journal article·2018-01

Niobium treated by Plasma Electrolytic Oxidation with calcium and phosphorus electrolytes

Bruno Leandro Pereira, Aline Rossetto da Luz, Carlos Maurício Lepienski, Irineu Mazzaro, Neide Kazue Kuromoto

Publisher page

Abstract

Niobium plates were electrochemically treated by Plasma Electrolytic Oxidation (PEO) with electrolytes containing phosphorous and/or calcium. Three different electrolyte and experimental parameters were used forming three different surfaces. Film morphology, thickness, and chemical composition were analyzed by scanning electron microscopy (SEM), and energy dispersive spectroscopy (EDS). A profilometer and the sessile drop technique measured the average surfaces roughness (Ra) and contact angles respectively. X-ray diffraction technique (XRD) analyzed the oxide crystallinity, and scratch tests evaluated the film adhesion. All oxidized surfaces presented pores, without observed cracks. Comparing the different experimental conditions, films obtained with phosphoric acid (P100) show superficial pores, phosphorus incorporation, high hydrophilicity, non-crystalline oxide formation, and good scratch resistance. Films treated with calcium acetate electrolyte (Ca100), compared to P100 exhibit smaller size pores and film thickness, smaller hydrophilicity, and lower scratch resistance. They also demonstrated higher oxide crystallinity, calcium incorporation, and pores interconnections. When the PEO was executed with a blended electrolyte containing calcium acetate and phosphoric acid (Ca50P50) the formed films presented the highest thickness, high phosphorus incorporation, and the lowest contact angle compared with other films. In addition, the pores size, the scratch resistance, calcium incorporation, and oxide crystallinity present intermediate values compared to P100 and Ca100 films. Film crystallinity seems to be influenced by calcium incorporation, whereas, hydrophilicity is phosphorus amount dependent. The pores amount and their interconnections reduced the scratch resistance. Surface features obtained in this work are largely mentioned as positive characteristics for osseointegration processes.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Magnesium Alloys: Properties and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (52)

Show source-provided references
1. Biocompatibility of Ti-alloys for long-term implantation10.1016/j.jmbbm.2012.11.014 ↗
2. The effect of ultraviolet functionalization of titanium on integration with bone10.1016/j.biomaterials.2008.11.004 ↗
3. Osteoblast adhesion on biomaterials10.1016/S0142-9612(99)00242-2 ↗
4. Modulation of cell adhesion, proliferation and differentiation on materials designed for body implants10.1016/j.biotechadv.2011.06.004 ↗
5. Micro-arc oxidation of Ti6Al4V and Ti6Al7Nb alloys for biomedical applications10.1016/j.matchar.2011.01.002 ↗
6. Porosity in plasma electrolytic oxide coatings10.1016/j.actamat.2005.12.029 ↗
7. Davis · 2016
8. Calcium orthophosphate deposits: preparation, properties and biomedical applications10.1016/j.msec.2015.05.033 ↗
9. Cytotoxic, hematologic and histologic effects of niobium pentoxide in Swiss mice10.1007/s10856-014-5153-0 ↗
10. Nanostructured niobium oxide coatings influence osteoblast adhesion10.1002/jbm.a.30823 ↗
11. Superconducting elements10.1103/RevModPhys.26.277 ↗
12. Relationship between surface properties (roughness, wettability and morphology) of titanium and dental implant removal torque10.1016/j.jmbbm.2007.12.002 ↗
13. Surface & coatings technology formation of grooved and porous coatings on titanium by plasma electrolytic oxidation in H2SO4/H3PO4 electrolytes and effects of coating morphology on adhesive bonding10.1016/j.surfcoat.2015.02.036 ↗
14. Surface topography of dental implants: a review10.4103/0974-6781.131009 ↗
15. Surface characteristics of anodic oxidized titanium according to the pore size
16. TiO2 coatings in alkaline electrolytes using anodic oxidation technique10.1016/j.mspro.2015.04.049 ↗
17. Bioactivity of novel self-assembled crystalline Nb2O5 microstructures in simulated and human salivas10.1088/1748-6041/1/1/003 ↗
18. Formation of niobium oxide film with duplex layers by galvanostatic anodization10.5012/bkcs.2012.33.8.2675 ↗
19. Electrochemical surface modification of titanium in dentistry10.4012/dmj.28.20 ↗
20. How useful is SBF in predicting in vivo bone bioactivity?10.1016/j.biomaterials.2006.01.017 ↗
21. BMP-induced osteogenesis on the surface of hydroxyapatite with geometrically feasible and nonfeasible structures: topology of osteogenesis10.1002/(SICI)1097-4636(199802)39:2<190::AID-JBM4>3.0.CO;2-K ↗
22. Bone response to surface modified titanium implants – studies on the tissue response after 1 year to machined and electropolished implants with different oxide thicknesses10.1023/A:1018548225899 ↗
23. Improved biological performance of Ti implants due to surface modification by micro-arc oxidation10.1016/j.biomaterials.2003.09.048 ↗
24. Formation mechanism and adhesive strength of a hydroxyapatite/TiO2 composite coating on a titanium surface prepared by micro-arc oxidation10.1016/j.apsusc.2015.11.086 ↗
25. Surface nano-functionalization of biomaterials10.1016/j.mser.2010.06.013 ↗
26. Surface modification of titanium, titanium alloys, and related materials for biomedical applications10.1016/j.mser.2004.11.001 ↗
27. Production of hydroxyapatite layers on the plasma electrolytically oxidized surface of titanium alloys10.1016/j.msec.2014.07.030 ↗
28. Plasma electrolytic oxide coatings on valve metals and their activity in CO oxidation10.1016/j.apsusc.2014.03.040 ↗
29. Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium10.1016/S0142-9612(00)00275-1 ↗
30. Determination of structural, mechanical and corrosion properties of Nb2O5 and ( Nb y Cu 1 − y) O x thin films deposited on Ti6Al4V alloy substrates for dental implant applications10.1016/j.msec.2014.11.047 ↗
31. Apatite-forming ability of niobium oxide gels in a simulated body fluid10.2109/jcersj.109.1275_929 ↗
32. Mechanical biocompatibilities of titanium alloys for biomedical applications10.1016/j.jmbbm.2007.07.001 ↗
33. Recent metallic materials for biomedical applications10.1007/s11661-002-0109-2 ↗
34. The responses to surface wettability gradients induced by chitosan nanofilms on microtextured titanium mediated by specific integrin receptors10.1016/j.biomaterials.2012.06.066 ↗
35. Apatite grown in niobium by two-step plasma electrolytic oxidation
36. Titanium bioactivity surfaces obtained by chemical/electrochemical treatments
37. Investigating the structure and biocompatibility of niobium and titanium oxides as coatings for orthopedic metallic implants10.1016/j.msec.2015.09.059 ↗
38. Effect of different thermomechanical processing on structure and mechanical properties of electron beam melted niobium10.1007/s12666-009-0018-9 ↗
39. Hardness and elastic modulus of TiO2 anodic films measured by instrumented indentation10.1002/jbm.b.30900 ↗
40. Modification of niobium surfaces using plasma electrolytic oxidation in silicate solutions10.1007/s10008-013-2341-7 ↗
41. Bioactivity of coatings formed on Ti – 13Nb – 13Zr alloy using plasma electrolytic oxidation10.1016/j.msec.2014.12.073 ↗
42. Surface characterisation and corrosion behaviour of niobium treated in a Ca- A nd P-containing solution under sparking conditions10.1016/j.electacta.2016.03.069 ↗
43. Anodic luminescence, structural, photoluminescent, and photocatalytic properties of anodic oxide films grown on niobium in phosphoric acid10.1016/j.apsusc.2015.07.174 ↗
44. Etched implants: a comparative surface analysis of four implant systems10.1002/jbm.b.20021 ↗
45. Plasma electrolytic oxidation (PEO) for production of anodised coatings on lightweight metal (Al, Mg, Ti) alloys10.1179/174591908X372482 ↗
46. Review of the biocompatibility of micro-arc oxidation coated titanium alloys10.1016/j.matdes.2015.07.086 ↗
47. Ceramic coatings by anodic spark deposition10.1080/10426919108934737 ↗
48. Bonding of chemically treated titanium implants to bone10.1002/(SICI)1097-4636(199711)37:2<267::AID-JBM17>3.0.CO;2-B ↗
49. Preparation of bioactive titanium metal via anodic oxidation treatment10.1016/S0142-9612(03)00626-4 ↗
50. Plasma electrolysis for surface engineering10.1016/S0257-8972(99)00441-7 ↗
51. Anodic oxide films containing Ca and P of titanium biomaterial10.1016/S0142-9612(00)00394-X ↗
52. Enhancement of valve metal osteoconductivity by one-step hydrothermal treatment10.1016/j.msec.2014.05.049 ↗