A finite element study on the mechanical response of the head-neck interface of hip implants under realistic forces and moments of daily activities: Part 1, level walking
Source abstract
Abstract
This paper investigates the mechanical response of a modular head-neck interface of hip joint implants under realistic loads of level walking. The realistic loads of the walking activity consist of three dimensional gait forces and the associated frictional moments. These forces and moments were extracted for a 32mm metal-on-metal bearing couple. A previously reported geometry of a modular CoCr/CoCr head-neck interface with a proximal contact was used for this investigation. An explicit finite element analysis was performed to investigate the interface mechanical responses. To study the level of contribution and also the effect of superposition of the load components, three different scenarios of loading were studied: gait forces only, frictional moments only, and combined gait forces and frictional moments. Stress field, micro-motions, shear stresses and fretting work at the contacting nodes of the interface were analysed. Gait forces only were found to significantly influence the mechanical environment of the head-neck interface by temporarily extending the contacting area (8.43% of initially non-contacting surface nodes temporarily came into contact), and therefore changing the stress field and resultant micro-motions during the gait cycle. The frictional moments only did not cause considerable changes in the mechanical response of the interface (only 0.27% of the non-contacting surface nodes temporarily came into contact). However, when superposed with the gait forces, the mechanical response of the interface, particularly micro-motions and fretting work, changed compared to the forces only case. The normal contact stresses and micro-motions obtained from this realistic load-controlled study were typically in the range of 0-275MPa and 0-38µm, respectively. These ranges were found comparable to previous experimental displacement-controlled pin/cylinder-on-disk fretting corrosion studies.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Titanium Alloys Microstructure and Properties · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (38)
Show source-provided references
1. Realistic loads for testing hip implants10.3233/BME-2010-0616 ↗
2. Hip joint loading during walking and running, measured in two patients10.1016/0021-9290(93)90058-M ↗
3. Fretting fatigue and fretting wear10.1016/0301-679X(89)90081-9 ↗
4. Friction moments of large metal-on-metal hip joint bearings and other modern designs10.1016/j.medengphy.2008.01.001 ↗
5. High failure rates with a large-diameter hybrid metal-on-metal total hip replacement: clinical, radiological and retrieval analysis10.1302/0301-620X.93B5.26309 ↗
6. Bronzino · 2006
7. Bryant, M., 2013. Fretting-crevice corrosion of cemented metal on metal total hip replacements. In: School of Mechanical Engineering., The University of Leeds.
8. Characterisation of the surface topography, tomography and chemistry of fretting corrosion product found on retrieved polished femoral stems10.1016/j.jmbbm.2013.11.016 ↗
9. Pseudotumour formation due to tribocorrosion at the taper interface of large diameter metal on polymer modular total hip replacements10.1016/j.arth.2013.02.009 ↗
10. Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty10.2106/JBJS.K.01352 ↗
11. Friction in total hip joint prosthesis measured in vivo during walking10.1371/journal.pone.0078373 ↗
12. In vivo measured joint friction in hip implants during walking after a short rest10.1371/journal.pone.0174788 ↗
13. Total hip arthroplasty head–neck contact mechanics: a stochastic investigation of key parameters10.1016/j.jbiomech.2014.02.035 ↗
14. Finite element analysis of the head–neck taper interface of modular hip prostheses10.1016/j.triboint.2015.01.016 ↗
15. A computational approach to fretting wear prediction at the head–stem taper junction of total hip replacements10.1016/j.wear.2015.06.016 ↗
16. In vivo records of hip loads using a femoral implant with telemetric output (a prelimary report)10.1016/0141-5425(79)90066-9 ↗
17. Influence of geometry and materials on the axial and torsional strength of the head–neck taper junction in modular hip replacements: a finite element study10.1016/j.jmbbm.2015.12.044 ↗
18. A novel analytical approach for determining the frictional moments and torques acting on modular femoral components in total hip replacements10.1016/j.jbiomech.2015.02.010 ↗
19. An analytical calculation of frictional and bending moments at the head-neck interface of hip joint implants during different physiological activities10.3390/ma9120982 ↗
20. In vitro friction and lubrication of large bearing hip prostheses10.1243/09544119JEIM733 ↗
21. Fretting crevice corrosion of stainless steel stem–CoCr femoral head connections: comparisons of materials, initial moisture, and offset length10.1002/jbm.b.31164 ↗
22. In vitro corrosion testing of modular hip tapers10.1002/jbm.b.10526 ↗
23. Circulating levels of cobalt and chromium from metal-on-metal hip replacement are associated with CD8+ T-cell lymphopenia10.1302/0301-620X.91B6.21844 ↗
24. The chemical form of metallic debris in tissues surrounding metal-on-metal hips with unexplained failure10.1016/j.actbio.2010.06.006 ↗
25. Is increased modularity associated with increased fretting and corrosion damage in metal-on-metal total hip arthroplasty devices?: a retrieval study10.1016/j.arth.2013.05.040 ↗
26. Is increased modularity associated with increased fretting and corrosion damage in metal-On-metal total hip arthroplasty devices?: a retrieval study10.1016/j.arth.2013.05.040 ↗
27. Presence of corrosion products and hypersensitivity-associated reactions in periprosthetic tissue after aseptic loosening of total hip replacements with metal bearing surfaces10.1016/j.actbio.2008.07.032 ↗
28. Head-neck taper corrosion in hip arthroplasty10.1155/2015/758123 ↗
29. Micro-motions at the stem-head taper of modular hip prostheses during daily living activities
30. Low torque levels can initiate a removal of the passivation layer and cause fretting in modular hip stems10.1016/j.medengphy.2014.06.011 ↗
31. Metallosis after contemporary metal-on-metal total hip arthroplasty: five to nine-year follow-up10.2106/00004623-200606000-00003 ↗
32. Instructional review: hip modular neck femoral stems10.1302/0301-620X.95B8.31525 ↗
33. Do ceramic femoral heads reduce taper fretting corrosion in hip arthroplasty? A retrieval study10.1007/s11999-013-3096-2 ↗
34. Surface modification of titanium, titanium alloys, and related materials for biomedical applications10.1016/j.mser.2004.11.001 ↗
35. Progress in standardization of fretting fatigue terminology and testing10.1016/j.triboint.2010.12.001 ↗
36. The effect of frictional torque and bending moment on corrosion at the taper interface: an in vitro study10.1302/0301-620X.97B4.34800 ↗
37. Influence of assembly procedure and material combination on the strength of the taper connection at the head–neck junction of modular hip endoprostheses10.1016/j.clinbiomech.2011.08.002 ↗
38. Fretting corrosion of CoCrMo and Ti6Al4V interfaces10.1016/j.biomaterials.2012.04.015 ↗