Biotribological properties at the stem–cement interface lubricated with different media
Source abstract
Abstract
Background Debonding of the stem-cement interface occurs inevitably in-vivo under physiological loading, and pseudo-synovial fluid is subsequently pumped into this interface, serving as the lubricant. However, the influence of protein adsorption onto the femoral stem surface has not been well taken into consideration in previous in vitro studies. Materials and methods The biotribological properties at the stem-cement interface were investigated through a series of fretting frictional tests using polished stainless steel 316L stem and smooth bone cement, lubricated by three different media at body temperature, i.e. 100% calf serum, 25% calf serum, and 0.9% saline solution. The surface characterization of the femoral stem was evaluated sequentially using optical microscope, optical interferometer, scanning electron microscope, and Raman spectroscopy. Results The friction coefficient generally kept stable during the test, and the minimum value (0.254) was obtained when 100% calf serum was used as the lubricant. Slight scratches were detected within the contact area for the stainless steel 316L stems lubricated by 100% calf serum and 25% calf serum, which was further surrounded by the adsorbed protein film with alveolate feature. Additionally, a wear scar was present within the contact area when 0.9% saline solution was used as the lubricant. Conclusions Protein adsorption onto the stainless steel 316L stem surface affected the biotribological properties at the stem-cement interface under oscillatory fretting mechanism. Generation of wear debris at the stem-cement interface may be postponed by modification of physicochemical properties of the femoral stem to promote protein adsorption.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Osteoarthritis Treatment and Mechanisms
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. What results in fretting wear on polished femoral stems10.1016/j.triboint.2008.11.007 ↗
2. A review of lubrication conditions for wear simulation in artificial hip replacements10.1080/05698190500519223 ↗
3. Reproduction of fretting wear at the stem–cement interface in total hip replacement10.1243/09544119JEIM333 ↗
4. Effect of albumin adsorption on friction between artificial joint materials10.1243/13506501JET371 ↗
5. Friction, lubrication, and polymer transfer between UHMWPE and CoCrMo hip implant materials: a fluorescence microscopy study10.1002/jbm.a.32036 ↗
6. Fretting-corrosion of materials used as orthopaedic implants10.1016/j.wear.2004.11.027 ↗
7. Friction and wear mechanisms in hip prosthesis: comparison of joint materials behavior in several lubricants10.1016/j.wear.2004.12.040 ↗
8. Long term registration has improved the quality of hip replacement: a review of the Swedish THR Register comparing 160,000 cases10.1080/000164700317413067 ↗
9. How is the surface treatments influence on the roughness of biocompatibility?
10. The initiation of failure in cemented femoral components of hip arthroplasties
11. The effect of protein adsorption on the friction behavior of ultra-high molecular weight polyethylene10.1007/s11249-006-9078-8 ↗
12. Ellipsometry studies of the effects of surface hydrophobicity on protein adsorption10.1016/0927-7765(94)01139-V ↗
13. Friction and lubricant film thickness measurements on simulated synovial fluids10.1243/13506501JET580 ↗
14. Review: on the adsorption of proteins on solid surfaces, a common but very complicated phenomenon10.1016/S1389-1723(01)80127-4 ↗
15. Stem surface roughness alters creep induced subsidence and ‘taper-lock’ in a cemented femoral hip prosthesis10.1016/S0021-9290(01)00085-9 ↗
16. Role of salts on BSA adsorption on stainless steel in aqueous solutions. I. FT-IRRAS and XPS characterization10.1002/sia.1250 ↗
17. The adsorption and lubrication behavior of synovial fluid proteins and glycoproteins on the bearing-surface materials of hip replacements10.1016/j.biomaterials.2008.12.062 ↗
18. The significance of stem–cement loosening of grit-blasted femoral components10.3928/0147-7447-20001101-14 ↗
19. The effect of proteins on the friction and lubrication of artificial joints10.1243/09544119JEIM21 ↗
20. Wen · 201110.1002/9781118062913 ↗
21. Influence of polymer surface chemistry on frictional properties under protein-lubrication conditions: implication for hip implant design10.1023/A:1009074228662 ↗
22. Review article: femoral stem wear in cemented total hip replacement10.1243/09544119JEIM346 ↗
23. The significance of the micropores at the stem–cement interface in total hip replacement10.1163/092050610X540495 ↗
24. Investigation of relative micromotion at the stem–cement interface in total hip replacement10.1243/09544119JEIM594 ↗
25. Static shear strength between polished stem and seven commercial acrylic bone cements
26. Influence of femoral stem surface finish on the apparent static shear strength at the stem–cement interface10.1016/j.jmbbm.2007.06.001 ↗
27. Understanding initiation and propagation of fretting wear on the femoral stem in total hip replacement10.1016/j.wear.2008.04.076 ↗
28. The contribution of the micropores in bone cement surface to generation of femoral stem wear in total hip replacement10.1016/j.triboint.2010.11.007 ↗
29. The influence of bone cement type on production of fretting wear on the femoral stem surface10.1016/j.clinbiomech.2012.02.008 ↗
30. Zhang, H.Y., Zhang, S.H., Luo, J.B., Liu, Y.H., Qian, S.H., Liang, F.H., Huang, Y.L. Investigation of protein adsorption mechanism and biotribological properties at simulated stem–cement interface. Journal of Tribology, Transactions of ASME, in press.