Reliable preparation of agarose phantoms for use in quantitative magnetic resonance elastography
Source abstract
Abstract
Agarose phantoms are one type of phantom commonly used in developing in vivo brain magnetic resonance elastography (MRE) sequences because they are inexpensive and easy to work with, store, and dispose of; however, protocols for creating agarose phantoms are non-standardized and often result in inconsistent phantoms with significant variability in mechanical properties. Many magnetic resonance imaging (MRI) and ultrasound studies use phantoms, but often these phantoms are not tailored for desired mechanical properties and as such are too stiff or not mechanically consistent enough to be used in MRE. In this work, we conducted a systematic study of agarose phantom creation parameters to identify those factors that are most conducive to producing mechanically consistent agarose phantoms for MRE research. We found that cooling rate and liquid temperature affected phantom homogeneity. Phantom stiffness is affected by agar concentration (quadratically), by final liquid temperature and salt content in phantoms, and by the interaction of these two metrics each with stir rate. We captured and quantified the implied relationships with a regression model that can be used to estimate stiffness of resulting phantoms. Additionally, we characterized repeatability, stability over time, impact on MR signal parameters, and differences in agar gel microstructure. This protocol and regression model should prove beneficial in future MRE development studies that use phantoms to determine stiffness measurement accuracy.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Ultrasound Imaging and Elastography · Ultrasound and Hyperthermia Applications · Elasticity and Material Modeling
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (56)
Show source-provided references
1. Observation of direction-dependent mechanical properties in the human brain with multi-excitation MR elastography10.1016/j.jmbbm.2016.03.005 ↗
2. Measuring the effects of aging and sex on regional brain stiffness with MR elastography in healthy older adults10.1016/j.neuroimage.2015.02.016 ↗
3. Travelling wave expansion: a model fitting approach to the inverse problem of elasticity reconstruction10.1109/TMI.2011.2131674 ↗
4. Nonlinear multiscale regularisation in MR elastography: towards fine feature mapping10.1016/j.media.2016.05.012 ↗
5. High-resolution mechanical imaging of the human brain by three-dimensional multifrequency magnetic resonance elastography at 7T10.1016/j.neuroimage.2013.12.032 ↗
6. Demonstration of concurrent tensile testing and magnetic resonance elastography10.1016/j.jmbbm.2016.06.020 ↗
7. Simultaneous magnetic resonance and optical elastography acquisitions: comparison of displacement images and shear modulus estimations using a single vibration source10.1016/j.jmbbm.2018.05.010 ↗
8. Mechanical characterization of human brain tissue10.1016/j.actbio.2016.10.036 ↗
9. Tuning acoustic and mechanical properties of materials for ultrasound phantoms and smart substrates for cell cultures10.1016/j.actbio.2016.11.049 ↗
10. Fifty years of brain tissue mechanical testing: from in vitro to in vivo investigations
11. Functional modification of agarose : a facile synthesis of an agarose-saccharate derivative10.1016/j.carbpol.2012.01.086 ↗
12. CIRS · 2008
13. Review of ultrasound elastography quality control and training test phantoms10.1258/ult.2011.011033 ↗
14. Characterization of a dielectric phantom for high-field magnetic resonance imaging applications10.1118/1.4895823 ↗
15. Mechanically tailored agarose hydrogels through molecular alloying with β-sheet polysaccharides10.1002/marc.201400353 ↗
16. MR elastography at 1 Hz of gelatin phantoms using 3D or 4D acquisition10.1016/j.jmr.2018.08.012 ↗
17. High-resolution magnetic resonance elastography reveals differences in subcortical gray matter viscoelasticity between young and healthy older adults10.1016/j.neurobiolaging.2018.01.010 ↗
18. Magnetic resonance elastography ( MRE ) of the human brain: technique, findings and clinical applications10.1088/0031-9155/61/24/R401 ↗
19. Curl-based finite element reconstruction of the shear modulus without assuming local homogeneity: time harmonic case10.1109/TMI.2013.2276060 ↗
20. Higher-resolution magnetic resonance elastography in meningiomas to determine intratumoral consistency10.1227/NEU.0000000000000892 ↗
21. Magnetic resonance elastography of the brain using multishot spiral readouts with self-navigated motion correction10.1002/mrm.24473 ↗
22. Viscoelasticity of subcortical gray matter structures10.1002/hbm.23314 ↗
23. Double dissociation of structure-function relationships in memory and fluid intelligence observed with magnetic resonance elastography10.1016/j.neuroimage.2018.01.007 ↗
24. Silicone breast phantoms for elastographic imaging evaluation10.1118/1.4805096 ↗
25. Review of tissue simulating phantoms with controllable optical, mechanical and structural properties for use in optical coherence tomography10.1364/BOE.3.001381 ↗
26. Feasibility of simultaneous temperature and tissue stiffness detection by MRE10.1002/mrm.20801 ↗
27. Characterization of a hyper-viscoelastic phantom mimicking biological soft tissue using an abdominal pneumatic driver with magnetic resonance elastography (MRE)10.1016/j.jbiomech.2012.01.017 ↗
28. Characterization of a hyper-viscoelastic phantom mimicking biological soft tissue using an abdominal pneumatic driver with Magnetic Resonance Elastography (MRE)10.1016/j.jbiomech.2012.01.017 ↗
29. Comparison of viscoelastic property characterization of plastisol phantoms with magnetic resonance elastography and high-frequency rheometry
30. Elastic properties of soft tissue-mimicking phantoms assessed by combined use of laser ultrasonics and low coherence interferometry10.1364/OE.19.010153 ↗
31. Magnetic resonance elastography: non-invasive mapping of tissue elasticity10.1016/S1361-8415(00)00039-6 ↗
32. Multiresolution MR elastography using nonlinear inversion10.1118/1.4754649 ↗
33. Use of a Rayleigh damping model in elastography10.1007/s11517-008-0356-5 ↗
34. Mechanical properties of the in vivo adolescent human brain10.1016/j.dcn.2018.06.001 ↗
35. Preoperative assessment of meningioma stiffness using magnetic resonance elastography10.3171/2012.9.JNS12519 ↗
36. Decreased brain stiffness in Alzheimer's disease determined by magnetic resonance elastography10.1002/jmri.22707 ↗
37. Regional brain stiffness changes across the Alzheimer's disease spectrum10.1016/j.nicl.2015.12.007 ↗
38. Artificial neural networks for stiffness estimation in magnetic resonance elastography10.1002/mrm.27019 ↗
39. Magnetic resonance elastography by direct visualization of propagating acoustic strain waves10.1126/science.7569924 ↗
40. New insight into agarose gel mechanical properties10.1021/bm005583j ↗
41. Spatially-resolved hydraulic conductivity estimation via poroelastic magnetic resonance elastography10.1109/TMI.2014.2311456 ↗
42. Visualization and quantification of breast cancer biomechanical properties with magnetic resonance elastography10.1088/0031-9155/45/6/314 ↗
43. Unravelling a direct role for polysaccharide β-strands in the higher order structure of physical hydrogels10.1002/anie.201701019 ↗
44. Structure-sensitive elastography: on the viscoelastic powerlaw behavior of in vivo human tissue in health and disease10.1039/c3sm50552a ↗
45. Magnetic resonance elastography of slow and fast shear waves illuminates differences in shear and tensile moduli in anisotropic tissue10.1016/j.jbiomech.2016.02.018 ↗
46. Medial temporal lobe viscoelasticity and relational memory performance10.1016/j.neuroimage.2016.02.059 ↗
47. Phantom evaluations of nonlinear inversion MR elastography10.1088/1361-6560/aacb08 ↗
48. Brain viscoelasticity alteration in chronic-progressive multiple sclerosis10.1371/journal.pone.0029888 ↗
49. Modification of agarose with carboxylation and grafting dopamine for promotion of its cell-adhesiveness10.1016/j.carbpol.2012.12.003 ↗
50. Independent tuning of acoustic and mechanical properties of phantoms for biomedical applications of ultrasound Independent tuning of acoustic and mechanical properties of phantoms for biomedical applications of ultrasound10.1088/2057-1976/aa5ed0 ↗
51. Three-dimensional subzone-based reconstruction algorithm for MR elastography10.1002/mrm.1111 ↗
52. Subzone based magnetic resonance elastography using a Rayleigh damped material model10.1118/1.3557469 ↗
53. MR-elastography reveals degradation of tissue integrity in multiple sclerosis10.1016/j.neuroimage.2009.06.018 ↗
54. Wideband MR elastography for viscoelasticity model identification10.1002/mrm.24495 ↗
55. Development of a phantom compatible for MRI and hyperthermia using carrageenan gel - relationship between T1and T2 values and NaCl concentration10.1080/0265673042000199268 ↗
56. Agarose-based biomaterials for tissue engineering10.1016/j.carbpol.2018.01.060 ↗