Retention and wear of resin matrix attachments for implant overdentures

Niklas Wichmann, Matthias Kern, Thomas Taylor, Sebastian Wille, Nicole Passia

Publisher page

Abstract

Objectives The aim of the present laboratory study was to investigate the retentive properties and the wear of three different resin matrix attachments for implant overdentures as well as to assess the effects of implant angulation. Methods and materials Three attachment systems with either polyetheretherketone inserts (PEEK; Novaloc, Straumann, Basel, Switzerland), polyetherketoneketone inserts (PEKK; CM Loc, Cendres + Métaux, Biel, Switzerland) or nylon inserts (Locator R-Tx, Zest Dental Solutions, Escondido, California, USA) were evaluated. The patrices were connected to their implant analogues and fixed in a resin cast at implant angulations of 0° and 15°. The corresponding matrices with inserts were fixed in a stylized unilaterally removable dental prothesis. To simulate masticatory forces 30,000 insertion and removal cycles with an eccentric load of 100 N at a distance of 12 mm were performed in a chewing simulator. The retention forces were measured. The wear patterns were examined using a scanning electron microscope (SEM). The statistical analysis was performed using a one-way ANOVA followed by a Games-Howell test and a Friedman test. Results All attachment systems revealed a significant decrease in retention after testing, except PEEK 0°/0° and PEEK 15°/15°. PEEK and PEKK attachment systems showed significantly higher retentive forces than the nylon attachment system between 5000 and 30,000 cycles. The implant angulation did not significantly influence the retention behavior for any of the three attachment systems. Patrices showed no signs of wear, whereas the matrix inserts displayed signs of deformation. Conclusion Within the limitations of the present study, attachments with PEEK and PEKK inserts combined with titanium patrices are favorable for long-term use, both for orthogonal and tilted implants. All three attachment systems showed a high variability of the retentive forces at baseline and for subsequent cycles. This should be taken into consideration for clinical use.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (48)

Show source-provided references
1. The in vitro effect of different implant angulations and cyclic dislodgement on the retentive properties of an overdenture attachment system10.1016/S0022-3913(09)60134-7 ↗
2. Attachment systems for mandibular two-implant overdentures: a review of in vitro investigations on retention and wear features
3. Comparative study of four retentive anchor systems for implant supported overdentures - retention force changes10.1111/j.1741-2358.2009.00286.x ↗
4. Clinical long-term study of complete denture wearers10.1016/0022-3913(85)90066-6 ↗
5. In vitro retention force changes of prefabricated attachments for overdentures10.1046/j.1365-2842.2003.01140.x ↗
6. Improving masticatory performance, bite force, nutritional state and patient's satisfaction with implant overdentures: a systematic review of the literature10.1111/joor.12241 ↗
7. Biomechanics of polyaryletherketone rod composites and titanium rods for posterior lumbosacral instrumentation. Presented at the 2010 Joint Spine Section Meeting. Laboratory investigation10.3171/2010.5.SPINE09948 ↗
8. Retentive properties of two stud attachments with polyetherketoneketone or nylon insert in mandibular implant overdentures10.11607/jomi.6023 ↗
9. Stud attachments for the mandibular implant-retained overdentures: prosthetic complications. A literature review10.1016/j.sdentj.2012.12.003 ↗
10. Effect of distal implant inclination on dislodging forces of different locator attachments used for mandibular overdentures: an in-vitro study
11. The change in retentive values of locator attachments and hader clips over time10.1111/j.1532-849X.2009.00474.x ↗
12. The McGill consensus statement on overdentures. Montreal, Quebec, Canada. May 24-25, 2002
13. Resin bonding to three types of polyaryletherketones (PAEKs)-durability and influence of surface conditioning10.1016/j.dental.2013.12.008 ↗
14. Clinical complications in fixed prosthodontics10.1016/S0022-3913(03)00214-2 ↗
15. Implant-supported mandibular overdentures retained with ball or bar attachments: a randomized prospective 5-year study
16. Implant- and tooth-supported fixed prostheses using a high-performance polymer (pekkton) framework10.11607/ijp.4688 ↗
17. A systematic review and meta-analysis of removable and fixed implant-supported prostheses in edentulous jaws: post-loading implant loss10.1111/clr.12531 ↗
18. Correcting a nonparallel implant abutment for a mandibular overdenture retained by two implants: a clinical report10.1016/j.prosdent.2004.06.019 ↗
19. Comparison of changes in retentive force of three stud attachments for implant overdentures10.4047/jap.2015.7.4.303 ↗
20. A comparison of three different attachment systems for mandibular two-implant overdentures: one-year report10.1111/j.1708-8208.2009.00154.x ↗
21. Effects of in vitro cyclic dislodging on retentive force and removal torque of three overdenture attachment systems10.1111/clr.12156 ↗
22. Posterior mandibular residual ridge resorption in patients with conventional dentures and implant overdentures
23. An international survey among prosthodontists of the use of mandibular implant-supported dental prostheses10.1111/jopr.12603 ↗
24. PEEK biomaterials in trauma, orthopedic, and spinal implants10.1016/j.biomaterials.2007.07.013 ↗
25. Splinted and unsplinted overdenture attachment systems: a systematic review and meta-analysis10.1111/joor.12651 ↗
26. In vitro retention force changes during cyclic dislodging of three novel attachment systems for implant overdentures with different implant angulations10.1111/clr.13567 ↗
27. Implant-supported mandibular overdentures in very old adults: a randomized controlled trial10.1177/0022034513509630 ↗
28. Long-term retention behaviour of resin matrix attachment systems for overdentures10.1016/j.jmbbm.2015.11.038 ↗
29. The service life of implant-retained overdenture attachment systems10.1016/S0022-3913(09)60112-8 ↗
30. A systematic review of the survival and complication rates of implant-supported fixed dental prostheses (FDPs) after a mean observation period of at least 5 years10.1111/j.1600-0501.2012.02546.x ↗
31. Microbiological and clinical outcomes and patient satisfaction for two treatment options in the edentulous lower jaw after 10 years of function10.1111/j.1600-0501.2005.01127.x ↗
32. Denture use and the technical quality of dental prostheses among persons 18-74 years of age: United States, 1988-199110.1177/002203459607502S11 ↗
33. Influence of attachment wear on retention of mandibular overdenture10.1111/j.1365-2842.2006.01640.x ↗
34. Wear simulation effects on overdenture stud attachments10.4012/dmj.2011-057 ↗
35. Effects of interimplant distance and cyclic dislodgement on retention of Locator and ball attachments: an in vitro study10.1016/j.prosdent.2018.12.023 ↗
36. Comparison of retention and stability of two implant-retained overdentures based on implant location10.1016/j.prosdent.2014.03.003 ↗
37. Bar overdentures utilizing the locator attachment
38. Retention of prefabricated attachments for implant stabilized overdentures in the edentulous mandible: an in vitro study10.1016/S0022-3913(98)70133-7 ↗
39. The influence of interimplant divergence on the retention characteristics of locator attachments, a laboratory study10.1111/jopr.12144 ↗
40. The effect of inter-implant distance on retention and resistance to dislodging forces for mandibular implant-tissue-supported overdentures
41. Patient satisfaction with mandibular implant overdentures and conventional dentures 6 months after delivery
42. Polyetheretherketone as a biomaterial for spinal applications10.1016/j.biomaterials.2005.07.011 ↗
43. Attachment systems for implant retained overdentures: a literature review10.1097/01.id.0000202419.21665.36 ↗
44. In vitro comparison of the retentive properties of ball and locator attachments for implant overdentures10.11607/jomi.3621 ↗
45. The influence of clinical variables on patients' satisfaction with complete dentures10.1016/0022-3913(90)90202-N ↗
46. Implant angulation: a measurement technique, implant overdenture maintenance, and the influence of surgical experience
47. Implantology in the endentulous patients - an update after 25 years
48. Attachment systems for implant overdenture: influence of implant inclination on retentive and lateral forces10.1111/j.1600-0501.2010.02137.x ↗