journal article·2019-09Open access

Quantification of human bone microarchitecture damage in press-fit femoral knee implantation using HR-pQCT and digital volume correlation

Sophie Rapagna, Sanaz Berahmani, Caroline E. Wyers, Joop P.W. van den Bergh, Karen J. Reynolds, Gianluca Tozzi, Dennis Janssen, Egon Perilli

Abstract

Primary press-fit fixation of femoral knee prostheses is obtained thanks to the inside dimensions of the implant being undersized with respect to the bone cuts created intra-operatively, dictated by a press-fit specified by the implant design. However, during prostheses press-fit implantation, high compressive and shear stresses at the implant-bone interface are generated, which causes permanent bone damage. The extent of this damage is unknown, but it may influence the implant stability and be a contributing factor to aseptic loosening, a main cause of revisions for knee arthroplasty. The aim of this ex-vivo study was to quantify, using high-resolution peripheral quantitative computed tomography (HR-pQCT) imaging and Digital Volume Correlation (DVC), permanent bone deformation due to press-fit femoral knee implantation of a commonly used implant. Six human cadaveric distal femora were resected and imaged with HR-pQCT (60.7 μm/voxel, isotropic). Femurs were fitted with cementless femoral knee implants (Sigma PFC) and rescanned after implant removal. For each femur, permanent deformation was examined in the anterior, posterior-medial and posterior-lateral condyles for volumes of interest (VOIs) of 10 mm depth. The bone volume fraction (BV/TV) for the VOIs in pre- and post-implantation images was calculated, at increasing depth from the bone surface. DVC was applied on the VOIs pre- and post-implantation, to assess trabecular bone displacements and plastically accumulated strains. The "BV/TVpost/BV/TVpre ratio vs. depth" showed, consistently among the six femurs, three consecutive points of interest at increasing bone depth, indicating: bone removal (ratio<100%), compaction (ratio>100%) and no changes (ratio = 100%). Accordingly, the trabecular bone displacement computed by DVC suggested bone compaction up to 2.6 ± 0.8 mm in depth, with peak third principal strains of -162,100 ± 55,000 με (mean absolute error: 1,000-2,000 με, SD: 200-500 με), well above the yield strain of bone (7,000-10,000 με). Combining 3D-imaging, at spatial resolutions obtainable with clinical HR-pQCT, and DVC, determines the extent of plastic deformation and accumulated compressive strains occurring within the bone due to femoral press-fit implantation. The methods and data presented can be used to compare different implants, implant surface coatings and press-fit values. These can also be used to advance and validate computational models by providing information about the bone-implant interface obtained experimentally. Future studies using these methods can assist in determining the influence of bone damage on implant stability and the subsequent osseointegration.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Orthopedic Infections and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (38)

Show source-provided references
1. Current methods of preventing aseptic loosening and improving osseointegration of titanium implants in cementless total hip arthroplasty: a review10.1177/0300060517732697 ↗
2. Towards validation of computational analyses of peri-implant displacements by means of experimentally obtained displacement maps10.1080/10255842.2010.537263 ↗
3. Digital volume correlation: three-dimensional strain mapping using X-ray tomography10.1007/BF02323555 ↗
4. Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue10.1016/S0021-9290(03)00257-4 ↗
5. Evaluation of interference fit and bone damage of an uncemented femoral knee implant10.1016/j.clinbiomech.2017.10.022 ↗
6. The influence of bone damage on press-fit mechanics10.1016/j.jbiomech.2014.01.029 ↗
7. The role of bone debris in early healing adjacent to hydrophilic and hydrophobic implant surfaces in man10.1111/j.1600-0501.2010.02107.x ↗
8. The initial stability of uncemented acetabular components10.1302/0301-620X.74B3.1587880 ↗
9. Influence of trabecular bone quality and implantation direction on press-fit mechanics10.1002/jor.23257 ↗
10. Biomechanics and strain mapping in bone as related to immediately-loaded dental implants10.1016/j.jbiomech.2015.05.014 ↗
11. The application of digital volume correlation (DVC) to study the microstructural behaviour of trabecular bone during compression10.1016/j.jmbbm.2013.09.014 ↗
12. Graves · 2018
13. The effect of bone compaction on early fixation of porous-coated implants10.1016/S0883-5403(99)90208-5 ↗
14. The technique of cementless total knee replacement10.1097/00013611-199112000-00003 ↗
15. Digital volume correlation for study of the mechanics of whole bones10.1016/j.piutam.2012.05.013 ↗
16. Surface modifications and their effects on titanium dental implants10.1155/2015/791725 ↗
17. Implant fixation by bone ingrowth10.1016/S0883-5403(99)90063-3 ↗
18. Bone compaction enhances fixation of weightbearing titanium implants10.1097/01.blo.0000150461.69142.f3 ↗
19. Quantitative in vivo assessment of bone microarchitecture in the human knee using HR-pQCT10.1016/j.bone.2016.12.015 ↗
20. Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular bone10.1016/j.jbiomech.2007.04.019 ↗
21. Time-elapsed synchrotron-light microstructural imaging of femoral neck fracture10.1016/j.jmbbm.2018.05.016 ↗
22. Dependence of yield strain of human trabecular bone on anatomic site10.1016/S0021-9290(01)00011-2 ↗
23. NJR Editorial Board · 2018
24. Three-Dimensional local measurements of bone strain and displacement: comparison of three digital volume correlation approaches10.1115/1.4030174 ↗
25. Structural parameters and mechanical strength of cancellous bone in the femoral head in osteoarthritis do not depend on age10.1016/j.bone.2007.07.014 ↗
26. MicroCT examination of human bone specimens: effects of polymethylmethacrylate embedding on structural parameters10.1111/j.1365-2818.2007.01731.x ↗
27. Micro-CT examination of human bone: from biopsies towards the entire organ
28. Observations on the effect of movement on bone ingrowth into porous-surfaced implants10.1097/00003086-198607000-00023 ↗
29. Press · 1992
30. Application of the digital volume correlation technique for the measurement of displacement and strain fields in bone: a literature review10.1016/j.jbiomech.2014.01.001 ↗
31. Systematic mapping of the subchondral bone 3D microarchitecture in the human tibial plateau: variations with joint alignment10.1002/jor.23474 ↗
32. Robertsson · 2017
33. Digital volume correlation and micro-CT: an in-vitro technique for measuring full-field interface micromotion around polyethylene implants10.1016/j.jbiomech.2015.05.024 ↗
34. The influence of surface roughness on the displacement of osteogenic bone particles during placement of titanium screw-type implants10.1111/j.1708-8208.2009.00216.x ↗
35. Finite element analysis of the implanted proximal tibia: a relationship between the initial cancellous bone stresses and implant migration10.1016/S0021-9290(98)00022-0 ↗
36. Elastic full‐field strain analysis and microdamage progression in the vertebral body from digital volume correlation10.1111/str.12202 ↗
37. Strain uncertainties from two digital volume correlation approaches in prophylactically augmented vertebrae: local analysis on bone and cement-bone microstructures10.1016/j.jmbbm.2016.12.006 ↗
38. Spatial resolution and measurement uncertainty of strains in bone and bone-cement interface using digital volume correlation10.1016/j.jmbbm.2015.12.017 ↗