journal article·2008-04

Bone material properties and fracture analysis: Needle insertion for spinal surgery

S.H. Teoh, C.K. Chui

Publisher page

Abstract

The effectiveness of percutaneous needle-based therapy and biopsy is demonstrated in a wide variety of medical problems including spinal disorders. Combined with osteoporosis, spinal disorders are increasingly prevalent as our society ages. However, the final position of the needle depends on a complex interplay of material properties of the bone and/or pathology, as well as the shape and material of the needle, and the insertion dynamics. This paper is a survey of the literature in the area of bone material properties and needle/bone interaction in the context of needle placement. It describes research findings on bone material properties and fractures using micro-CT imaging, and integrative imaging. This review paper also discusses the feasibility of using computational methods to predict fracture by simulating needle placement on any patient-specific model with both geometrical and mechanical properties approximating those of the patient's anatomy.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopedic Infections and Treatments · Bone and Joint Diseases · Infectious Diseases and Tuberculosis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (100+)

Show source-provided references
1. Ansys, 1999. Ansys, Theory Reference, release 5.6
2. A continuous wave technique for the measurement of the elastic properties of cortical bone10.1016/0021-9290(84)90029-0 ↗
3. Finite element stress analysis of an intervertebral disc10.1016/0021-9290(74)90019-0 ↗
4. Patient-specific finite element modeling of the human lumbar spine motion segment
5. Improved bone marrow biopsy technique10.1111/j.1600-0609.1991.tb01579.x ↗
6. Tactile VR for hand–eye coordination in simulated PTCA10.1016/j.compbiomed.2004.10.002 ↗
7. An improved method for finite element mesh generation of geometrically complex structures with application to the skullbase10.1016/S0021-9290(97)00073-0 ↗
8. Stress distribution in a physical buttock model: Effect of simulated bone geometry10.1016/0021-9290(92)90054-5 ↗
9. Bone compressive strength: The influence of density and strain rate10.1126/science.996549 ↗
10. The compressive behavior of bone as a two-phase porous structure10.2106/00004623-197759070-00021 ↗
11. Mechanical properties and composition of cortical bone10.1097/00003086-197809000-00041 ↗
12. Patient specific finite element model of the face soft tissues for computer-assisted maxillofacial surgery10.1016/S1361-8415(02)00108-1 ↗
13. Experimental techniques for bone mechanics
14. Training and pretreatment planning of interventional neuroradiology procedures–initial clinical validation
15. Haptics in computer-mediated simulation: Training in vertebroplasty surgery10.1177/1046878106291667 ↗
16. Integrative haptic and visual interaction for simulation of PMMA injection during vertebroplasty
17. Chui, C.K., Teoh, S.H., Ong, C.J., Anderson, J.H., Sakuma, I., 2006c. Integrative modeling of liver organ for simulation of flexible needle insertion. In: 9th International Conference on Control, Automation, Robotics and Vision, ICARCV 2006. Singapore10.1109/ICARCV.2006.345472 ↗
18. Methods for quantitative analysis of trabecular bone structure
19. Bone microarchitecture and mechanical resistance10.1016/S1297-319X(01)00283-4 ↗
20. Management of male osteoporosis10.1016/S1297-319X(01)00272-X ↗
21. Percutaneous vertebroplasty for osteolytic metastases and myeloma: Effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up10.1148/radiology.200.2.8685351 ↗
22. The mesh-matching algorithm: An automatic 3D mesh generator for finite element structures10.1016/S0021-9290(00)00055-5 ↗
23. Cowin · 2001
24. Functional adaptation in long bones: Establishing in vivo values for surface remodeling rate coefficients10.1016/0021-9290(85)90022-3 ↗
25. Properties of bone
26. Insertion of microneedles into skin: Measurement and prediction of insertion force and needle fracture force10.1016/j.jbiomech.2003.12.010 ↗
27. Percutaneous vertebroplasty with polymethylmethacrylate. Technique, indications, and results10.1016/S0033-8389(05)70042-7 ↗
28. Interactive simulation of needle insertion models10.1109/TBME.2005.847548 ↗
29. Experimental validation of poroelastic finite element predictions for the fluid pressure and solid stress in the annulus fibrosis
30. High-contrast resolution of CT images for bone structure analysis10.1118/1.596847 ↗
31. Fichtinger, G., Deguet, A., Masamune, K., Balogh, E., Fischer, G., Mathieu, H., Taylor, R.H., Fayad, L.M., Zinreich, S.J., 2004. Needle Insertion in CT Scanner with Image Overlay — Cadaver Studies. MICCAI 200410.1007/978-3-540-30136-3_97 ↗
32. Image overlay guidance for needle insertion in CT scanner10.1109/TBME.2005.851493 ↗
33. Magnitude of the problem
34. Bone stiffness predicts strength similarly for human vertebral cancellous bone in compression and for cortical bone in tension10.1016/S8756-3282(99)00246-X ↗
35. Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty
36. Advanced imaging of bone macro and micro structure10.1016/S8756-3282(99)00109-X ↗
37. The mechanical behaviour of cancellous bone10.1016/0021-9290(85)90287-8 ↗
38. Biomechanics of cellular solids10.1016/j.jbiomech.2004.09.027 ↗
39. Gibson · 1997
40. Gibson · 1988
41. A combined finite element and optimization investigation of lumbar spine mechanics with and without muscles10.1097/00007632-199318110-00019 ↗
42. Biomechanical testing of the spine. Load-controlled versus displacement-controlled analysis10.1097/00007632-199511000-00017 ↗
43. A prototype haptic lumbar puncture simulator
44. Guo · 2004
45. Mechanical properties of cortical and cancellous bone
46. Should percutaneous vertebroplasty be used to treat osteoporotic fractures? An update10.1016/S1297-319X(01)00265-2 ↗
47. Characterization of microstructural anisotropy in orthotropic materials using second rank tensor10.1007/BF00540446 ↗
48. Frictional insertion kinetics of bone biopsy needles10.1115/1.1407829 ↗
49. A homogenization sampling procedure for calculating trabecular bone effective stiffness and tissue level stress10.1016/0021-9290(94)90019-1 ↗
50. Hughs · 1987
51. Cancellous bone strength measurements with the osteopenetrometer10.1243/EMED_JOUR_1984_013_019_02 ↗
52. Compressive strength of tibial cancellous bone. Instron and osteopenetrometer measurements in an autopsy material10.3109/17453678308992915 ↗
53. A comparative study of automatic finite element mesh generation techniques in orthorpaedic biomechanics
54. Jacobs · 2001
55. Bone marrow biopsy with unaltered architecture: A new biopsy device
56. Johnson, P.R., Petrinic, N., Still, E., 2005. Element-splitting for simulation of fracture in 3d solid continua. In: VIII International Conference on Computational Efficiency, COMPLAS VIII, CIMNE Barcelona
57. Kataoka, H., Washio, T., Chinzei, K., Mizuhara, K., Simone, C., Okamura, A.M., 2002. Measurement of tip and friction force acting on a needle during penetration. In: Medical Image Computing and Assisted Intervention — MICCAI 2002: 5th International Conference. Tokyo, Japan10.1007/3-540-45786-0_27 ↗
58. Architecture and trabecular bone — toward an improved understanding of the biomechanical effects of age, sex and osteoporosis
59. Validation of an automated method of three-dimensional finite element modelling of bone10.1016/0141-5425(93)90066-8 ↗
60. Automated three-dimensional finite element modelling of bone: A new method10.1016/0141-5425(90)90022-F ↗
61. Effect of disc degeneration at one level on the adjacent level in axial mode10.1097/00007632-199103000-00013 ↗
62. Yield strain behavior of trabecular bone10.1016/S0021-9290(98)00057-8 ↗
63. The element-free Galerkin method for dynamic propagation of arbitrary 3-d cracks10.1002/(SICI)1097-0207(19990228)44:6<767::AID-NME524>3.0.CO;2-G ↗
64. Evaluation of a microcomputed tomography system to study trabecular bone structure10.1002/jor.1100080608 ↗
65. Registration for computer-integrated surgery: Methodology, state of the art
66. Computer-assisted spine surgery: A technique for accurate transpedicular screw fixation using CT data and a 3-D optical localizer10.1002/(SICI)1522-712X(1995)1:1<65::AID-IGS10>3.0.CO;2-7 ↗
67. Evaluation of trabecular microarchitecture. Prospects for predicting the risk of osteoporosis and fracture
68. Lei, Y., Chui, C.K., Ong, S.H., Wang, S.C., Teoh, S.H., Yan, C.H., 2006. Measuring material properties of bone using CT imaging. In: 2nd MRS S Conference on Advanced Materials. Singapore
69. Realistic simulation of surgical cutting of soft tissues in real time with force feedback
70. Improved virtual surgical cutting based on physical experiments
71. Percutaneous verteproplasty in benign and malignant disease10.1097/00013414-200112000-00005 ↗
72. Stiffness behaviour of trabecular bone specimens10.1016/0021-9290(87)90270-3 ↗
73. The effect of specimen geometry on the mechanical behaviour of trabecular bone specimens10.1016/0021-9290(92)90255-Y ↗
74. Mechanical properties of trabecular bone. Dependency on strain rate10.1016/0021-9290(91)90305-7 ↗
75. Marching cubes: A high resolution 3D surface construction algorithm10.1145/37402.37422 ↗
76. Do bending, twisting, and diurnal fluid changes in the disc affect the propensity to prolapse? A viscoelastic finite element model10.1097/00007632-199611150-00006 ↗
77. Multi-axis mechanical simulator for epidural needle insertion
78. Biomechanics of load-bearing of the intervertebral disc: An experimental and finite element model10.1016/S1350-4533(96)00056-2 ↗
79. Percutaneous vertebroplasty: A developing standard of care for vertebral compression fractures
80. Matsumiya, K., Momoi, Y., Kobayshi, E., Sugano, N., Yonenobu, K., Inada, H., Tsuji, T., Sakuma, I., 2003. Forces and torques during robotic needle insertion to human vertebra. CARS 200310.1007/978-3-540-39899-8_34 ↗
81. In vivo study of forces during needle insertions
82. Mccarthy · 2002
83. Static and fatigue failure properties of thoracic and lumbar vertebral bodies and their relation to regional density10.1016/0021-9290(94)00155-W ↗
84. The partition of unity finite element method basic theory and applications10.1016/S0045-7825(96)01087-0 ↗
85. A finite element method for crack growth without remeshing10.1002/(SICI)1097-0207(19990910)46:1<131::AID-NME726>3.0.CO;2-J ↗
86. Dependence of yield strain of human trabecular bone on anatomic site10.1016/S0021-9290(01)00011-2 ↗
87. Normal vertebral body size and compressive strength: Relations to age and to vertebral and iliac trabecular bone compressive strength10.1016/8756-3282(86)90019-0 ↗
88. Morphometric analysis of noninvasively assessed bone biopsies: Comparison of high-resolution computed tomography and histologic sections10.1016/8756-3282(95)00489-0 ↗
89. Magnetic resonance elastography by direct visualization of propagating acoustic strain waves10.1126/science.7569924 ↗
90. Time-lapsed microstructural imaging of bone failure behavior10.1016/S0021-9290(03)00254-9 ↗
91. Nealen, M.M., Keiser, R., Boxerman, E., Carlson, M., 2005. Physically Based Deformable Models in Computer Graphics. State of the Art Report, Eurographics10.1111/j.1467-8659.2006.01000.x ↗
92. Nicole, M.G., Douglas, R.P., D B, T., 2003. An anatomical voxel-based FE contact analysis formulation
93. Force modeling for needle insertion into soft tissue10.1109/TBME.2004.831542 ↗
94. Ong, J.S.K., Chui, C.K., Wang, Z., Zhang, J., Teo, J.C.M., Yan, C.H., Ong, S.H., TEO, C.L., Teoh, S.H., 2006. Biomechanical modeling of bone needle interaction for haptic rendering in needle insertion simulation. In: 9th International Conference on Control, Automation, Robotics and Vision, ICARCV 2006. Singapore10.1109/ICARCV.2006.345477 ↗
95. Development of the needle insertion robot for percutaneous vertebroplasty
96. Bone histomorphometry: Standardization of nomenclature, symbols, and units. Report of the ASBMR Histomorphometry Nomenclature Committee10.1002/jbmr.5650020617 ↗
97. Bone marrow sampling
98. Ranking the fracture toughness of thin mammalian soft tissues using the scissors cutting test10.1016/S0021-9290(96)00101-7 ↗
99. Estimation of distal radius failure load with micro-finite element analysis models based on three-dimensional peripheral quantitative computed tomography images10.1016/S8756-3282(02)00736-6 ↗
100. Image-based micro-finite-element modeling for improved distal radius strength diagnosis: Moving from bench to bedside10.1385/JCD:7:2:153 ↗