journal article·2021-01

Stress and strain distribution in femoral heads for hip resurfacing arthroplasty with different materials: A finite element analysis

Danny Vogel, Merle Wehmeyer, Maeruan Kebbach, Horst Heyer, Rainer Bader

Publisher page

Abstract

Femoral bone loss due to stress and strain shielding is a common problem in hip resurfacing arthroplasty (HRA), which arises from the different stiffness of implant materials and the adjacent bone. Usually, the implants used in HRA are made of cobalt-chromium alloy (CoCr). As a novel concept, implants may also be made of ceramics, whose stiffness exceeds that of the adjacent bone by a multiple. Therefore, this computational study aimed to evaluate whether poly (ether-ether-ketone) (PEEK) or a hybrid material with a PEEK body and ceramic surface made of alumina toughened zirconia (ATZ) might be more suitable implant alternatives for HRA, as they can avoid stress and strain shielding. A reconstructed model of a human femur with an HRA implant was simulated, whereby the material of the HRA was varied between CoCr, ATZ, zirconia toughened alumina (ZTA), PEEK, and a hybrid PEEK-ATZ material. The implant fixation method also varied (cemented or cementless). The simulated models were compared with an intact model to analyze stress and strain distribution in the femoral head and neck. The strain distribution was evaluated at a total of 30,344 (cemented HRA) and 63,531 (uncemented HRA) nodes in the femoral head and neck region and divided into different strain regions (<400 µm/m: atrophy; 400-3000 μm/m: bone preserving and building; 3000-20,000 μm/m: yielding and >20,000 μm/m fracture). In addition, the mechanical stability of the implants was evaluated. When the material of the HRA implant was simulated as metal or ceramic while evaluating the strains, it was seen that around 22-26% of the analyzed nodes in the femoral head and neck were in an atrophic region, 47-51% were in a preserving or building region, and 27-28% were in a yielding region. In the case of PEEK implant, less than 0.5% of the analyzed nodes were in an atrophic region, 66-69% in a preserving or building region, and 31-34% in a yielding region. The fixation technique also had a small influence. When a hybrid HRA was simulated, the strains at the analyzed nodes depended on the thickness of the ceramic material. In conclusion, the material of the HRA implant was crucial in terms of stress and strain distribution in the adjacent bone. HRA made of PEEK or a hybrid material leads to decisively reduced stress and strain alteration compared to stiffer materials such as CoCr, ATZ, and ZTA. This confirms the potential for reduction in stress and strain shielding in the femoral head with the use of a hybrid material with a PEEK body for HRA.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Total Knee Arthroplasty Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (70)

Show source-provided references
1. Early results of conversion of a failed femoral component in hip resurfacing arthroplasty10.2106/00004623-200704000-00006 ↗
2. ATZ – a new material with a high potential in joint replacement10.4028/www.scientific.net/KEM.284-286.983 ↗
3. Standardized loads acting in hip implants10.1371/journal.pone.0155612 ↗
4. Safety factors in bone strength10.1007/BF01673406 ↗
5. Wear of ceramic-on-carbon fiber-reinforced poly-ether ether ketone hip replacements10.1002/jbm.b.32664 ↗
6. Bone mineral density of the proximal femur recovers after metal-on-metal hip resurfacing
7. Finite element analysis of the contact mechanics of ceramic-on-ceramic hip resurfacing prostheses10.1016/S1672-6529(10)60247-8 ↗
8. Early clinical results of an anatomic cementless ceramic HIP resurfacing arthroplasty
9. Anatomic ceramic HIP resurfacing arthroplasty: first IN human trials
10. In situ parameter identification of optimal density-elastic modulus relationships in subject-specific finite element models of the proximal femur10.1016/j.medengphy.2010.09.018 ↗
11. Ten-year results of a double-heat-treated metal-on-metal hip resurfacing10.1302/0301-620X.92B1.21530 ↗
12. An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements10.2106/JBJS.C.00949 ↗
13. Pre-clinical evaluation of ceramic femoral head resurfacing prostheses using computational models and mechanical testing10.1177/0954411911411605 ↗
14. The influence of acetabular cup material on pelvis cortex surface strains, measured using digital image correlation10.1016/j.jbiomech.2011.11.042 ↗
15. Feasibility and safety of a cemented PEEK-on-PE knee replacement in a goat model: a preliminary study10.1111/aor.13101 ↗
16. An investigation to determine if a single validated density-elasticity relationship can be used for subject specific finite element analyses of human long bones10.1016/j.medengphy.2012.08.022 ↗
17. F04 Committee. Specification for Cobalt-28 Chromium-6 Molybdenum Alloy Castings and Casting Alloy for Surgical Implants (UNS R30075); ASTM International: West Conshohocken, PA.
18. The long-term mechanical integrity of non-reinforced PEEK-OPTIMA polymer for demanding spinal applications: experimental and finite-element analysis10.1007/s00586-005-0915-5 ↗
19. Bone's mechanostat: a 2003 update10.1002/ar.a.10119 ↗
20. Neuro-musculoskeletal flexible multibody simulation yields a framework for efficient bone failure risk assessment10.1038/s41598-019-43028-6 ↗
21. Stress shielding in cemented hip implants assessed from computed tomography10.26717/BJSTR.2019.18.003163 ↗
22. Biotribology of alternative bearing materials for unicompartmental knee arthroplasty10.1016/j.actbio.2010.04.003 ↗
23. Ceramic acetabular liner fracture in total hip arthroplasty with a ceramic sandwich cup10.1016/S0883-5403(03)00193-1 ↗
24. Musculo-skeletal loading conditions at the hip during walking and stair climbing10.1016/S0021-9290(01)00039-2 ↗
25. Preservation of the bone mineral density of the femur after surface replacement of the hip10.1302/0301-620X.86B2.14338 ↗
26. A convenient approach for finite-element-analyses of orthopaedic implants in bone contact: modeling and experimental validation10.1016/j.cmpb.2009.01.004 ↗
27. A round-robin finite element analysis of human femur mechanics between seven participating laboratories with experimental validation10.1080/10255842.2019.1615481 ↗
28. PEEK biomaterials in trauma, orthopedic, and spinal implants10.1016/j.biomaterials.2007.07.013 ↗
29. Blood metal ion concentrations after hip resurfacing arthroplasty: a comparative study of articular surface replacement and Birmingham Hip Resurfacing arthroplasties10.1302/0301-620X.91B10.22308 ↗
30. The relationship of sporting activity and implant survivorship after hip resurfacing10.2106/JBJS.K.00100 ↗
31. Compressive creep characteristics of extruded ultrahigh-molecular-weight polyethylene10.1002/(SICI)1097-4636(199802)39:2<261::AID-JBM13>3.0.CO;2-G ↗
32. Changes of the bone mineral density in proximal femur following total hip resurfacing arthroplasty in osteonecrosis of femoral head10.1002/jor.20503 ↗
33. The Birmingham hip resurfacing prosthesis: an independent single surgeon's experience at 7-year follow-up10.1016/j.arth.2009.10.010 ↗
34. Ceramics and ceramic coatings in orthopaedics10.1016/j.jeurceramsoc.2015.07.034 ↗
35. Characteristics of wear particles and wear behavior of retrieved PEEK-on-HXLPE total knee implants: a preliminary study10.1039/C8RA04661A ↗
36. In vivo implant fixation of carbon fiber-reinforced PEEK hip prostheses in an ovine model10.1002/jor.22251 ↗
37. Failure analysis of sandwich-type ceramic-on-ceramic hip joints: a spectroscopic investigation into the role of the polyethylene shell component10.1016/j.jmbbm.2013.01.022 ↗
38. The birmingham hip resurfacing: 5-year clinical and radiographic results from a district general hospital10.1007/s00264-009-0821-2 ↗
39. Biomechanics of the Birmingham hip resurfacing arthroplasty10.1302/0301-620X.88B8.17567 ↗
40. Role of surgical position on interface stress and initial bone remodeling stimulus around hip resurfacing arthroplasty10.1016/j.arth.2008.08.005 ↗
41. Hip resurfacing: a systematic review of literature10.1007/s00264-012-1686-3 ↗
42. A numerical study of failure mechanisms in the cemented resurfaced femur: effects of interface characteristics and bone remodelling10.1243/09544119JEIM488 ↗
43. Design considerations for ceramic resurfaced femoral head: effect of interface characteristics on failure mechanisms10.1080/10255840903067064 ↗
44. Ceramic failure after total hip arthroplasty with an alumina-on-alumina bearing
45. Influence of polyethylene creep behavior on wear in total hip arthroplasty10.1002/jor.20042 ↗
46. Metal-on-metal hip resurfacing: advantages and disadvantages10.1016/j.arth.2008.06.015 ↗
47. Investigation into the affect of cementing techniques on load transfer in the resurfaced femoral head: a multi-femur finite element analysis10.1016/j.clinbiomech.2006.12.001 ↗
48. 2014
49. A preclinical numerical assessment of a polyetheretherketone femoral component in total knee arthroplasty during gait10.1186/s40634-017-0078-4 ↗
50. Carbon-nanofibre-reinforced poly(ether ether ketone) composites10.1016/S1359-835X(02)00084-2 ↗
51. The wear properties of CFR-PEEK-OPTIMA articulating against ceramic assessed on a multidirectional pin-on-plate machine10.1243/09544119JEIM224 ↗
52. Pitch-based carbon-fibre-reinforced poly (ether-ether-ketone) OPTIMA assessed as a bearing material in a mobile bearing unicondylar knee joint10.1243/09544119JEIM471 ↗
53. Wear studies on the likely performance of CFR-PEEK/CoCrMo for use as artificial joint bearing materials10.1007/s10856-008-3558-3 ↗
54. Tribological assessment of a flexible carbon-fibre-reinforced poly(ether-ether-ketone) acetabular cup articulating against an alumina femoral head10.1243/09544119JEIM334 ↗
55. Finite-Elemente-Analyse einer zementierten, keramischen Femurkomponente unter Berücksichtigung der Einbausituation bei künstlichem Kniegelenkersatz10.1515/BMT.2007.051 ↗
56. Femoral neck fractures following Birmingham hip resurfacing: a national review of 50 cases10.1302/0301-620X.87B4.15498 ↗
57. Physiologically based boundary conditions in finite element modelling10.1016/j.jbiomech.2006.10.038 ↗
58. The biologic response to polyetheretherketone (PEEK) wear particles in total joint replacement: a systematic review10.1007/s11999-016-4976-z ↗
59. Long-term implant fixation and stress-shielding in total hip replacement10.1016/j.jbiomech.2014.12.021 ↗
61. Fractures of a sandwich ceramic liner at ten year follow-up10.1007/s00264-011-1375-7 ↗
62. Biomechanical behavior of modular acetabular cups made of poly-ether-ether-ketone: a finite element study10.1177/0954411918797600 ↗
63. Mechanical and numerical characterization of ceramic femoral components for hip resurfacing arthroplasty10.1177/0954411919855296 ↗
64. Influence of the acetabular cup material on the shell deformation and strain distribution in the adjacent bone-A finite element analysis10.3390/ma13061372 ↗
65. Carbon fiber reinforced polyether ether ketone composite as a bearing surface for total hip replacement10.1016/S0301-679X(98)00088-7 ↗
66. Biotribological study of large diameter ceramic-on-CFR-PEEK hip joint including fluid uptake, wear and frictional heating10.1007/s10856-012-4617-3 ↗
67. Aseptic lymphocyte-dominated vasculitis-associated lesion: a clinicopathologic review of an underrecognized cause of prosthetic failure10.1309/AJCPLTNEUAH8XI4W ↗
68. Critical evaluation of known bone material properties to realize anisotropic FE-simulation of the proximal femur10.1016/S0021-9290(00)00069-5 ↗
69. Neo-capsule tissue reactions in metal-on-metal hip arthroplasty10.1080/17453670710013708 ↗
70. Zacharias · 2001