PVA matches human liver in needle-tissue interaction
Source abstract
Abstract
Medical phantoms can be used to study needle-tissue interaction and to train medical residents. The purpose of this research is to study the suitability of polyvinyl alcohol (PVA) as a liver tissue mimicking material in terms of needle-tissue interaction. Insertions into ex-vivo human livers were used for reference. Six PVA samples were created by varying the mass percentage of PVA to water (4m% and 7m%) and the number of freeze-thaw cycles (1, 2 and 3 cycles, 16hours of freezing at -19°C, 8hours of thawing). The inner needle of an 18 Gauge trocar needle with triangular tip was inserted 13 times into each of the samples, using an insertion velocity of 5 mm/s. In addition, 39 insertions were performed in two ex-vivo human livers. Axial forces on the needle were captured during insertion and retraction and characterized by friction along the needle shaft, peak forces, and number of peak forces per unit length. The concentration of PVA and the number of freeze-thaw cycles both influenced the mechanical interaction between needle and specimen. Insertions into 4m% PVA phantoms with 2 freeze-thaw cycles were comparable to human liver in terms of estimated friction along the needle shaft and the number of peak forces. Therefore, these phantoms are considered to be suitable liver mimicking materials for image-guided needle interventions. The mechanical properties of PVA hydrogels can be influenced in a controlled manner by varying the concentration of PVA and the number of freeze-thaw cycles, to mimic liver tissue characteristics.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Cellular Mechanics and Interactions · 3D Printing in Biomedical Research · Soft Robotics and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (21)
Show source-provided references
1. Endpoint accuracy in manual control of a steerable needle
2. Polyacrylamide phantom for self-actuating needle–tissue interaction studies10.1016/j.medengphy.2013.07.004 ↗
3. Algorithms for the reduction of the number of points required to represent a digitized line or its caricature
4. Measurement and stochastic modeling of kidney puncture forces10.1007/s10439-013-0924-1 ↗
5. Needle–tissue interaction forces – A survey of experimental data10.1016/j.medengphy.2012.04.007 ↗
6. Forcing form and function: biomechanical regulation of tumor evolution10.1016/j.tcb.2010.08.015 ↗
7. Evaluation of a turkey-breast phantom for teaching freehand, US-guided core-needle breast biopsy10.1016/S1076-6332(97)80206-1 ↗
8. Hing, J.T., Brooks, A.D., Desai, J.P. 2006. Reality-based needle insertion simulation for haptic feedback in prostate brachytherapy. In: Proceedings of the 2006 IEEE International Conference on Robotics and Automation. ICRA 2006, pp. 619–624. 〈http://dx.doi.org/10.1109/ROBOT.2006.1641779〉.10.1109/ROBOT.2006.1641779 ↗
9. A review of the benefits and pitfalls of phantoms in ultrasound-guided regional anesthesia10.1097/AAP.0b013e31820d4207 ↗
10. PVA hydrogel properties for biomedical application10.1016/j.jmbbm.2011.04.005 ↗
11. de Jong, T.L., Dankelman, J., van den Dobbelsteen, J.J. 2016. Dataset of force measurements of needle insertions into two ex-vivo human livers, Data in Brief, “Submitted”.10.1016/j.dib.2017.01.018 ↗
12. Measurement of the tip and friction force acting on a needle during penetration
13. Development of a new hybrid gel phantom using carrageenan and gellan gum for visualizing three-dimensional temperature distribution during hyperthermia and radiofrequency ablation
14. Tissue-mimicking phantom materials for narrowband and ultrawideband microwave applications10.1088/0031-9155/50/18/001 ↗
15. Misra, S., Reed, K.B., Douglas, A.S., Ramesh, K.T., Okamura, A.M., 2008. Needle-tissue interaction forces for bevel-tip steerable needles. In: Proceedings of the IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics. pp. 224–231. 〈http://dx.doi.org/10.1109/BIOROB.2008.4762872〉.10.1109/BIOROB.2008.4762872 ↗
16. Okay · 2014
17. Tensional homeostasis and the malignant phenotype10.1016/j.ccr.2005.08.010 ↗
18. Podder, T.K., Sherman, J., Fuller, D., Messing, E.M., Rubens, D.J., Strang, J.G., Brasacchio, R.A., Yu, Y., 2006. In-vivo measurement of surgical needle intervention parameters: a pilot study.In: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference. 1, pp. 3652–3655. 〈http://dx.doi.org/10.1109/IEMBS.2006.259917〉.10.1109/IEMBS.2006.259917 ↗
19. Modeling of needle insertion forces for percutaneous therapies
20. Poly (vinyl alcohol) cryogel phantoms for use in ultrasound and MR imaging10.1088/0031-9155/49/24/009 ↗
21. Acoustical properties of selected tissue phantom materials for ultrasound imaging10.1088/0031-9155/52/20/N02 ↗