journal article·2018-09Open access

Cervical fusion cage computationally optimized with porous architected Titanium for minimized subsidence

Ahmed Moussa, Michael Tanzer, Damiano Pasini

Abstract

Anterior cervical discectomy with fusion is a common surgical treatment that can relieve patients suffering from cervical spondylosis. This surgery is most commonly performed with the use of a cervical cage. One serious complication of the fusion cages commercially available in the market is subsidence of the cage with loss of the normal alignment of the spine and recurrent pain. This work presents the proof-of-concept of a fusion cage made of a graded porous titanium with microarchitecture minimizing the risk of subsidence associated with fully-solid implants. The optimized properties of the porous implant are obtained through a scheme combining multiscale mechanics and density-based topology optimization. Asymptotic homogenization is used to capture the effective properties of the porous material, which uses a tetrahedron based cell as building block. The stress levels and normal strains obtained under various loading conditions on the C7 superior surface of the vertebrae are used as indicators of subsidence. The results suggest a reduced risk of subsidence for the optimized implant versus the fully-solid implant. Under the most severe condition of combined loading, a collective improvement of the average von Mises stress up to 14% can be observed on the posterior, left, and right lateral regions of the C7 superior surface. Similarly, for the average normal strain, the optimized cage exhibits a more favourable distribution with a top gain of 21.7% at given locations.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced Mathematical Modeling in Engineering · Composite Material Mechanics · Topology Optimization in Engineering

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (71)

Show source-provided references
1. Intervertebral disc arthroplasty10.1097/01.brs.0000146460.11591.8a ↗
2. Cervical spine bone mineral density as a function of vertebral level and anatomic location10.1016/j.spinee.2011.05.007 ↗
3. Mechanical properties of lattice materials via asymptotic homogenization and comparison with alternative homogenization methods10.1016/j.ijmecsci.2013.10.003 ↗
4. High-strength porous biomaterials for bone replacement: a strategy to assess the interplay between cell morphology, mechanical properties, bone ingrowth and manufacturing constraints10.1016/j.actbio.2015.10.048 ↗
5. Fully porous 3D printed titanium femoral stem to reduce stress-shielding following total hip arthroplasty10.1002/jor.23445 ↗
6. Multiscale design and Multiobjective optimization of orthopedic hip implants with functionally graded cellular material10.1115/1.4006115 ↗
7. Fatigue design of a mechanically biocompatible lattice for a proof-of-concept femoral stem10.1016/j.jmbbm.2013.03.002 ↗
8. Subsidence of stand-alone cervical carbon fiber cages
9. Bendsøe · 1995
10. Topology optimization: theory
11. The treatment of disabling single-level lumbar discogenic low back pain with total disc arthroplasty utilizing the Prodisc prosthesis: a prospective study with 2-year minimum follow-up10.1097/01.brs.0000182217.87660.40 ↗
12. Anterior cervical discectomy and fusion: comparison of titanium and polyetheretherketone cages10.1186/1471-2474-13-172 ↗
13. Bone graft substitutes in anterior cervical discectomy and fusion10.1007/s00586-008-0878-4 ↗
14. Finite element analysis of Cage subsidence in cervical interbody fusion
15. The design evolution of interbody cages in anterior cervical discectomy and fusion: a systematic review10.1186/s12891-015-0546-x ↗
16. Titanium/Polyetheretherketone cages for cervical arthrodesis with degenerative and traumatic pathologies: early clinical outcomes and fusion rates10.1111/os.12221 ↗
17. Efficacy of anterior cervical fusion: comparison of titanium cages, polyetheretherketone (PEEK) cages and autogenous bone grafts10.1016/j.jocn.2007.05.016 ↗
18. Cignoni, P., Corsini, M.C.M., Dellepiane, M., Ganovelli, F., Ranzuglia, G., 2008. MeshLab: an Open-Source Mesh Processing Tool. Proceedings of the Sixth Eurographics Italian Chapter Conference: p. 129-136.
19. Finite element models predict in vitro vertebral body compressive strength better than quantitative computed tomography10.1016/S8756-3282(03)00210-2 ↗
20. Effective properties of the octet-truss lattice material10.1016/S0022-5096(01)00010-2 ↗
21. Anterior cervical discectomy and fusion associated complications10.1097/BRS.0b013e318154c57e ↗
22. Effect of design and implantation technique on risk of progressive sintering of various cervical vertebrae cages
23. Subsidence of stand-alone cervical cages in anterior interbody fusion: warning
24. Prediction of load sharing among spinal components of a C5-C6 motion segment using the finite element approach10.1097/00007632-199803150-00008 ↗
25. Preprocessing and postprocessing for materials based on the homogenization method with adaptive finite element methods10.1016/0045-7825(90)90148-F ↗
26. A direct method to derive the boundary conditions of the homogenization equation for symmetric cells10.1002/(SICI)1099-0887(199603)12:3<185::AID-CNM970>3.0.CO;2-2 ↗
27. Hassani, B.H., 1997. E., a review of homogenization and topology optimization I-homogenization theory for media with periodic structure.10.1016/S0045-7949(98)00131-X ↗
28. Cellular Ti–6Al–4V structures with interconnected macro porosity for bone implants fabricated by selective electron beam melting10.1016/j.actbio.2008.03.013 ↗
29. A comparison of homogenization and standard mechanics analyses for periodic porous composites10.1007/BF00369853 ↗
30. The finite element method: linear static and Dynamic finite element analysis: Thomas J. R. Hughes10.1111/j.1467-8667.1989.tb00025.x ↗
31. Prevalence of cervical spondylosis in a general practice10.1016/S0140-6736(65)92674-7 ↗
32. Effects of neck movements on stability and subsidence in cervical interbody fusion: an in vitro study
33. Engineered tissue scaffolds with variational porous architecture10.1115/1.4002933 ↗
34. Quantitative computed tomography estimates of the mechanical properties of human vertebral trabecular bone10.1016/S0736-0266(01)00185-1 ↗
35. Does partial coating with titanium improve the radiographic fusion rate of empty PEEK cages in cervical spine surgery? A comparative analysis of clinical data10.1186/s13037-017-0127-z ↗
36. PEEK biomaterials in trauma, orthopedic, and spinal implants10.1016/j.biomaterials.2007.07.013 ↗
37. Comparison of geometry-based and CT voxel-based finite element modelling and experimental validation10.1016/S1350-4533(98)00054-X ↗
38. Polyetheretherketone (PEEK) cage filled with cancellous allograft in anterior cervical discectomy and fusion10.1007/s00264-007-0378-x ↗
39. Interbody fusion cage design using integrated global layout and local microstructure topology optimization10.1097/01.BRS.0000134573.14150.1A ↗
40. Stress analysis of the interface between cervical vertebrae end plates and the bryan, prestige LP, and ProDisc-C cervical disc prostheses: an in vivo image-based finite element study10.1097/BRS.0b013e3181aa643b ↗
41. A prospective randomized comparison of coralline hydroxyapatite with autograft in cervical interbody fusion10.1097/01.BRS.0000048503.51956.E1 ↗
42. Mechanical characterization of structurally porous biomaterials built via additive manufacturing: experiments, predictive models, and design maps for load-bearing bone replacement implants10.1016/j.actbio.2017.09.013 ↗
43. Load-displacement properties of lower cervical spine motion segments10.1016/0021-9290(88)90285-0 ↗
44. Biomechanical competence of vertebral trabecular bone in relation to ash density and age in normal individuals10.1016/8756-3282(87)90074-3 ↗
45. Next-generation biomedical implants using additive manufacturing of complex, cellular and functional mesh arrays10.1098/rsta.2010.0010 ↗
46. Multi-scale finite element analysis of porous materials and components by asymptotic homogenization theory and enhanced mesh superposition method10.1088/0965-0393/11/2/303 ↗
47. Outcomes of interbody fusion cages used in 1 and 2-levels anterior cervical discectomy and fusion: titanium cages versus polyetheretherketone (PEEK) cages10.1097/BSD.0b013e3181af3a84 ↗
48. Three-dimensional methods for quantification of cancellous bone architecture10.1016/S8756-3282(97)00007-0 ↗
49. Anterior cervical discectomy and fusion using a stand-alone polyetheretherketone cage packed with local Autobone: assessment of bone fusion and subsidence10.3340/jkns.2013.54.3.189 ↗
50. Carbon fiber debris within the synovial joint. A time-dependent mechanical and histologic study10.1097/00003086-198506000-00011 ↗
51. Mechanical evaluation of porous titanium (Ti6Al4V) structures with electron beam melting (EBM)10.1016/j.jmbbm.2009.10.006 ↗
52. Comparison of isotropic and orthotropic material property assignments on femoral finite element models under two loading conditions10.1016/j.medengphy.2005.06.003 ↗
53. Spine interbody implants: material selection and modification, functionalization and bioactivation of surfaces to improve osseointegration10.1111/os.12098 ↗
54. Relations of mechanical properties to density and CT numbers in human bone10.1016/1350-4533(95)97314-F ↗
55. A prospective randomized study comparing a cervical carbon fiber cage to the Smith–Robinson technique with allograft and plating: up to 24 months follow-up10.1007/s00586-005-0951-1 ↗
56. Sigmund · 1994
57. On the design of compliant mechanisms using topology optimization10.1080/08905459708945415 ↗
58. Morphology-based black and white filters for topology optimization10.1007/s00158-006-0087-x ↗
59. Numerical instabilities in topology optimization: a survey on procedures dealing with checkerboards, mesh-dependencies and local minima10.1007/BF01214002 ↗
60. The treatment of certain cervical-spine disorders by anterior removal of the intervertebral disc and interbody fusion10.2106/00004623-195840030-00009 ↗
61. Three-dimensional plotted scaffolds with controlled pore size gradients: effect of scaffold geometry on mechanical performance and cell seeding efficiency10.1016/j.actbio.2010.11.003 ↗
62. Morphometric and mechanical evaluation of titanium implant integration: comparison of five surface structures10.1002/(SICI)1097-4636(200007)51:1<15::AID-JBM3>3.0.CO;2-9 ↗
63. A general theory of strength for anisotropic materials10.1177/002199837100500106 ↗
64. The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone10.1016/S8756-3282(99)00098-8 ↗
65. A comparative study on different methods of automatic mesh generation of human femurs10.1016/S1350-4533(97)00049-0 ↗
66. Operative treatment of the degenerated segment adjacent to a lumbar fusion10.1097/00007632-199403000-00007 ↗
67. Bone regeneration by the osteoconductivity of porous titanium implants manufactured by selective laser melting: a histological and micro computed tomography study in the rabbit10.1089/ten.tea.2012.0753 ↗
68. Primary stabilizing effect of interbody fusion devices for the cervical spine: an in vitro comparison between three different cage types and bone cement10.1007/s005860000168 ↗
69. Wilke · Subsid. Resulting Simula. Postoper. Neck Mov.: Vitr. Investig. a New Cerv. Fusion Cage · 2000 · 25 · 2762
70. Yang, King-Hay, Basic finite element method as applied to injury biomechanics, 2017.
71. User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability10.1016/j.neuroimage.2006.01.015 ↗