Characterization of the bone-metal implant interface by Digital Volume Correlation of in-situ loading using neutron tomography
Source abstract
Abstract
Metallic implants are commonly used as surgical treatments for many orthopedic conditions. The long-term stability of implants relies on an adequate integration with the surrounding bone. Unsuccessful integration could lead to implant loosening. By combining mechanical loading with high-resolution 3D imaging methods, followed by image analysis such as Digital Volume Correlation (DVC), we aim at evaluating ex vivo the mechanical resistance of newly formed bone at the interface. X-rays tomography is commonly used to image bone but induces artefacts close to metallic components. Utilizing a different interaction with matter, neutron tomography is a promising alternative but has not yet been used in studies of bone mechanics. This work demonstrates that neutron tomography during in situ loading is a feasible tool to characterize the mechanical response of bone-implant interfaces, especially when combined with DVC. Experiments were performed where metal screws were implanted in rat tibiae during 4 weeks. The screws were pulled-out while the samples were sequentially imaged in situ with neutron tomography. The images were analyzed to quantify bone ingrowth around the implants. DVC was used to track the internal displacements and calculate the strain fields in the bone during loading. The neutron images were free of metal-related artefacts, which enabled accurate quantification of bone ingrowth on the screw (ranging from 60% to 71%). DVC allowed successful identification of the deformation and cracks that occurred during mechanical loading and led to final failure of the bone-implant interface.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Nuclear Physics and Applications · Advanced X-ray and CT Imaging · Radioactivity and Radon Measurements
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (43)
Show source-provided references
1. Biomaterial strategies for engineering implants for enhanced osseointegration and bone repair10.1016/j.addr.2015.03.013 ↗
2. Characterization of the effects of x-ray irradiation on the hierarchical structure and mechanical properties of human cortical bone10.1016/j.biomaterials.2011.08.013 ↗
3. Artifacts in CT: recognition and avoidance10.1148/rg.246045065 ↗
4. Digital volume correlation: three-dimensional strain mapping using X-ray tomography10.1007/BF02323555 ↗
5. The Swiss Spallation Neutron Source SINQ at Paul Scherrer Institut10.1080/10448630903120387 ↗
6. CT artifacts: causes and reduction techniques10.2217/iim.12.13 ↗
7. Augmentation of autologous bone graft by a combination of bone morphogenic protein and bisphosphonate increased both callus volume and strength10.3109/17453674.2013.773123 ↗
8. Guidelines for assessment of bone microstructure in rodents using micro-computed tomography10.1002/jbmr.141 ↗
9. Nonlinear inverse scale space methods10.4310/CMS.2006.v4.n1.a7 ↗
10. BoneJ: free and extensible bone image analysis in ImageJ10.1016/j.bone.2010.08.023 ↗
11. Biomechanics and strain mapping in bone as related to immediately-loaded dental implants10.1016/j.jbiomech.2015.05.014 ↗
12. The application of digital volume correlation (DVC) to study the microstructural behaviour of trabecular bone during compression10.1016/j.jmbbm.2013.09.014 ↗
13. Extracting accurate strain measurements in bone mechanics: a critical review of current methods10.1016/j.jmbbm.2015.06.006 ↗
14. Hall, S.A., 2012. Digital image correlation in experimental geomechanics, In: ALERT Doctoral School 2012: Advanced Experimental Techniques in Geomechanics, Viggiani G., Halls S.A., Romero E. (Eds.). 〈http://upcommons.upc.edu/e-prints/bitstream/2117/18768/1/11698508.pdf#page=75〉 (accessed 25 September 2015).
15. Discrete and continuum analysis of localised deformation in sand using X-ray μCT and volumetric digital image correlation10.1680/geot.2010.60.5.315 ↗
16. Manipulating the anabolic and catabolic response in bone graft remodeling: synergism by a combination of local BMP-7 and a single systemic dosis of zoledronate10.1002/jor.20625 ↗
17. Effect of the quantity and quality of cortical bone on the failure force of a miniscrew implant10.1093/ejo/cjs066 ↗
18. Neutron tomographic imaging of bone-implant interface: comparison with X-ray tomography10.1016/j.bone.2017.07.022 ↗
19. Studies of Haversian systems in man and some animals
20. MuhRec – a new tomography reconstructor10.1016/j.nima.2011.01.129 ↗
21. The ICON beamline – a facility for cold neutron imaging at SINQ10.1016/j.nima.2011.08.022 ↗
22. Recent developments in neutron imaging with applications for porous media research10.5194/se-7-1281-2016 ↗
23. Processing neutron imaging data – quo vadis?10.1016/j.phpro.2015.07.047 ↗
24. Bone structure investigation using X-ray and neutron radiography techniques10.1016/j.apradiso.2007.07.011 ↗
25. Neutron imaging in materials science10.1016/S1369-7021(11)70139-0 ↗
26. Reconstructing the auditory apparatus of therapsids by means of neutron tomography10.1016/j.phpro.2015.07.089 ↗
27. Effects of dehydration-induced structural and material changes on the apparent modulus of cancellous bone10.1016/j.medengphy.2010.06.001 ↗
28. Weak effect of strontium on early implant fixation in rat tibia10.1016/j.bone.2011.10.034 ↗
29. Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular bone10.1016/j.jbiomech.2007.04.019 ↗
30. Investigating the synergistic efficacy of BMP-7 and zoledronate on bone allografts using an open rat osteotomy model10.1016/j.bone.2013.06.030 ↗
31. Characterising bone material composition and structure in the ovariectomized (OVX) rat model of osteoporosis10.1007/s00223-015-9991-7 ↗
32. Biomechanical determinants of the stability of dental implants: influence of the bone–implant interface properties10.1016/j.jbiomech.2013.09.021 ↗
33. Synchrotron μCT imaging of bone, titanium implants and bone substitutes – a systematic review of the literature10.1016/j.jcms.2013.11.015 ↗
34. Neutron imaging of hydrogen-rich fluids in geomaterials and engineered porous media: a review10.1016/j.earscirev.2013.11.012 ↗
35. Calcium sulphate/hydroxyapatite carrier containing bone morphogenic protein-2 and zoledronic acid generates bone10.1038/srep26033 ↗
36. Application of the digital volume correlation technique for the measurement of displacement and strain fields in bone: a literature review10.1016/j.jbiomech.2014.01.001 ↗
37. Neutron tomography of internal structures of vertebrate remains: a comparison with X-ray computed tomography
38. Designs and techniques that improve the pullout strength of pedicle screws in osteoporotic vertebrae: current status
39. Digital volume correlation and micro-CT: an in-vitro technique for measuring full-field interface micromotion around polyethylene implants10.1016/j.jbiomech.2015.05.024 ↗
40. Future prospects of imaging at spallation neutron sources accelerators10.1016/j.nima.2009.03.075 ↗
41. Progress in high-resolution neutron imaging at the Paul Scherrer Institut - The Neutron Microscope Project
42. Full-field measurements of strain localisation in sandstone by neutron tomography and 3D-volumetric digital image correlation10.1016/j.phpro.2015.07.072 ↗
43. The test beamline of the European Spallation Source – instrumentation development and wavelength frame multiplication10.1016/j.nima.2016.09.034 ↗