Fatigue endurance of Ti-6Al-4V alloy with electro-eroded surface for improved bone in-growth
Source abstract
Abstract
Ti-6Al-4V hour-glass shaped rotating beam specimens with duplex microstructure were processed by electric discharge machining (EDM). A comparatively high peak current of 29A was utilized in order to increase surface roughness for improved osteointegration. High cycle fatigue (HCF) tests were performed in rotating beam loading (R=-1) on these EDM specimens and results were compared with electrolytically polished specimens serving as reference. As expected, the HCF performance of EDM specimens was inferior to the electrolytically polished specimens. A detailed study of fatigue crack nucleation and microcrack growth was carried out on failed specimens by SEM. The poor HCF strength of EDM specimens is explained by early crack nucleation due to the high notch sensitivity of Ti-6Al-4V. In addition, process-induced residual tensile stresses and microstructural effects may also account for the drastic loss in HCF performance relative to the electropolished baseline.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced Machining and Optimization Techniques · Titanium Alloys Microstructure and Properties · Advanced machining processes and optimization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (24)
Show source-provided references
1. Phase transformations during cooling in α+β titanium alloys10.1016/S0921-5093(97)00802-2 ↗
2. Improvement in the morphology of Ti-based surfaces: a new process to increase in vitro human osteoblast response10.1016/S0142-9612(01)00271-X ↗
3. Comparative in vivo evaluation of porous and dense duplex titanium and hydroxyapatite coatings with high roughnesses in different implantation environments10.1002/jbm.a.31995 ↗
4. Plasma surface modification of biomaterials10.1016/S0927-796X(02)00004-9 ↗
5. Ti based biomaterials, the ultimate choice for orthopaedic implants—a review10.1016/j.pmatsci.2008.06.004 ↗
6. Physical and biological characterizations of a novel multiphase anodic spark deposition coating to enhance implant osseointegration10.1007/s10856-005-4732-5 ↗
7. Electrical discharge machining of titanium alloy10.1016/j.apsusc.2007.05.031 ↗
8. Biomaterials in total joint replacement10.1016/j.colsurfb.2003.12.002 ↗
9. Plasma spraying of functionally graded hydroxyapatite/Ti–6Al–4V coatings10.1016/S0257-8972(03)00238-X ↗
10. Surface modification by electrical discharge machining: a review10.1016/j.jmatprotec.2008.09.032 ↗
11. Study of surface integrity using small area EDM process with a copper-tungsten electrode10.1016/j.msea.2003.08.046 ↗
12. 2003
13. Applications of plasma coatings in artificial joints: an overview10.1016/j.vacuum.2003.12.160 ↗
14. Surface modification of titanium, titanium alloys and related materials for biomedical applications10.1016/j.mser.2004.11.001 ↗
15. Titanium alloys in total joint replacement—a materials science perspective10.1016/S0142-9612(97)00146-4 ↗
16. Lutjering · 2003
17. Mueller, J., Rack, H.J., Wagner, L., 2007. Effects of supra- and sub-transus heat treatments on fatigue performance of Ti–6Al–4V. In: Ti-2007 Science and Technology. The Japan Institute of Metals. pp. 383–386.
18. Influence of and microstructure on high cycle fatigue of Ti–6Al–4V: bimodal vs. lamellar structure10.1007/s11661-002-0160-z ↗
19. Fatigue characteristics of metallic biomaterials10.1016/j.ijfatigue.2006.09.021 ↗
20. Long crack growth behaviour of implant material Ti–5Al–2.5Fe in air and simulated body environment related to microstructure10.1016/S0142-1123(00)00058-X ↗
21. Effect of electrical-discharging on formation of nanoporous bicompatible layer on titanium10.1016/j.jallcom.2009.11.197 ↗
22. Titanium alloys for biomedical applications10.1016/j.msec.2005.08.032 ↗
23. The ternary systems: Cr–Al–C, V–Al–C, and Ti–Al–C and the behavior of H-phases (M2AlC)10.1016/0022-4596(80)90569-1 ↗
24. Characteristics of hydroxyapatita coated titanium porous coatings on Ti–6Al–4V substrates by plasma sprayed method10.1002/jbm.b.30750 ↗