journal article·2021-07

Effect of macrogeometry and bone type on insertion torque, primary stability, surface topography damage and titanium release of dental implants during surgical insertion into artificial bone

Gabrielle Alencar Ferreira Silva, Fernanda Faot, Anna Paula da Rosa Possebon, Wander José da Silva, Altair Antoninha Del Bel Cury

Publisher page

Abstract

This study investigated the influence of implant macrogeometry and bone type on insertion torque (IT), primary stability (ISQ), surface topography damage, and the amount of titanium (Ti) released during insertion. Forty implants with different macrogeometries (Facility - Cylindrical with spiral-shaped threads; Alvim - Tapered with buttress-shaped threads) were inserted into artificial bone types I-II and III-IV. Surface morphology was evaluated by Scanning Electron Microscope (SEM) and roughness parameters with Laser Scanning Confocal Microscopy (LSCM) before and after insertion (AI). Implant macrogeometry was characterized by LSCM. The chemical composition of bone beds was determined by SEM associated with Energy Dispersive X-Ray Spectroscopy. The amount of Ti released was analyzed with Energy Dispersive X-Ray Fluorescence. Alvim had greater IT and ISQ than Facility. Bone types I-II require higher IT of implants. Alvim also had greater internal threads angle, higher initial roughness, and significant reduction of roughness AI, compared to Facility. The functional surface height reduced AI, especially in flank and valley of threads. Height of surface roughness of Alvim and Facility implants was similar AI. Implants surface morphology changes and metallic particles on bone beds were observed after implant insertion, mainly into bone types III-IV. Implants inserted into bone types I-II showed less surface damage. Alvim implants released more Ti (37.52 ± 25.03 ppm) than Facility (11.66 ± 28.55 ppm) on bone types III-IV. The implant macrogeometry and bone types affect IT, ISQ, surface damage, and Ti amount released during insertion. Alvim implants were more wear susceptible, releasing higher Ti concentration during insertion into bone types III-IV.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (83)

Show source-provided references
1. The effect of thread pattern upon implant osseointegration10.1111/j.1600-0501.2009.01800.x ↗
2. Can osseointegration Be achieved without primary stability?
3. Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man10.3109/17453678108991776 ↗
4. Influence of surface roughness and shape on microdamage of the osseous surface adjacent to titanium dental implants10.1111/j.1600-0501.2010.02024.x ↗
5. Comparison between inflammation-related markers in peri-implant crevicular fluid and clinical parameters during osseointegration in edentulous jaws10.1007/s00784-017-2169-0 ↗
6. Biomaterial and biomechanical considerations to prevent risks in implant therapy10.1111/prd.12288 ↗
7. Osseointegration of titanium, titanium alloy and zirconia dental implants: current knowledge and open questions10.1111/prd.12179 ↗
8. Bone quality and quantity and dental implant failure: a systematic review and meta-analysis10.11607/ijp.5142 ↗
9. The effect of different implant macrogeometries and surface treatment in early biomechanical fixation: an experimental study in dogs10.1016/j.jmbbm.2011.06.016 ↗
10. Titanium particles in tissues from peri-implant mucositis: an exfoliative cytology-based pilot study10.4103/jisp.jisp_184_16 ↗
11. Surface morphology analysis of dental implants following insertion into bone using scanning electron microscopy: a pilot study10.1111/clr.12449 ↗
12. Dental implant surfaces after insertion in bone: an in vitro study in four commercial implant systems10.1007/s00784-017-2262-4 ↗
13. Peri-implant health and disease. A systematic review of current epidemiology10.1111/jcpe.12334 ↗
14. A comparison of maxillary and mandibular bone mineral densities10.1016/S0022-3913(98)70245-8 ↗
15. Improvement in the initial implant stability quotient through use of a modified surgical technique10.1563/aaid-joi-D-16-00159 ↗
16. Pro-inflammatory analysis of macrophages in contact with titanium particles and porphyromonas gingivalis10.1590/0103-6440201701382 ↗
17. Modeling dental implant insertion10.1016/j.jmbbm.2017.01.021 ↗
18. The effects of superficial roughness and design on the primary stability of dental implants10.1111/j.1708-8208.2009.00202.x ↗
19. Histological, histomorphometrical, and radiological evaluation of an experimental implant design with a high insertion torque10.1111/j.1600-0501.2010.01895.x ↗
20. Relationship between surface properties (roughness, wettability and morphology) of titanium and dental implant removal torque10.1016/j.jmbbm.2007.12.002 ↗
21. Influence of implant shape, surface morphology, surgical technique and bone quality on the primary stability of dental implants10.1016/j.jmbbm.2012.10.010 ↗
22. Mechanical and clinical properties of titanium and titanium-based alloys (Ti G2, Ti G4 cold worked nanostructured and Ti G5) for biomedical applications10.1016/j.jmrt.2018.07.016 ↗
23. Correlation between implant geometry, implant surface, insertion torque, and primary stability: in vitro biomechanical analysis10.11607/jomi.6285 ↗
24. Early detachment of titanium particles from various different surfaces of endosseous dental implants10.1016/j.biomaterials.2003.09.017 ↗
25. Prevalence of subjects with progressive bone loss at implants10.1111/j.1600-0501.2005.01137.x ↗
26. Metal elements in tissue with dental peri-implantitis: a pilot study10.1111/clr.12718 ↗
27. Is metal particle release associated with peri-implant bone destruction? An emerging concept10.1177/0022034517740560 ↗
28. Marginal bone loss as success criterion in implant dentistry: beyond 2 mm10.1111/clr.12324 ↗
29. Gasiecki · 1980 · 99
30. Dynamic modelling and simulation of dental implant insertion process - a finite element study10.1016/j.finel.2011.03.005 ↗
31. Research on implants and osseointegration10.1111/prd.12254 ↗
32. Analysis of titanium and other metals in human jawbones with dental implants - a case series study10.1016/j.dental.2016.05.012 ↗
33. Bone stability around dental implants: treatment related factors10.1016/j.aanat.2015.02.004 ↗
34. Effect of thread depth and implant shape on stress distribution in anterior and posterior regions of mandible bone: a finite element analysis10.4103/1735-3327.255745 ↗
35. Inczédy · 2000
36. Abrasion of surface components in endosseous implants depending on their shape and coating10.1016/S0901-5027(05)80034-7 ↗
37. Krug · 2016
38. Patient selection and preparation
39. Significance of primary stability for osseointegration of dental implants10.1111/j.1600-0501.2005.01201.x ↗
40. Titanium ion induces necrosis and sensitivity to lipopolysaccharide in gingival epithelial-like cells10.1016/j.tiv.2010.07.023 ↗
41. Implant thread designs: an overview
42. One-year clinical outcomes of locking taper Equator attachments retaining mandibular overdentures to narrow diameter implants10.1111/cid.12605 ↗
43. Mini-implants and narrow diameter implants as mandibular overdenture retainers: a systematic review and meta-analysis of clinical and radiographic outcomes10.1111/joor.12585 ↗
44. Effect of titanium surface roughness on proliferation, differentiation, and protein synthesis of human osteoblast-like cells (MG63)10.1002/jbm.820290314 ↗
45. Effect of surgical installation of dental implants on surface topography and its influence on osteoblast proliferation
46. Integrity of implant surface modifications after insertion10.11607/jomi.3259 ↗
47. Influence of cortical bone thickness and implant length on implant stability at the time of surgery-clinical, prospective, biomechanical, and imaging study10.1016/j.bone.2005.06.019 ↗
48. Effect of macrogeometry on the surface topography of dental implants10.11607/jomi.3934 ↗
49. Mechanical biocompatibilities of titanium alloys for biomedical applications10.1016/j.jmbbm.2007.07.001 ↗
50. Can degradation products released from dental implants affect peri-implant tissues?10.1111/jre.12479 ↗
51. ISO 11562:1996, Metrological Characterization of Phase Correct Filters and Transmission Bands for Use in Contact (Stylus) Instruments, International Organization for Standardization, Geneva, 1993.
52. ISO 25178-6:2010, M Geometrical product specifications (GPS) - Surface texture: Areal - Part 6: Classification of methods for measuring surface texture, European Standard, United Kingdom, 2010.
53. Corrosion resistance, mechanical properties, corrosion fatigue strength and cytocompatibility of new Ti alloys without Al and V10.1016/S0142-9612(97)00235-4 ↗
54. Oral mucosa tissue response to titanium cover screws10.1902/jop.2011.110392 ↗
55. Implant loading protocols for edentulous patients with fixed prostheses: a systematic review and meta-analysis10.11607/jomi.2014suppl.g4.3 ↗
56. Biocompatible implant surface treatments10.4103/0970-9290.102240 ↗
57. Titanium ions form particles that activate and execute interleukin-1β release from lipopolysaccharide-primed macrophages10.1111/jre.12364 ↗
58. Release of titanium after insertion of dental implants with different surface characteristics – an ex vivo animal study10.1080/23337931.2017.1399270 ↗
59. Unravelling the effect of macro and microscopic design of dental implants on osseointegration: a randomised clinical study in minipigs10.1007/s10856-018-6101-1 ↗
60. The influence of surface treatment on the implant roughness pattern10.1590/S1678-77572012000500010 ↗
61. Increased levels of dissolved titanium are associated with peri-implantitis - a cross-sectional study10.1902/jop.2016.160524 ↗
62. Metal release from titanium fixtures during placement in the mandible: an experimental study
63. Surface damage on dental implants with release of loose particles after insertion into bone10.1111/cid.12167 ↗
64. The proportion of cancellous bone as predictive factor for early marginal bone loss around implants in the posterior part of the mandible10.1111/clr.12398 ↗
65. Influence of high insertion torque on implant placement: an anisotropic bone stress analysis10.1590/S0103-64402010000600005 ↗
66. The role of cytokines in inflammatory bone loss10.3109/08820139.2013.822766 ↗
67. In vitro evaluation of titanium exfoliation during simulated surgical insertion of dental implants10.1563/aaid-joi-D-14-00230 ↗
68. Primary stability of cylindrical and conical dental implants in relation to insertion torque-A comparative ex vivo evaluation10.1097/ID.0000000000000531 ↗
69. Dental implant design and its relationship to long-term implant success10.1097/01.ID.0000091140.76130.A1 ↗
70. Biomechanical, biologic, and clinical outcomes of undersized implant surgical preparation: a systematic review10.11607/jomi.5340 ↗
71. Evaluation of the surface damage of dental implants caused by different surgical protocols: an in vitro study10.1016/j.ijom.2018.12.009 ↗
72. Characterization of a synthetic foam as a model for human cancellous bone10.1002/jab.770040309 ↗
73. Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: a laboratory study10.1111/j.1600-0501.2008.01692.x ↗
74. Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study10.1111/j.1600-0501.2009.01823.x ↗
75. Investigation of titanium leak to bone tissue surrounding dental titanium implant: electron microscopic findings and analysis by electron diffraction10.1007/s007950070008 ↗
76. Dental implant macro-design features can impact the dynamics of osseointegration10.1111/cid.12178 ↗
77. Release of titanium ions from an implant surface and their effect on cytokine production related to alveolar bone resorption10.1016/j.tox.2014.10.016 ↗
78. Suggested guidelines for the topographic evaluation of implant surfaces
79. Effects of titanium surface topography on boné integration: a systematic review10.1111/j.1600-0501.2009.01775.x ↗
80. Titanium release from implants prepared with different surface roughness10.1111/j.1600-0501.2004.01053.x ↗
81. Foreign bodies associated with peri-implantitis human biopsies10.1902/jop.2014.140363 ↗
82. Implant design and stress distribution
83. ASTM F1839 – 08 - Standard Specification for Rigid Polyurethane Foam for Use as a Standard Material for Testing Orthopaedic Devices and Instruments