On the observation of lubrication mechanisms within hip joint replacements. Part I: Hard-on-soft bearing pairs
Source abstract
Abstract
The present study describes the lubrication mechanisms within artificial hip joints considering real conformity of rubbing surfaces. Part I is focused on hard-on-soft material combination, introducing the fundamentals of lubrication performance. These pairs have not been explored in terms of in situ observation before. The contact of metal femoral component articulating with transparent polymer acetabular cup was studied using a hip joint simulator. The film formation was evaluated by fluorescent microscopy method. Various model synovial fluids were employed while the key constituents, i.e. albumin, γ-globulin, and hyaluronic acid were fluorescently stained to determine its role in film formation process. Two types of the tests were performed. The first dynamic test aimed on the development of film thickness under constant load during motor driven swinging motion mimicking flexion-extension. Subsequently, a combined test was designed consisting of the three phases; static part with loading/unloading phase (1), pendulum swinging till spontaneous damping of the motion due to friction (2), and static observation under the constant load (3). The results clearly confirmed that the interaction of constituents of synovial fluid plays a dominant role and substantially influences the lubrication conditions. In particular, the main finding coming from the present study is that γ-globulin together with hyaluronic acid form relatively thin stable boundary layer enabling the enhanced adsorption of albumin, thus increasing the lubricant film. Part II of the present study is focused on hard-on-hard pairs while the main differences in film formation process are highlighted among others.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Hip disorders and treatments · Total Knee Arthroplasty Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (57)
Show source-provided references
1. A review of in situ methodologies for studying elastohydrodynamic lubrication10.1177/1350650115590428 ↗
2. In situ 3D measurement of lubrication behavior at interface between tool and workpiece by direct fluorescence observation technique10.1016/j.wear.2005.01.053 ↗
3. The influence of clearance on friction, lubrication and squeaking in large diameter metal-on-metal hip replacements
4. . Fabrication and characterization of DLC coated microdimples on hip prosthesis heads10.1002/jbm.b.33274 ↗
5. A novel tribological study on DLC-coated micro-dimpled orthopedics implant interface10.1016/j.jmbbm.2014.11.028 ↗
6. Enhanced lubricant film formation through micro-dimpled hard-on-hard artificial hip joint: an in-situ observation of dimple shape effects10.1016/j.jmbbm.2018.02.014 ↗
7. Friction, lubrication, and polymer transfer between UHMWPE and CoCrMo hip-implant materials: a fluorescence microscopy study10.1002/jbm.a.32036 ↗
8. Secondary structure of 11 S globulin in aqueous solution investigated by FT-IR derivative spectroscopy10.1016/0167-4838(88)90283-X ↗
9. A hip joint simulator study of the performance of metal-on-metal joints
10. Effect of femoral head size on contact pressure and wear in total hip arthroplasty
11. Laser-based fluorescence techniques for measuring thin liquid films10.1016/0043-1648(78)90267-3 ↗
12. A study of lubricant film thickness in compliant contacts of elastomeric seal materials using a laser induced fluorescence technique10.1016/j.triboint.2014.05.028 ↗
13. Characteristics of synovial fluid required for optimization of lubrication fluid for biotribological experiments10.1002/jbm.b.33663 ↗
14. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements10.1243/0954411001535228 ↗
15. Contact mechanics of modular metal-on-polyethylene total hip replacement under adverse edge loading conditions10.1016/j.jbiomech.2014.08.015 ↗
16. Thin film colorimetric interferometry10.1080/10402000108982458 ↗
17. Haugland · 1996
18. Bearing surface options for total hip replacement in young patients10.2106/00004623-200307000-00026 ↗
19. Protein-mediated boundary lubrication in arthroplasty10.1016/j.biomaterials.2004.05.020 ↗
20. Emission reabsorption laser induced fluorescence (ERLIF) film thickness measurement10.1088/0957-0233/12/4/310 ↗
21. NMR analysis of synthetic human serum albumin α-helix 28 identifies Structural distortion upon amadori modification10.1074/jbc.M501480200 ↗
22. Sports activities 5 years after total knee or hip arthroplasty: the Ulm Osteoarthritis Study10.1136/ard.2004.033266 ↗
23. Holzwarth · 2012 · 2012
24. Determination of chromium in waste-water and cast iron samples by fluorescence quenching of rhodamine 6G10.1016/S0039-9140(97)00261-0 ↗
25. Lakowicz · 2006
26. Friction and lubricant film thickness measurements on simulated synovial fluids10.1243/13506501JET580 ↗
27. Lubricating film thickness measurements with bovine serum10.1016/j.triboint.2010.07.008 ↗
28. The John Charnley Award paper: the role of joint fluid in the tribology of total joint arthroplasty10.1097/01.blo.0000150315.47697.b9 ↗
29. Damage of an Oxinium femoral head and polyethylene liner following ‘routine’ total hip replacement10.1302/0301-620X.93B3.25327 ↗
30. Laser-induced fluorescence for film thickness mapping in pure sliding lubricated, compliant, contacts10.1016/j.triboint.2010.03.013 ↗
31. Lubrication of metal-on-metal hip joints: the effect of protein content and load on film formation and wear10.1016/j.jmbbm.2011.09.008 ↗
32. On the matter of synovial fluid lubrication: implications for metal-on-metal hip tribology10.1016/j.jmbbm.2013.12.016 ↗
33. Lubrication within hip replacements – implication for ceramic-on-hard bearing couples10.1016/j.jmbbm.2016.04.003 ↗
34. The effect of lubricant constituents on lubrication mechanisms in hip joint replacements10.1016/j.jmbbm.2015.11.006 ↗
35. The influence of proteins and speed on friction and adsorption of metal/UHMWPE contact pair10.1016/j.biotri.2017.03.003 ↗
36. In situ observation of lubricant film formation in thr considering real conformity: the effect of diameter, clearance and material10.1016/j.jmbbm.2016.12.018 ↗
37. On the observation of lubrication mechanisms within hip joint replacements. Part II: Hard-on-hard bearing pairs
38. The effect of kinematic conditions on film thickness in compliant lubricated contact10.1115/1.4039529 ↗
39. In situ observation of lubricant film formation in thr considering real conformity: the effect of model synovial fluid composition10.1016/j.triboint.2017.09.001 ↗
40. Wear analysis of extracted polyethylene acetabular cups using a 3D optical scanner10.1080/10402004.2016.1176286 ↗
41. Normal range of motion of the hip, knee and ankle joints in male subjects, 30–40 years of age10.3109/17453678208992202 ↗
42. Effect of synovia constituents on friction and wear of ultra-high molecular weight polyethylene sliding against prosthetic joint materials10.1016/S0043-1648(97)00196-8 ↗
43. Influence of protein and lipid concentration of the test lubricant on the wear of ultra high molecular weight polyethylene10.1016/j.triboint.2007.11.010 ↗
44. Adsorption of albumin on prosthetic materials: implication for tribological behavior10.1002/jbm.a.30754 ↗
45. The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements10.1243/0954411011533724 ↗
46. Thin films in elastohydrodynamic lubrication: the contribution of experiment10.1243/1350650991542712 ↗
47. Boundary lubrication in engineering practice
48. Sugimura, J., Hashimoto, M., Yamamoto, Y., 2000. Study of elastohydrodynamic contacts with fluorescence microscope, In: Thinning Films And Tribological Interfaces, Proceedings of the 26Th Leeds-Lyon Symposium On Tribology, Tribology Series, Elsevier, pp. 609–617.10.1016/S0167-8922(00)80165-0 ↗
49. The molecular structure and lubricating activity of lubricin isolated from bovine and human synovial fluids10.1042/bj2250195 ↗
50. Importance of preclinical evaluation of wear in hip implant designs using simulator machines10.1016/j.rbo.2016.07.009 ↗
51. Recent developments in the tribology of artificial joints10.1016/0301-679X(95)00027-2 ↗
52. In situ measurements of thin films in bovine serum lubricated contacts using optical interferometry10.1177/0954411913517498 ↗
53. Determination of a friction coefficient for THA bearing couples10.55095/achot2015/057 ↗
54. Visualization of lubricating films between artificial head and cup with respect to real geometry10.1016/j.biotri.2015.05.002 ↗
55. Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements10.1016/S0301-679X(98)00005-X ↗
56. The effects of lubricant composition onin vitro wear testing of polymeric acetabular components10.1002/jbm.b.10077 ↗
57. Influence of polymer surface chemistry on frictional properties under protein-lubrication conditions: implications for hip-implant design10.1023/A:1009074228662 ↗