journal article·2014-11

Wear and friction properties of experimental Ti–Si–Zr alloys for biomedical applications

Serhii Tkachenko, Oleg Datskevich, Leonid Kulak, Staffan Jacobson, Håkan Engqvist, Cecilia Persson

Publisher page

Abstract

Titanium alloys are widely used in biomedical applications due to their higher biocompatibility in comparison to other metallic biomaterials. However, they commonly contain aluminum and vanadium, whose ions may be detrimental to the nervous system. Furthermore, they suffer from poor wear resistance, which limits their applications. The aim of this study was to evaluate the tribological performance of experimental Ti-1.25Si-5Zr, Ti-2.5Si-5Zr, Ti-6Si-5Zr and Ti-2.5Si-5Zr-0.2Pd alloys as compared to that of control Ti-6Al-4V, CoCr F75 and CoCr F799 alloys. Friction and wear tests were performed using a standard ball-on-disc rig in serum solution at ambient temperature with Si3N4-balls as counterparts. The alloys microstructure and hardness were investigated using optical microscopy, XRD, scanning electron microscopy (SEM) and Vickers indentation. The coefficients of friction of the experimental Ti-Si-Zr alloys were generally lower than the commercial ones with Ti-6Si-5Zr presenting the lowest value (approx. 0.1). Their wear rates were found to be 2-7 times lower than that of the commercial Ti-6Al-4V alloy, but still higher than those of the CoCr alloys. SEM analysis of worn surfaces showed that abrasion was the predominant wear mechanism for all studied materials. Wear and friction were influenced by the formation and stability of transfer layers, and while commercial Ti-6Al-4V as well as the experimental Ti-Si-Zr alloys demonstrated extensive material transfer to the ceramic counterparts, the CoCr alloys did not show such material transfer.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty · Advanced materials and composites

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (43)

Show source-provided references
1. Tribology and total hip joint replacement: Current concepts in mechanical simulation10.1016/j.medengphy.2008.07.006 ↗
2. Surface modification of Ti–6Al–4V alloy using laser-assisted deposition of a Ti–Si compound10.1016/j.surfcoat.2008.06.160 ↗
3. ASTM · 2011
4. Microstructure, mechanical and wear properties of laser surface melted Ti6Al4V alloy
5. Investigation of influence of alloying elements on phase and structural transformations under quenching in alloys on the base of Ti–Si system
6. Effect of palladium on the corrosion behavior of titanium10.1016/j.corsci.2003.10.003 ↗
7. Tribological properties of titanium alloys10.1016/0043-1648(91)90249-T ↗
8. The melting diagram of the Ti-corner of the Ti–Zr–Si system and mechanical properties of as-cast compositions10.1016/j.jallcom.2004.02.060 ↗
9. Characterization and wear behavior of modified silicon nitride10.1016/j.ijrmhm.2005.06.004 ↗
10. Wear and corrosion behaviour of Ti–13Nb–13Zr and Ti–6Al–4V alloys in simulated physiological solution10.1016/j.corsci.2010.11.014 ↗
11. International multilaboratory sliding wear tests with ceramics and steel10.1016/0043-1648(89)90104-X ↗
12. Martensitic transformations in Ti–Mo alloys10.1007/BF00772735 ↗
13. Disegi · 1999
14. Tribological behaviour of alumina sliding against Ti6Al4V in unlubricated contact10.1016/S0043-1648(98)00407-4 ↗
15. Enhanced wear resistance of titanium surfaces by a new thermal oxidation treatment10.1016/S0043-1648(99)00359-2 ↗
16. Environmental effect on fretting of metallic materials for orthopaedic implants10.1016/S0043-1648(03)00522-2 ↗
17. Biocompatibility of beta-stabilizing elements of titanium alloys
18. Titanium “irons” and titanium “steels”10.1007/s11041-009-9119-7 ↗
19. The effect of Si, Zr, Al and Mo on the structure and strength of Ti martensite10.1007/BF00550440 ↗
20. Ti based biomaterials, the ultimate choice for orthopaedic implants – a review10.1016/j.pmatsci.2008.06.004 ↗
21. Friction and wear of Al2O3, ZrO2 and SiO2 rubbed against pure metals10.1016/0043-1648(92)90176-9 ↗
22. Structure and properties of cast binary Ti–Mo alloys10.1016/S0142-9612(99)00114-3 ↗
23. Pin-on-disk wear behavior in a like-on-like configuration in a biological environment of high carbon cast and low carbon forged Co–29Cr–6Mo alloys10.1016/j.actamat.2006.10.005 ↗
24. Johnson · 1985
25. Friction and wear behavior of titanium matrix (TiB+TiC) composites10.1016/j.wear.2010.12.072 ↗
26. Vanadium exposure-induced neurobehavioral alterations among Chinese workers
27. Mechanical and biotribological properties of ceramic–metal composites (TiC/Ti–15Mo and SiC/Ti–15Mo) for joint prostheses and the effects of additive metallic elements of W, Nb, and Ir10.1016/j.msea.2012.03.113 ↗
28. Adhesion and friction of transition metals in contact with non-metallic hard materials10.1016/0043-1648(82)90109-0 ↗
29. Recent metallic materials for biomedical applications10.1007/s11661-002-0109-2 ↗
30. Evaluation of silicon nitride as a wear resistant and resorbable alternative for total hip joint replacement10.4161/biom.20710 ↗
31. Friction and wear of titanium alloys sliding against metal, polymer, and ceramic counterfaces10.1016/j.wear.2004.09.062 ↗
32. In vitro human monocyte response to wear particles of titanium alloy containing vanadium or niobium10.1302/0301-620X.79B2.0790311 ↗
33. Samsonov · 1979
34. Aluminum in the central nervous system (CNS): toxicity in humans and animals, vaccine adjuvants, and autoimmunity10.1007/s12026-013-8403-1 ↗
35. The influence of surface roughness on friction and wear of machine element coatings10.1016/S0043-1648(03)00341-7 ↗
36. Tribological behaviour of alumina sliding on several kinds of materials10.1016/0043-1648(93)90249-L ↗
37. Research and development of metals for medical devices based on clinical needs10.1088/1468-6996/13/6/064102 ↗
38. Investigation of tribological properties of Ti–Si alloys after end quenching
39. Special modes of corrosion under physiological and simulated physiological conditions10.1016/j.actbio.2007.12.003 ↗
40. Effect of operational variables, microstructure and mechanical properties on the erosion of Ti–6Al–4V10.1016/0043-1648(91)90168-T ↗
41. Wear and corrosion behaviour of various surface treated medical grade titanium alloy in bio-simulated environment10.1016/j.wear.2009.01.056 ↗
42. Microstructure and tribological behavior of Ti–Si eutectic alloys with Al addition10.1007/s11249-006-9178-5 ↗
43. Composition and lattice parameters of silicide and matrix in cast Ti–Si–Al–Zr alloys10.1179/mst.1991.7.9.812 ↗