journal article·2019-06Open access

Fretting-corrosion behavior on dental implant connection in human saliva

Pascale Corne, Pascal De March, Franck Cleymand, Jean Geringer

Abstract

Fretting-corrosion has been pointed out as failure mechanism in dental implants between the implant part and the abutment. Depending on countries, surgical habits, 4 combinations of materials, are well used. The behavior of fretting corrosion of these four combinations of materials have been highlighted: pure titanium (Ti-grade 4) against titanium alloy (Ti-6Al-4V); titanium alloy (Ti-6Al-4V); against titanium alloy (Ti-6Al-4V); pure titanium against zirconia stabilized with Yttria (Y-TZP) and titanium alloy (Ti-6Al-4V) against zirconia (Y-TZP). Around 100 MPa of contact pressure, approx. the maximal mechanical stresses in dental assembly, after 16 h of fretting corrosion (± 40 µm, displacement) solicitations in Human saliva, the best assembly is Ti material (pure titanium-grade 4) against zirconia in terms of mechanical and electrochemical degradations. The electrochemical behavior has been investigated: the OCP, open circuit potential, is recovering its initial value even during fretting corrosion solicitations, Ti or Ti-6Al-4V against zirconia stabilized with Yttria (Y-TZP), outlier result but realistic. Some Tribological Transformed Structures on titanium material have been isolated as stir welding effect, STEM observations. Some transfer of zirconia through titanium material has been identified. Ti vs. Y-TZP clearly appears as the best performance couple under fretting corrosion conditions in human saliva. Lastly, some debris due to fretting corrosion have been isolated.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Mechanical stress and fatigue analysis · Titanium Alloys Microstructure and Properties · Hydrogen embrittlement and corrosion behaviors in metals

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (50)

Show source-provided references
1. Tribo-electrochemical behavior of bio-functionalized TiO2 nanotubes in artificial saliva: understanding of degradation mechanisms10.1016/j.wear.2017.05.005 ↗
2. Synergistic interactions between corrosion and wear at titanium-based dental implant connections: a scoping review10.1111/jre.12469 ↗
3. Load bearing capacity of tool pin during friction stir welding10.1007/s00170-011-3759-7 ↗
4. Effect of titania anodic formation and hydroxyapatite electrodeposition on electrochemical behaviour of Ti–6Al–4V alloy under fretting conditions for biomedical applications10.1016/j.corsci.2014.11.026 ↗
5. Osseointegration and its experimental background10.1016/S0022-3913(83)80101-2 ↗
6. Subsurface microstructure of metal-on-metal hip joints and its relationship to wear particle generation10.1002/jbm.b.30132 ↗
7. Cardarelli · 2008
8. Tribo-corrosion of materials: interplay between chemical, electrochemical, and mechanical reactivity of surfaces10.1016/j.wear.2006.03.027 ↗
9. An overview of the corrosion aspect of dental implants (titanium and its alloys)10.4103/0970-9290.49068 ↗
10. Is there scientific evidence favoring the substitution of commercially pure titanium with titanium alloys for the manufacture of dental implants?10.1016/j.msec.2016.10.025 ↗
11. Fixed partial prostheses supported by 2 or 3 implants: a retrospective study up to 18 years
12. Tool wear characteristics and effect on microstructure in Ti-6Al-4V friction stir welded joints
13. An energy description of hard coating wear mechanisms10.1016/S0257-8972(00)01161-0 ↗
14. Analysis of sliding behaviour for fretting loadings: determination of transition criteria10.1016/0043-1648(94)06582-9 ↗
15. Quantification of fretting damage10.1016/S0043-1648(96)07306-1 ↗
16. Wear analysis in fretting of hard coatings through a dissipated energy concept10.1016/S0043-1648(96)07436-4 ↗
17. An energy description of wear mechanisms and its applications to oscillating sliding contacts10.1016/S0043-1648(03)00117-0 ↗
18. Application of an energy wear approach to quantify fretting contact durability: introduction of a wear energy capacity concept10.1016/j.triboint.2007.02.011 ↗
19. Tribocorrosion behavior of plasma nitrided Ti–6Al–4V alloy in neutral NaCl solution10.1016/S0257-8972(01)01309-3 ↗
20. Fretting corrosion processes and wear mechanisms in medical implants
21. Friction/fretting-corrosion mechanisms: current trends and outlooks for implants10.1016/j.matlet.2014.06.167 ↗
22. Micromotion and dynamic fatigue properties of the dental implant–abutment interface10.1067/mpr.2001.112796 ↗
23. Analysis of energy dissipation in fretting corrosion experiments with materials used as hip prosthesis10.1016/j.wear.2012.07.014 ↗
24. Comparative corrosion study of Ti-Ta alloys for dental applications10.1016/j.actbio.2009.05.037 ↗
25. What is the role of lipopolysaccharide on the tribocorrosive behavior of titanium?10.1016/j.jmbbm.2011.11.004 ↗
26. Tribocorrosion and oral and maxillofacial surgical devices10.1016/j.bjoms.2014.02.010 ↗
27. Triboelectrochemical techniques and interpretation methods in tribocorrosion: a comparative evaluation10.1016/j.triboint.2007.11.003 ↗
28. Tribocorrosion
29. A round robin on combined electrochemical and friction tests on alumina/stainless steel contacts in sulphuric acid10.1016/S0043-1648(00)00559-7 ↗
30. Effect of corrosion on the wear behavior of passivating metals in aqueous solutions
31. Effect of sulphuric acid concentration on the rate of tribocorrosion of iron10.1016/0043-1648(93)90314-C ↗
32. Variability of human saliva composition: possible relationships with fat perception and liking10.1016/j.archoralbio.2011.09.016 ↗
33. Cluster of bacteria associated with peri-implantitis10.1111/cid.12052 ↗
34. Fretting corrosion between 316LSS and PMMA: influence of ionic strength, protein and electrochemical conditions on material wear. Application to orthopedic implants10.1016/j.wear.2011.01.082 ↗
35. Electrochemical techniques for studying tribocorrosion processes10.1016/S0043-1648(03)00556-8 ↗
36. Subsurface changes of a MoM hip implant below different contact zones10.1016/j.jmbbm.2008.08.002 ↗
37. Characterization of wear particles generated from CoCrMo alloy under sliding wear conditions10.1016/j.wear.2010.12.045 ↗
38. Inter-individual variability of protein patterns in saliva of healthy adults10.1016/j.jprot.2009.05.004 ↗
39. Dynamic surface microstructural changes during tribological contact that determine the wear behaviour of hip prostheses: metals and ceramics10.1039/c2fd00002d ↗
40. Biomechanical influence of crown-to-implant ratio on stress distribution over internal hexagon short implant: 3-D finite element analysis with statistical test10.1016/j.jbiomech.2014.10.021 ↗
41. Degradation mechanisms and future challenges of titanium and its alloys for dental implant applications in oral environment10.1016/j.msec.2017.02.159 ↗
42. Titanium corrosion mechanisms in the oral environment: a retrieval study10.3390/ma6115258 ↗
43. Systematic review of the survival rate and the biological, technical, and aesthetic complications of fixed dental prostheses with cantilevers on implants reported in longitudinal studies with a mean of 5 years follow-up
44. On the mechanical integrity of retrieved dental implants10.1016/j.jmbbm.2015.05.014 ↗
45. Titanium release from implants: a proposed mechanism
46. Simultaneous degradation by corrosion and wear of titanium in artificial saliva containing fluorides10.1016/j.wear.2012.05.030 ↗
47. In vitro evaluation of the effects of multiple oral factors on dental implants surfaces10.1563/aaid-joi-D-15-00165 ↗
48. Corrosion of surgical implants in vivo and in vitro tests
49. Influence of pH and corrosion inhibitors on the tribocorrosion of titanium in artificial saliva10.1016/j.wear.2006.03.031 ↗
50. Wear mechanisms in metal-on-metal bearings: the importance of tribochemical reaction layers