Investigating stress shielding spanned by biomimetic polymer-composite vs. metallic hip stem: A computational study using mechano-biochemical model
Source abstract
Abstract
Periprosthetic bone loss in response to total hip arthroplasty is a serious complication compromising patient's life quality as it may cause the premature failure of the implant. Stress shielding as a result of an uneven load sharing between the hip implant and the bone is a key factor leading to bone density decrease. A number of composite hip implants have been designed so far to improve load sharing characteristics. However, they have rarely been investigated from the bone remodeling point of view to predict a long-term response. This is the first study that employed a mechano-biochemical model, which considers the coupling effect between mechanical loading and bone biochemistry, to investigate bone remodeling after composite hip implantation. In this study, periprosthetic bone remodeling in the presence of Carbon fiber polyamide 12 (CF/PA12), CoCrMo and Ti alloy implants was predicted and compared. Our findings revealed that the most significant periprosthetic bone loss in response to metallic implants occurs in Gruen zone 7 (-43% with CoCrMo; -35% with Ti) and 6 (-40% with CoCrMo; -29% with Ti), while zone 4 has the lowest bone density decrease with all three implants (-9%). Also, the results showed that in terms of bone remodeling, the composite hip implant is more advantageous over the metallic ones as it provides a more uniform density change across the bone and induces less stress shielding which consequently results in a lower post-operative bone loss (-9% with CF/PA12 implant compared to -27% and -21% with CoCrMo and Ti alloy implants, respectively).
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (62)
Show source-provided references
1. Clinical and histologic results related to a low-modulus composite total hip replacement stem10.2106/JBJS.E.00316 ↗
2. Carbon fibre composite bone plates. Development, evaluation and early clinical experience10.1302/0301-620X.72B4.2380209 ↗
3. Biomechanical analysis of a new carbon fiber/flax/epoxy bone fracture plate shows less stress shielding compared to a standard clinical metal plate10.1115/1.4027669 ↗
4. Balle · 2004
5. Numerical investigations on the strain-adaptive bone remodelling in the periprosthetic femur: influence of the boundary conditions10.1186/1475-925X-8-7 ↗
6. The effect of muscle loading on the simulation of bone remodelling in the proximal femur10.1016/j.jbiomech.2004.03.005 ↗
7. Design of a biomimetic polymer-composite hip prosthesis10.1002/jbm.a.31146 ↗
8. Bone remodeling in a new biomimetic polymer-composite hip stem10.1002/jbm.a.32346 ↗
9. New predictive model for monitoring bone remodeling10.1002/jbm.a.32679 ↗
10. Long-term clinical consequences of stress-shielding after total hip arthroplasty without cement10.2106/00004623-199707000-00006 ↗
11. Callaghan · 2007
12. Mechanical Resuscitation of Chemical Oscillations in Belousov–Zhabotinsky Gels10.1002/adfm.201103036 ↗
13. Femoral osteolysis following total hip replacement10.1136/pgmj.2006.053215 ↗
14. Calcar unloading after hip replacement. A cadaver study of femoral stem designs10.3109/17453678709146448 ↗
15. Biomechanical properties of an intact, injured, repaired, and healed femur: an experimental and computational study10.1016/j.jmbbm.2012.09.005 ↗
16. Biomechanical comparison of implant retained fixed partial dentures with fiber reinforced composite versus conventional metal frameworks: a 3D FEA study10.1016/j.jmbbm.2010.09.011 ↗
17. Numerical optimization of the design of a coated, cementless hip prosthesis10.1007/BF00124881 ↗
18. Investigation of metallic and carbon fibre PEEK fracture fixation devices for three-part proximal humeral fractures10.1016/j.medengphy.2012.07.016 ↗
19. Frankel · 1980
20. Skeletal structural adaptations to mechanical usage (SATMU): 2. Redefining Wolff’s law: the remodeling problem10.1002/ar.1092260403 ↗
21. Performance study of braided carbon/PEEK composite compression bone plates10.1016/S0142-9612(03)00065-6 ↗
22. Modes of failures of cemented stem-type femoral components10.1097/00003086-197906000-00002 ↗
23. Wear and periprosthetic osteolysis: the problem10.1097/00003086-200112000-00007 ↗
24. Carbon fibre composites for orthopaedic implants10.1016/0010-4361(78)90345-2 ↗
25. Stiffness optimisation of cement and stem materials in total hip replacement
26. Mathematical relationships between bone density and mechanical properties: a literature review10.1016/j.clinbiomech.2007.08.024 ↗
27. The effect of variation in structure on the Young’s modulus of cancellous bone: a comparison of human and non-human material10.1243/PIME_PROC_1990_204_240_02 ↗
28. Population-based reference values for bone mineral density in young men10.1007/s00198-007-0399-8 ↗
29. Stress shielding and bone resorption in THA: clinical versus computer-simulation studies
30. The relationship between stress shielding and bone resorption around total hip stem and the effects of flexible materials10.1097/00003086-199201000-00014 ↗
31. Material optimization of femoral component of total hip prosthesis using fiber reinforced polymeric composites10.1016/S1350-4533(01)00079-0 ↗
32. Dual-energy X-ray absorptiometry measurement of bone mineral density around porous-coated cementless femoral implants. Methods and preliminary results10.1302/0301-620X.75B2.8444950 ↗
33. A thermodynamic model of bone remodelling: the influence of dynamic loading together with biochemical control
34. A coupled mechano-biochemical model for bone adaptation
35. Evaluation of periprosthetic bone using dual-energy x-ray absorptiometry: precision of the method and effect of operation on bone mineral density10.1002/jbmr.5650111020 ↗
36. Bone density at the proximal femur after total hip arthroplasty
37. Computational modeling of hip replacement surgery: total hip replacement vs hip resurfacing
38. Bone remodeling after total hip arthroplasty with a short stemmed metaphyseal loading implant: finite element analysis validated by a prospective DEXA investigation10.1002/jor.22120 ↗
39. An energy dissipation-based model for damage stimulated bone adaptation10.1016/S0021-9290(98)00039-6 ↗
40. The influence of prosthetic stem stiffness and of a calcar collar on stresses in the proximal end of the femur with a cemented femoral component10.2106/00004623-198466020-00016 ↗
41. Failure analysis of composite femoral components for hip arthroplasty10.1682/JRRD.2003.03.0133 ↗
42. Periprosthetic changes in bone mineral density in 5 stem designs 5 years after cemented total hip arthroplasty, no relation to stem migration10.1016/j.arth.2006.05.035 ↗
43. Design of composite hip prostheses considering the long-term behavior of the femur
44. Effect of stem modulus in a total hip arthroplasty model10.1302/0301-620X.73B1.1991773 ↗
45. A composite hip implant
46. Kinetik der invertinwirkung
47. Bone loss from the proximal femur after arthroplasty with an isoelastic femoral stem. BMD measurements in 25 patients after 9 years10.3109/17453679508995559 ↗
48. Prediction of bone adaptation using damage accumulation10.1016/0021-9290(94)90223-2 ↗
49. Late instability following total hip arthroplasty10.3121/cmr.2007.717 ↗
50. Modeling bone resorption using mixture theory with chemical reactions10.2140/jomms.2007.2.1141 ↗
51. Biomechanical assessment of composite versus metallic intramedullary nailing system in femoral shaft fractures: a finite element study10.1016/j.clinbiomech.2014.05.010 ↗
52. Shanbhag · 2006
53. Periprosthetic proximal bone loss after uncemented hip arthroplasty is related to stem size: DXA measurements in 138 patients followed for 2–7 years10.1080/17453670610046307 ↗
54. Optimal design of customised hip prosthesis using fiber reinforced polymer composites10.1016/j.matdes.2010.01.016 ↗
55. Bone remodelling around a cementless straight THA stem: a prospective dual-energy X-ray absorptiometry study10.5301/HIP.2012.9227 ↗
56. Predicting bone remodeling in response to total hip arthroplasty: computational study using mechanobiochemical model10.1115/1.4026642 ↗
57. Differential gene expression of bone anabolic factors and trabecular bone architectural changes in the proximal femoral shaft of primary hip osteoarthritis patients10.1186/ar2101 ↗
58. Computational bone remodelling simulations and comparisons with DEXA results10.1016/j.orthres.2005.02.002 ↗
59. The behavior of adaptive bone-remodeling simulation models10.1016/0021-9290(92)90056-7 ↗
60. Wolff · 1892 · 1986
61. Potential application of graphite fiber and methyl methacrylate resin composites as internal fixation plates10.1002/jbm.820080513 ↗
62. Evaluation of periprosthetic bone-remodeling after cementless total hip arthroplasty. The influence of the extent of porous coating10.2106/00004623-200010000-00009 ↗