Influence of femoral stem surface finish on the apparent static shear strength at the stem–cement interface
Source abstract
Abstract
The stem-cement interface has long been implicated in failure of cemented total hip replacement. Much research has been performed to study the factors affecting the bond strength between the femoral stem and the bone cement. The present study aims to further investigate the influence of femoral stem surface finish on the apparent static shear strength at the stem-cement interface through a series of pull out tests, where stainless steel rods are employed to represent the femoral stem. The results demonstrated that there was a general tendency for the apparent static shear strength to be increased with the rise of surface roughness. The polished and glass bead-blasted rods illustrated a slip-stick-slip failure whereas the shot-blasted and grit-blasted rods displayed gross interface failure. Following pull out test, cement transfer films were detected on the polished rods, and there was cement debris adhered to the surface of the grit-blasted rods. Micropores, typically 120 mum in diameter, were prevalent in the cement surface interfaced with the polished rods, and the cement surfaces in contact with the shot-blasted and grit-blasted rods were greatly damaged. There was also evidence of metal debris embedding within the cement mantle originating from the tests of the grit-blasted rods, indicating an extremely strong mechanical interlocking at the interface. In summary, this present research demonstrated that the grit-blasted rods with the highest surface roughness were the best in terms of apparent static shear strength. However, it seemed to be most applicable only to the stem designs in which mechanical interlocking of the stem in the initial fixed position was essential.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. Should total hip arthroplasty femoral components be designed to subside? A radiostereometric analysis study of the Charnley Elite and Exeter stems10.1054/arth.2001.23576 ↗
2. Brown, L., 2006. The use of 3D surface analysis techniques to investigate the wear of matt surface finish femoral stems in total hip replacement. Ph.D. Thesis, University of Huddersfield, Huddersfield
3. The effect of surface preparation on metal-bone cement interfacial strength10.1002/jbm.820210607 ↗
4. Anchorage of the femoral head prosthesis to the shaft of the femur10.1302/0301-620X.42B1.28 ↗
5. Fatigue model to characterize cement-metal interface in dynamic shear10.1097/00003086-199805000-00031 ↗
6. Effect of metal surface topography on mechanical bonding at simulated total hip stem–cement interfaces10.1002/(SICI)1097-4636(1999)48:4<440::AID-JBM7>3.0.CO;2-5 ↗
7. Cemented femoral component surface finish mechanics10.1097/00003086-199810000-00010 ↗
8. Fracture and loosening of Charnley femoral stems: Comparison between first-generation and subsequent designs10.1302/0301-620X.75B2.8444947 ↗
9. Improvement of the long-term adhesive strength between metal stem and polymethylmethacrylate bone cement by a silica/silane interlayer system10.1002/1097-4636(20011205)57:3<413::AID-JBM1184>3.0.CO;2-R ↗
10. The clinical significance of vacuum mixing bone cement10.1097/00003086-200101000-00034 ↗
11. Loosening of matt and polished cemented femoral stems10.1302/0301-620X.80B4.0800573 ↗
12. Hull · 1981
13. Hustosky, K.T., Norman, T.L., Kish, V.L., Gruen, T.A., Blaha, J.D., 1999. The effect of surface finish on the behaviour of tapered cemented total hip stems. In: The 23rd Annu. Mtg. Am. Soc. Biomech., Pennsylvania, October 21–23
14. Hutchings · 1992
15. The initiation of failure in cemented femoral components of hip arthroplasties10.1302/0301-620X.73B4.2071634 ↗
16. Factors affecting surgical alloy/bone cement interface adhesion10.1002/jbm.820140510 ↗
17. The relationship between cement fatigue damage and implant surface finish in proximal femoral prostheses10.1016/S1350-4533(03)00120-6 ↗
18. Analysis of long-term cemented total hip arthroplasty retrievals10.1097/00003086-200212000-00009 ↗
19. Mechanical characteristics of the stem–cement interface10.1002/jor.1100090605 ↗
20. Enhanced strength in cemented stem fixation using adhesive acrylic cement as a metal coating material10.1002/(SICI)1097-4636(199702)34:2<171::AID-JBM5>3.0.CO;2-N ↗
21. The effect of improved cementing techniques on component loosening in total hip replacement10.1302/0301-620X.72B5.2211749 ↗
22. Adhesion and reliability of interfaces in cemented total joint arthroplasties10.1002/jor.1100160612 ↗
23. Femoral stem fixation: An engineering interpretation of the long term outcome of Charnley and Exeter stems10.1302/0301-620X.80B5.0800754 ↗
24. Some factors affecting the strength of the cement-metal interface10.1302/0301-620X.71B2.2925738 ↗
25. A prospective randomized trial of cemented femoral components with polished versus grit-blasted surface finish and identical stem geometry10.1016/S0883-5403(03)00298-5 ↗
26. The effect of cement-stem debonding in THA on the long-term failure probability of cement10.1016/S0021-9290(97)00038-9 ↗
27. Factors affecting the static shear strength of the prosthetic stem-bone cement interface10.1023/A:1021501520479 ↗