journal article·2018-01

Characterization of thick titanium plasma spray coatings on PEEK materials used for medical implants and the influence on the mechanical properties

Danny Vogel, Henry Dempwolf, Axel Baumann, Rainer Bader

Publisher page

Abstract

Coating poly-ether-ether-ketone (PEEK) with rough and porous titanium plasma spray (TPS) coatings is a technique which is commonly used to enhance the osseointegrative properties of medical implants. However, the influence of the TPS coating on the PEEK mechanical properties has not been sufficiently evaluated to date. In this study, PEEK samples were coated with a thick TPS layer with grains of 90µm and 180µm diameter. The coating characteristics and the adhesive strength of the coatings on the samples were determined and compared to coatings on titanium samples. The influence of the coating process on the mechanical and chemical-physical properties of PEEK was also evaluated. All TPS coatings on PEEK and titanium fulfilled the manufacturer's requirements for thickness (200 ± 50µm), porosity (30 ± 10%) and roughness (90µm grain diameter coating: 25 ± 5µm and 180µm grain diameter coating: 45 ± 15µm) and were able to meet the demands required for adhesive strength (> 22MPa) and shear strength (> 20MPa). However, the mechanical properties i.e. yield stress, fracture strain, flexural modulus and flexural stress, of the PEEK samples were influenced by the coating process, while the chemical-physical properties were not altered.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (68)

Show source-provided references
1. Aesculap AG, 2013. Mechanical Testing Summary. Adhesion Strength of the Plasmapore Coating to PEEK, Melsungen.
2. Biomaterials and interface with bone10.1007/s00198-011-1618-x ↗
3. The effect of stem stiffness on femoral bone resorption after canine porous-coated total hip arthroplasty10.1097/00003086-199012000-00022 ↗
4. Physical characterization of different-roughness titanium surfaces, with and without hydroxyapatite coating, and their effect on human osteoblast-like cells10.1002/jbm.b.30313 ↗
5. Comparative in vitro study on a ultra-high roughness and dense titanium coating10.1016/j.biomaterials.2005.01.010 ↗
6. The Lumbar I/F Cage for posterior lumbar interbody fusion with the variable screw placement system: 10-year results of a Food and Drug Administration clinical trial10.1016/j.spinee.2004.05.253 ↗
7. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs10.1002/jbm.820250708 ↗
8. A constitutive model of polyether-ether-ketone (PEEK)10.1016/j.jmbbm.2015.08.037 ↗
9. Mechanical properties of hydroxyapatite whisker reinforced polyetherketoneketone composite scaffolds10.1016/j.jmbbm.2009.07.002 ↗
10. Characterization of a peek composite segmental bone replacement implant10.1023/A:1004562732460 ↗
11. D20 Committee · 2012
12. Deutsches Institut fuer Normung e.V. · 1994
13. Deutsches Institut fuer Normung e.V. · 1998
14. Deutsches Institut fuer Normung e.V. · 1998
15. Deutsches Institut fuer Normung e.V. · 2012
16. Deutsches Institut fuer Normung e.V. · 2012
17. Deutsches Institut fuer Normung e.V. · 2013
18. Coating of carbon fiber-reinforced polyetheretherketone implants with titanium to improve bone apposition10.1002/jbm.b.32861 ↗
19. The influence of acetabular cup material on pelvis cortex surface strains, measured using digital image correlation10.1016/j.jbiomech.2011.11.042 ↗
20. Mechanical characterization and numerical simulation of polyether-ether-ketone (PEEK) cranial implants10.1016/j.jmbbm.2011.05.039 ↗
21. Impact of surface porosity and topography on the mechanical behavior of high strength biomedical polymers10.1016/j.jmbbm.2016.02.033 ↗
22. F04 Committee · 2005
23. F04 Committee · 2011
24. F04 Committee · 2014
25. F04 Committee · 2015
26. On the mechanical behaviour of PEEK and HA cranial implants under impact loading10.1016/j.jmbbm.2017.01.012 ↗
27. Cold gas spray titanium coatings onto a biocompatible polymer10.1016/j.matlet.2013.04.115 ↗
28. Outcomes evaluation of zero-profile devices compared to stand-alone PEEK cages for the treatment of three- and four-level cervical disc disease
29. Bone remodelling around cementless composite acetabular components: the effects of implant geometry and implant-bone interfacial conditions10.1016/j.jmbbm.2014.01.010 ↗
30. Osteointegrative surfaces for CF/PEEK implants
31. Plasma-sprayed hydroxylapatite coating on carbon fibre reinforced thermoplastic composite materials
32. The improvement of adhesive properties of PEEK through different pre-treatments10.1016/j.apsusc.2012.04.040 ↗
33. The strain-rate and temperature dependence of the mechanical properties of polyetherketone and polyetheretherketone10.1007/BF00357847 ↗
34. The electron beam deposition of titanium on polyetheretherketone (PEEK) and the resulting enhanced biological properties10.1016/j.biomaterials.2009.12.030 ↗
35. International Organization for Standardization · 2014
36. A study of the effect of forming temperature on the mechanical behaviour of carbon-fibre/peek composites10.1016/0266-3538(93)90076-S ↗
37. Porosity of 3D biomaterial scaffolds and osteogenesis10.1016/j.biomaterials.2005.02.002 ↗
38. Does surface roughness influence the primary stability of acetabular cups? A numerical and experimental biomechanical evaluation10.1016/j.medengphy.2014.07.003 ↗
39. Biological strategies for improved osseointegration and osteoinduction of porous metal orthopedic implants10.1089/ten.teb.2014.0333 ↗
40. Press-fit stability of uncemented hemispheric acetabular components: a comparison of three porous coating systems10.1007/s00264-001-0314-4 ↗
41. Interface interactions of osteoblasts with structured titanium and the correlation between physicochemical characteristics and cell biological parameters10.1002/mabi.200600293 ↗
42. Fatigue behavior of some filled polymers10.1177/002199837500900205 ↗
43. Observations on the effect of movement on bone ingrowth into porous-surfaced implants10.1097/00003086-198607000-00023 ↗
44. The mechanical properties of poly(ether-ether-ketone) (PEEK) with emphasis on the large compressive strain response10.1016/j.polymer.2006.11.032 ↗
45. Laser surface modification of PEEK10.1016/j.apsusc.2012.01.154 ↗
46. Effect of surface roughness, porosity, and a resorbable calcium phosphate coating on osseointegration of titanium in a minipig model10.1002/jbm.a.32000 ↗
47. PEEK dental implants: a review of the literature10.1563/AAID-JOI-D-11-00002 ↗
48. Flexural behavior of PEEK materials for dental application10.1016/j.dental.2015.08.151 ↗
49. The applicability of PEEK-based abutment screws10.1016/j.jmbbm.2016.06.024 ↗
50. Pressure behavior of different PEEK materials for dental implants10.1016/j.jmbbm.2015.10.003 ↗
51. Fatigue limits of different PEEK materials for dental implants10.1016/j.jmbbm.2016.12.019 ↗
52. Composite technology for total hip arthroplasty10.1097/00003086-198810000-00022 ↗
53. Notch sensitivity of PEEK in monotonic tension10.1016/j.biomaterials.2009.08.020 ↗
54. Carbon fiber reinforced PEEK Optima--a composite material biomechanical properties and wear/debris characteristics of CF-PEEK composites for orthopedic trauma implants10.1016/j.jmbbm.2012.09.013 ↗
55. Determinants of stress shielding: design versus materials versus interface10.1097/00003086-199201000-00020 ↗
56. Morphometric and mechanical evaluation of titanium implant integration: comparison of five surface structures10.1002/(SICI)1097-4636(200007)51:1<15::AID-JBM3>3.0.CO;2-9 ↗
57. The notch sensitivity of polymeric materials10.1002/app.1976.070200814 ↗
58. Fatigue of biomaterials: a review10.1016/S0142-1123(00)00052-9 ↗
59. Polyetheretherketone as a biomaterial for spinal applications10.1016/j.biomaterials.2005.07.011 ↗
60. Plasma-sprayed titanium coating to polyetheretherketone improves the bone-implant interface10.1016/j.spinee.2014.12.018 ↗
61. Carbon fiber reinforced polyether ether ketone composite as a bearing surface for total hip replacement10.1016/S0301-679X(98)00088-7 ↗
62. Suitability and limitations of carbon fiber reinforced PEEK composites as bearing surfaces for total joint replacements10.1016/S0043-1648(99)00026-5 ↗
63. Biotribological study of large diameter ceramic-on-CFR-PEEK hip joint including fluid uptake, wear and frictional heating10.1007/s10856-012-4617-3 ↗
64. Potential of polyetheretherketone (PEEK) and carbon-fibre-reinforced PEEK in medical applications10.1007/BF01728981 ↗
65. Bone density adjacent to press-fit acetabular components. A prospective analysis with quantitative computed tomography10.2106/00004623-200104000-00007 ↗
66. Influence of layer thickness and raster angle on the mechanical properties of 3D-printed PEEK and a comparative mechanical study between PEEK and ABS10.3390/ma8095271 ↗
67. Effect of thermal history on crystallization behavior of polyetheretherketone studied by differential scanning calorimetry10.1002/apmc.1988.051640102 ↗
68. Influence of the processing temperature on the tribological and mechanical properties of poly-ether-ether-ketone (PEEK) polymer10.1016/j.triboint.2015.08.016 ↗