journal article·2019-10

Experimental study on the loosening of pedicle screws implanted to synthetic bone vertebra models and under non-pull-out mechanical loads

Bartosz Nowak

Publisher page

Abstract

Background Pull-out tests have been widely applied to orthopaedic devices such as pedicle screws for the last decades. Despite their wide applicability, this particular pedicle screw testing method does not represent the load pattern of implanted vertebrae with the use of pedicle screw spinal constructs. Purpose In the present study a new custom made foam model (Sawbone) of human vertebra and a corresponding load pattern for pedicle screw spinal implant construct were introduced. They allow for the investigation of loosening at the bone-screw interface and constitute an alternative test method to pullout tests. Methods The new custom made foam model of human vertebra was developed and made out of biomechanical materials Sawbones in three different variants, including varied density in order to simulate normal, osteopenic, and osteoporotic quality of bone. Mechanical testing methods followed reproducible, non-pull-out loading protocols based originally on the ASTM F- 1717 standard which enables to introduce loosening at the bone-screw interface. Results The results include the pattern of screw loosening at the bone-screw interface, measured loosening area at the interface, and mechanical parameters characterising bone-screw interface such as initial stiffness and residual displacements. Conclusions The new custom made foam model of human vertebra followed by non-pull-out load protocol enabled investigations of the loosening at the bone-screw interface. During the tests a characteristic toggling profile of loosening was found with a significant widening at the tip of the screw for the osteoporotic quality of bone. It was proposed that the model and the corresponding load protocol may extend the current testing methods based on the pull-out testing, leading to the more accurate testing of pedicle screw spinal constructs focused on the bone-implant interface.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Spinal Fractures and Fixation Techniques · Spine and Intervertebral Disc Pathology · Pelvic and Acetabular Injuries

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (17)

Show source-provided references
1. An · 2002
2. The biomechanics of pedicle screw-based instrumentation
3. The effect of repetitive pilot-hole use on the insertion torque and pullout strength of vertebral system screws10.1097/BRS.0b013e31819e3556 ↗
4. The use of pedicle-screw internal fixation for the operative treatment of spinal disorders10.2106/00004623-200010000-00013 ↗
5. Pullout strength of pedicle screws augmented with particulate calcium phosphate: an experimental study10.1016/j.spinee.2008.07.001 ↗
6. Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses10.1016/j.orthres.2004.11.002 ↗
7. Pedicle screw fixation strength: pullout versus insertional torque10.1016/j.spinee.2004.02.006 ↗
8. A case of pedicle screw loosening treated by modified transpedicular screw augmentation with polymethylmethacrylate10.3340/jkns.2011.49.1.75 ↗
9. Biomechanics of thoracolumbar spinal fixation: a review10.1097/00007632-199103001-00014 ↗
10. Krenn · 2008
11. Caudo-cephalad loading of pedicle screws: mechanisms of loosening and methods of augmentation10.1097/00007632-199312000-00012 ↗
12. Complications of transpedicular lumbosacral fixation for non-traumatic disorders10.1302/0301-620X.79B2.0790183 ↗
13. Loads on an internal spinal fixation device during walking10.1016/S0021-9290(96)00103-0 ↗
14. Monitoring in vivo implant loads with a telemeterized internal spinal fixation device10.1097/00007632-200012010-00004 ↗
15. Schmoelz · 2011
16. Schulze · 2011
17. Fatigue of closed-cell foams in compression10.1177/1099636210386847 ↗