journal article·2020-02

A geometry optimization framework for transcatheter heart valve leaflet design

Mostafa Abbasi, Ali N. Azadani

Publisher page

Abstract

Transcatheter aortic valve replacement (TAVR) is an established treatment for patients with severe symptomatic aortic stenosis. It is known and recognized that leaflet geometry has a key role in structural and hemodynamic performance of bioprosthetic heart valves. Excessive mechanical stress on the leaflets will lead to accelerated tissue degeneration and diminished long-term valve durability. The goal of this study was to develop an automatic optimization framework by means of commercially available software packages to reduce maximum stress value of transcatheter aortic valve (TAV) leaflets. Leaflet design was parameterized by 2 s-order non-uniform rational B-splines (NURBS) curves and particle swarm optimization method was used to examine the optimization design space. Optimized leaflet geometry for 23-mm and 26-mm TAVs were obtained under dynamic physiological loading condition. Leaflet stress distributions of the optimized TAV geometries were compared with two commercially available bioprostheses (i) Carpentier-Edwards PERIMOUNT Magna surgical bioprosthesis and (ii) Edwards SAPIEN 3 transcatheter heart valve. A considerable reduction in the maximum in-plane principal stress was observed in the optimized TAV geometries compared to the commercially available bioprostheses. The optimization results underline the opportunity to improve leaflet design in the next generation of TAVs to potentially increase long-term durability of transcatheter heart valves.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Cardiac Valve Diseases and Treatments · Coronary Interventions and Diagnostics · Hydraulic and Pneumatic Systems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (34)

Show source-provided references
1. Leaflet stress and strain distributions following incomplete transcatheter aortic valve expansion10.1016/j.jbiomech.2015.08.012 ↗
2. Stress analysis of transcatheter aortic valve leaflets under dynamic loading: effect of reduced tissue thickness
3. Characterization of three-dimensional anisotropic heart valve tissue mechanical properties using inverse finite element analysis10.1016/j.jmbbm.2016.04.031 ↗
4. High resolution three-dimensional strain mapping of bioprosthetic heart valves using digital image correlation10.1016/j.jbiomech.2018.05.020 ↗
5. A non-invasive material characterization framework for bioprosthetic heart valves10.1007/s10439-018-02129-5 ↗
6. Transcatheter aortic-valve replacement with a self-expanding prosthesis10.1056/NEJMoa1400590 ↗
7. The effects of transcatheter valve crimping on pericardial leaflets10.1016/j.athoracsur.2013.11.009 ↗
8. Transcatheter aortic valve implantation in 2017: state of the art10.4244/EIJ-D-17-00567 ↗
9. First look at long-term durability of transcatheter heart valves: assessment of valve function up to 10 years after implantation
10. Structural changes in glutaraldehyde-treated porcine heterografts used as substitute cardiac valves. Transmission and scanning electron microscopic observations in 12 patients10.1016/0002-9149(78)90873-1 ↗
11. Dynamic and fluid–structure interaction simulations of bioprosthetic heart valves using parametric design with T-splines and Fung-type material models10.1007/s00466-015-1166-x ↗
12. Effect of geometry on the leaflet stresses in simulated models of congenital bicuspid aortic valves10.1007/s13239-011-0035-9 ↗
13. Effect of geometry on the leaflet stresses in simulated models of congenital bicuspid aortic valves10.1007/s13239-011-0035-9 ↗
14. Dynamic simulation pericardial bioprosthetic heart valve function10.1115/1.2244578 ↗
15. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery10.1056/NEJMoa1008232 ↗
16. Biologic determinants of dystrophic calcification and osteocalcin deposition in glutaraldehyde-preserved porcine aortic valve leaflets implanted subcutaneously in rats
17. Simulated thin pericardial bioprosthetic valve leaflet deformation under static pressure-only loading conditions: implications for percutaneous valves10.1007/s10439-010-0009-3 ↗
18. Simulated transcatheter aortic valve deformation: a parametric study on the impact of leaflet geometry on valve peak stress10.1002/cnm.2814 ↗
19. Transcatheter aortic-valve replacement with a balloon-expandable valve in low-risk patients10.1056/NEJMoa1814052 ↗
20. Particle swarm optimization (PSO). A tutorial10.1016/j.chemolab.2015.08.020 ↗
21. Comparison of transcatheter aortic valve and surgical bioprosthetic valve durability: a fatigue simulation study10.1016/j.jbiomech.2015.07.031 ↗
22. Transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients10.1056/NEJMoa1816885 ↗
23. Aortic bioprosthetic valve durability: incidence, mechanisms, predictors, and management of surgical and transcatheter valve degeneration10.1016/j.jacc.2017.07.715 ↗
24. The biomechanical effects of fatigue on the porcine bioprosthetic heart valve
25. Collagen fiber disruption occurs independent of calcification in clinically explanted bioprosthetic heart valves10.1002/jbm.10293 ↗
26. Tissue heart valves: current challenges and future research perspectives10.1002/(SICI)1097-4636(19991215)47:4<439::AID-JBM1>3.0.CO;2-O ↗
27. Onset and progression of experimental bioprosthetic heart valve calcification
28. Causes of failure and pathologic findings in surgically removed Ionescu-Shiley standard bovine pericardial heart valve bioprostheses: emphasis on progressive structural deterioration10.1161/01.CIR.76.3.618 ↗
29. Transcatheter versus surgical aortic-valve replacement in high-risk patients10.1056/NEJMoa1103510 ↗
30. Biomechanical behavior of bioprosthetic heart valve heterograft tissues: characterization, simulation, and performance10.1007/s13239-016-0276-8 ↗
31. The evolution of bioprosthetic heart valve design and its impact on durability10.1016/S1054-8807(03)00075-9 ↗
32. An anisotropic constitutive model for immersogeometric fluid–structure interaction analysis of bioprosthetic heart valves10.1016/j.jbiomech.2018.04.012 ↗
33. A framework for designing patient‐specific bioprosthetic heart valves using immersogeometric fluid–structure interaction analysis
34. Modeling the response of exogenously crosslinked tissue to cyclic loading: the effects of permanent set10.1016/j.jmbbm.2017.07.013 ↗