journal article·2017-04

A new approach to improve the local compressive properties of PPDO self-expandable stent

Fan Zhao, Wen Xue, Fujun Wang, Chenglong Yu, Haiyan Xu, Yi Hao, Lu Wang

Publisher page

Abstract

The radial performance of bioabsorbable polymeric intravascular stents is extremely important in assessing the efficiency of these devices in expanding narrow lumen, reducing stent recoil, and recovering to their original states after suffering from pulsating pressure. However, these stents remain inferior to metallic stents. Several thermal treatment conditions (60°C, 80°C, and 100°C for 1h) were investigated to improve the characteristics of poly(p-dioxanone) (PPDO) self-expandable stents. The local compressive force, stiffness, and viscoelasticity of these stents were also evaluated. Wide-angle X-ray diffraction and different scanning calorimetry measurements were performed to evaluate the recrystalline and thermodynamic changes of molecular chains. The declining conformer entropy of PPDO monofilaments was examined via energy analysis. The untreated stents had compressive modules of 514.80±70.59mN/mm, which was much higher than those of 80°C and 100°C treated stents (332.35±66.08mN/mm and 394.31±64.71mN/mm, respectively). Nevertheless, 100°C annealing stents had less stress relaxation and prior elastic recovery rate of 82.32±3.43mN and 92.55±1.61%, respectively, showing a much better shape stability than untreated stents (139.51±16.67mN and 86.18±3.57%, respectively). These findings present important clinical implications in the stent manufacturing process and warrant further study to develop new bioabsorbable stents with outstanding clinical efficacy.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Coronary Interventions and Diagnostics · Orthopaedic implants and arthroplasty · Electrospun Nanofibers in Biomedical Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (52)

Show source-provided references
1. Carotid artery stenting using a novel self-expanding braided nickel-titanium stent: feasibility and safety porcine trial10.1007/s00270-009-9572-0 ↗
2. Mechanical behavior and in vivo properties of newly designed bare metal stent for enhanced flexibility10.1016/j.jiec.2014.05.045 ↗
3. Miscibility, thermal and mechanical properties of Poly(para-dioxanone)/Poly(lactic-co-glycolic acid) blends10.1007/s10924-014-0686-3 ↗
4. Elastic recoil of coronary stents: a comparative analysis
5. Effect of stent radial force on stress pattern after deployment: a finite element study10.1007/s11665-014-0913-z ↗
6. Effect of heat treatment on the thermal and mechanical properties of a precursor polymer: polyhydroxyamide10.1016/S0032-3861(97)10364-0 ↗
7. Quantitative physical and handling characteristics of novel antibacterial braided silk suture materials10.1016/j.jmbbm.2015.06.013 ↗
8. Antibacterial surgical silk sutures using a high-performance slow-release carrier coating system10.1021/acsami.5b06239 ↗
9. Contribution of hemispheric CaCO3 to improving crystalline, physical properties and biocompatibility of Poly(p-dioxanone)10.1021/acs.iecr.5b00796 ↗
10. The effect of strain rate on the viscoplastic behavior of isotactic polypropylene at finite strains10.1016/S0032-3861(02)00853-4 ↗
11. An overview of superelastic stent design10.1080/13645700009169654 ↗
12. Changes in structural and mechanical behaviour of PVDF with processing or thermal treatment. 2. Evolution of mechanical behaviour10.1016/S0032-3861(01)00184-7 ↗
13. Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective, non-randomised multicentre trial10.1016/S0140-6736(07)60853-8 ↗
14. A link between stent radial forces and vascular wall remodeling: the discovery of an optimal stent radial force for minimal vessel restenosis.10.3109/03008200903329771 ↗
15. X-Ray and electron diffraction study of Poly(p-dioxanone)10.1002/marc.200400399 ↗
16. A novel, ring-connected stent versus conventional GI stents: comparative study of physical properties and migration rates in a canine colon obstruction model10.1016/j.gie.2014.09.040 ↗
17. Heat capacity of poly-p-dioxanone10.1080/00222349808220453 ↗
18. Remodeling of human coronary arteries undergoing coronary angioplasty or atherectomy10.1161/01.CIR.96.2.475 ↗
19. Three-year follow-up after implantation of metallic coronary-artery stents10.1056/NEJM199602293340903 ↗
20. Medical fibers and biotextiles10.1016/B978-0-08-087780-8.00029-2 ↗
21. Approaches for prevention of restenosis10.1002/jbm.b.30974 ↗
22. Study of heat-setting treatment for biomedical polydioxanone stents
23. Li, G., Li, Y., Lan, P., Hu, J.Y., He, X.W., Li, J.S., 2014a. Heat-setting Effects on Physical and Mechanical Properties of Prototyped Biodegradable Stents, in: Li, Y., Xin, J.H., Yoon, K.J., Li, J.S. (Eds.), Textile Bioengineering and Informatics Symposium Proceedings, 2014, Vols 1 and 2. pp. 145–151.
24. Biodegradable weft- knitted intestinal stents: fabrication and physical changes investigation in vitro degradation10.1002/jbm.a.34759 ↗
25. Coronary stents: a materials perspective10.1016/j.biomaterials.2006.11.042 ↗
26. An experimental evaluation of device/arterial wall compliance mismatch for four stent-graft devices and a multi-layer flow modulator device for the treatment of abdominal aortic aneurysms10.1016/j.ejvs.2015.07.041 ↗
27. Biodegradable polymers as biomaterials10.1016/j.progpolymsci.2007.05.017 ↗
28. Bioresorbable scaffold the advent of a new era in percutaneous coronary and peripheral revascularization?10.1161/CIRCULATIONAHA.110.971606 ↗
29. Onuma, Y., Serruys, P.W., Muramatsu, T., Nakatani, S., van Geuns, R.J., de Bruyne, B., Dudek, D., Christiansen, E., Smits, P.C., Chevalier, B., McClean, D., Koolen, J., Windecker, S., Whitbourn, R., Meredith, I., Garcia-Garcia, H.M., Veldhof, S., Rapoza, R., Ormiston, J.A., 2014. Incidence and Imaging Outcomes of Acute Scaffold Disruption and Late Structural Discontinuity After Implantation of the Absorb Everolimus-Eluting Fully Bioresorbable Vascular Scaffold Optical Coherence Tomography Assessment in the ABSORB Cohort B Trial (A. Jacc-Cardiovascular Interv. 7, 1400–1411.10.1016/j.jcin.2014.06.016 ↗
30. Bioabsorbable coronary stents10.1161/CIRCINTERVENTIONS.109.859173 ↗
31. Late regression of the dilated lesion after coronary angioplasty: a 5 year quantitative angiographic study10.1016/S0735-1097(96)82489-2 ↗
32. Elastic recoil of coronary stents: a comparative analysis
33. Melt behaviour, crystallinity and morphology of poly(p-dioxanone)10.1016/S0032-3861(01)00273-7 ↗
34. On the thermomechanics of materials that have multiple natural configurations - Part I: viscoelasticity and classical plasticity10.1007/s00033-004-4019-6 ↗
35. Influence of design parameters on the mechanical behavior and porosity of braided fibrous stents10.1016/j.matdes.2015.07.051 ↗
36. Radial force of coronary stents: a comparative analysis. Catheter10.1002/(SICI)1522-726X(199903)46:3<380::AID-CCD27>3.0.CO;2-J ↗
37. Rubinstein · 2003
38. Crystallisation and morphology of neat and degraded poly(p-dioxanone)10.1016/S0141-3910(01)00126-4 ↗
39. Safian · 2001
40. Evaluation of the late stent recoil of first and second generation drug-eluting stents
41. Standards, I., n.d. Cardiovascular Implants - Endovascular Devices - Part 2: Vascular Stents.
42. Standards, S., n.d. Cardiovascular Implants - Endovascular Devices - Part 2: Vascular Stents (Iso 25539-2:2012).
43. Properties and morphologies of poly(L-lactide). 1. Annealing condition effects on properties and morphologies of poly(L-lactide)10.1016/0032-3861(95)93647-5 ↗
44. Neointima formation following arterial placement of self-expanding stents of different radial force - experimental results10.1007/BF01102068 ↗
45. In vitro degradation behaviours of PDO monofilament and its intravascular stents with braided structure10.1515/aut-2015-0031 ↗
46. The influence of thermal treatment on the mechanical characteristics of a PLLA coiled stent10.1002/jbm.b.31286 ↗
47. Influence of thermal annealing on the mechanical properties of PLLA coiled stents10.1007/s13239-014-0189-3 ↗
48. Evaluation of the biodegradable igaki-tamai scaffold after drug-eluting balloon treatment of de novo superficial femoral artery lesions: the GAIA-DEB study10.1177/1526602815620618 ↗
49. Xudong, J., Haiquan, F., Zhiyong, H., Qingsong, H., 2012. Numerical investigation of the radial supporting stiffness and bending inflexibility for intravascular coronary stents. In: International Conference on Mechanic Automation & Control Engineering. pp. 3712–3716.
50. A novel potential ecomaterial based on Poly(p-Dioxanone)/Montmorillonite nanocomposite with improved crystalline, processing, and mechanical properties10.1080/00222340903035170 ↗
51. Mechanical characteristics of novel polyester/NiTi wires braided composite stent for the medical application10.1016/j.rinp.2016.07.007 ↗
52. A resorbable bicomponent braided ureteral stent with improved mechanical performance10.1016/j.jmbbm.2014.06.004 ↗