanical model of the cornea describing the effect of viscosity and elasticity on hysteresis10.1167/iovs.07-1321 ↗
12. Uber applanations—tonometrie10.1159/000303213 ↗
13. Air puff induced corneal vibrations: theoretical simulations and clinical observations10.3928/1081597X-20140212-02 ↗
14. Corneal deformation measurement using Scheimpflug noncontact tonometry10.1097/OPX.0b013e318279eb87 ↗
15. A new tonometer—the Corvis ST tonometer: clinical comparison with noncontact and Goldmann applanation tonometers10.1167/iovs.12-10984 ↗
16. Thermal and biomechanical parameters of porcine cornea10.1097/00003226-200005000-00020 ↗
17. Corneal viscoelastic properties from finite-element analysis of in vivo air-puff deformation10.1371/journal.pone.0104904 ↗
18. Corneal thickness- and age-related biomechanical properties of the cornea measured with the ocular response analyzer10.1167/iovs.06-0557 ↗
19. Corneal biomechanical properties and intraocular pressure changes after phacoemulsification and intraocular lens implantation10.1016/j.jcrs.2008.08.017 ↗
20. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer10.1016/j.jcrs.2004.10.044 ↗
21. Association between corneal hysteresis and central corneal thickness in glaucomatous and non-glaucomatous eyes10.1111/j.1755-3768.2008.01370.x ↗
22. Ocular Response Analyzer versus Goldmann applanation tonometry for intraocular pressure measurements10.1167/iovs.06-0158 ↗
23. The use of X-ray scattering techniques to quantify the orientation and distribution of collagen in the corneal stroma10.1016/j.preteyeres.2009.06.005 ↗
24. Reproducibility and clinical relevance of the ocular response analyzer in nonoperated eyes: cornea biomechanical and tonometric implications10.1167/iovs.07-0280 ↗
25. A method of computation for structural dynamics10.1061/JMCEA3.0000098 ↗
26. Circumcorneal annulus of collagen fibrils in the human limbus
27. Finite element simulations of laser refractive corneal surgery10.1007/s00366-008-0102-5 ↗
28. Three-dimensional modelling and computational analysis of the human cornea considering distributed collagen fiber orientation10.1115/1.2982251 ↗
29. A material model for the human cornea. Constitutive behavior and numerical analysis10.1007/s10237-005-0014-x ↗
30. Fiber distributed hyperelastic modeling of biological tissues10.1016/j.mechmat.2011.06.004 ↗
31. In vivo characterization of corneal biomechanics10.1016/j.jcrs.2014.03.021 ↗
32. Three-dimensional modeling of metabolic species transport in the cornea with a hydrogel intrastromal inlay10.1167/iovs.13-13844 ↗
33. Computational modeling of mechanical anisotropy in the cornea and sclera10.1016/j.jcrs.2004.10.048 ↗
34. Concepts and misconceptions in corneal biomechanics10.1016/j.jcrs.2014.04.019 ↗
35. Air-puff associated quantification of non-linear biomechanical properties of the human cornea in vivo10.1016/j.jmbbm.2015.04.010 ↗
36. Biomechanical and optical behavior of human corneas before and after photorefractive keratectomy10.1016/j.jcrs.2014.03.020 ↗
37. Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes10.1167/iovs.04-0694 ↗
38. Simonini, I., Angelillo, M., Pandolfi, A. Theoretical and numerical analysis of the corneal air puff tests. J. Mech. Phys. Solid 1–14, under review.
39. Customized finite element modelling of the human cornea10.1371/journal.pone.0130426 ↗
40. Patient-specific modeling of corneal refractive surgery outcomes and inverse estimation of elastic property changes10.1115/1.4002934 ↗
41. Correlations between corneal hysteresis, intraocular pressure, and corneal central pachymetry10.1016/j.jcrs.2007.11.051 ↗