Force delivery of NiTi orthodontic arch wire at different magnitude of deflections and temperatures: A finite element study
Source abstract
Abstract
NiTi arch wires are used widely in orthodontic treatment due to its superelastic and biocompatibility properties. In brackets configuration, the force released from the arch wire is influenced by the sliding resistances developed on the arch wire-bracket contact. This study investigated the evolution of the forces released by a rectangular NiTi arch wire towards possible intraoral temperature and deflection changes. A three dimensional finite element model was developed to measure the force-deflection behavior of superelastic arch wire. Finite element analysis was used to distinguish the martensite fraction and phase state of arch wire microstructure in relation to the magnitude of wire deflection. The predicted tensile and bending results from the numerical model showed a good agreement with the experimental results. As contact developed between the wire and bracket, binding influenced the force-deflection curve by changing the martensitic transformation plateau into a slope. The arch wire recovered from greater magnitude of deflection released lower force than one recovered from smaller deflection. In contrast, it was observed that the plateau slope increased from 0.66N/mm to 1.1N/mm when the temperature was increased from 26°C to 46°C.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Shape Memory Alloy Transformations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (28)
Show source-provided references
1. Shape-memory alloys: modelling and numerical simulations of the finite-strain superelastic behavior10.1016/S0045-7825(96)01147-4 ↗
2. Forces produced by different nonconventional bracket or ligature systems during alignment of apically displaced teeth10.2319/050508-249.1 ↗
3. A thermodynamical constitutive model for shape memory materials. Part I. The monolithic shape memory alloy10.1016/S0749-6419(96)00030-7 ↗
4. Duerig · 2013
5. Mechanical properties of coated superelastic archwires in conventional and self-ligating orthodontic brackets10.1016/j.ajodo.2008.01.026 ↗
6. Effect of ageing treatment on the deformation behaviour of Ti–50.9 at% Ni10.1016/j.actamat.2009.06.059 ↗
7. Aesthetic nickel titanium wires--how much do they deliver?10.1093/ejo/cjr089 ↗
8. Comparison of frictional forces during the initial leveling stage in various combinations of self-ligating brackets and archwires with a custom-designed typodont system10.1016/j.ajodo.2007.08.013 ↗
9. Influence of archwire and bracket dimensions on sliding mechanics: derivations and determinations of the critical contact angles for binding10.1093/ejo/21.2.199 ↗
10. Load deflection characteristics and force level of nickel titanium initial archwires10.2319/032511-213.1 ↗
11. Development of shape memory alloys10.2355/isijinternational.29.353 ↗
12. Relationship between friction force and orthodontic force at the leveling stage using a coated wire10.1590/1679-775720130325 ↗
13. Finite element modeling of superelastic nickel-titanium orthodontic wires10.1016/j.jbiomech.2014.10.007 ↗
14. Effects of material properties on mechanical performance of Nitinol stent designed for femoral artery: finite element analysis10.1016/j.scient.2012.10.024 ↗
15. Influence of bracket-slot design on the forces released by superelastic nickel-titanium alignment wires in different deflection configurations10.2319/060213-416.1 ↗
16. Otsuka · 1999
17. The load/deflection characteristics of thermally activated orthodontic archwires10.1093/ejo/25.4.417 ↗
18. Rotary-bending fatigue characteristics of medical-grade Nitinol wire10.1016/j.jmbbm.2013.06.003 ↗
19. Proffit · 2014
20. Measurement of friction forces between stainless steel wires and “reduced-friction” self-ligating brackets10.1016/j.ajodo.2008.07.025 ↗
21. A statistical approach to understand the role of inclusions on the fatigue resistance of superelastic Nitinol wire and tubing10.1016/j.jmbbm.2015.07.003 ↗
22. Singh · 2015
23. Resistance to sliding in orthodontics: a systematic review
24. Mechanical properties of a new thermoplastic polymer orthodontic archwire10.1016/j.msec.2014.05.008 ↗
25. The effect of crystallographic texture on stress-induced martensitic transformation in NiTi: a computational analysis10.1016/j.jmbbm.2015.08.023 ↗
26. Constant versus dissipating forces in orthodontics: the effect on initial tooth movement and root resorption10.1093/ejo/25.4.335 ↗
27. Influence of interbracket distances on the resistance to sliding of orthodontic appliances10.1016/j.ajodo.2006.04.032 ↗
28. Load-deflection characteristics of superelastic nickel-titanium orthodontic wires10.1067/mod.2002.121819 ↗