journal article·2021-01Open access

Subject-specific FE models of the human femur predict fracture path and bone strength under single-leg-stance loading

Anna Gustafsson, Martina Tognini, Frida Bengtsson, T. Christian Gasser, Hanna Isaksson, Lorenzo Grassi

Abstract

Hip fractures are a major health problem with high socio-economic costs. Subject-specific finite element (FE) models have been suggested to improve the fracture risk assessment, as compared to clinical tools based on areal bone mineral density, by adding an estimate of bone strength. Typically, such FE models are limited to estimate bone strength and possibly the fracture onset, but do not model the fracture process itself. The aim of this study was to use a discrete damage approach to simulate the full fracture process in subject-specific femur models under stance loading conditions. A framework based on the partition of unity finite element method (PUFEM), also known as XFEM, was used. An existing PUFEM framework previously used on a homogeneous generic femur model was extended to include a heterogeneous material description together with a strain-based criterion for crack initiation. The model was tested on two femurs, previously mechanically tested in vitro. Our results illustrate the importance of implementing a subject-specific material distribution to capture the experimental fracture pattern under stance loading. Our models accurately predicted the fracture pattern and bone strength (1% and 5% error) in both investigated femurs. This is the first study to simulate complete fracture paths in subject-specific FE femur models and it demonstrated how discrete damage models can provide a more complete picture of fracture risk by considering both bone strength and fracture toughness in a subject-specific fashion.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Hip disorders and treatments · Bone health and osteoporosis research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (56)

Show source-provided references
1. Specimen-specific modeling of hip fracture pattern and repair10.1016/j.jbiomech.2013.10.033 ↗
2. Characterization of the effects of x-ray irradiation on the hierarchical structure and mechanical properties of human cortical bone10.1016/j.biomaterials.2011.08.013 ↗
3. Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue10.1016/S0021-9290(03)00257-4 ↗
4. Fracture-mechanics of bone - the effects of density, specimen thickness and crack velocity on longitudinal fracture10.1016/0021-9290(84)90076-9 ↗
5. Prediction of proximal femur strength using a CT-based nonlinear finite element method: differences in predicted fracture load and site with changing load and boundary conditions10.1016/j.bone.2009.04.241 ↗
6. Perspectives on the non-invasive evaluation of femoral strength in the assessment of hip fracture risk10.1007/s00198-019-05195-0 ↗
7. Reduction of mesh sensitivity in continuum damage mechanics10.1007/BF01215415 ↗
8. Bone loss at the hip and subsequent mortality in older men: the osteoporotic fractures in men (MrOS) study10.1002/jbm4.10006 ↗
9. Femoral strength is better predicted by finite element models than QCT and DXA10.1016/S0021-9290(99)00099-8 ↗
10. The fracture toughness of cancellous bone10.1016/j.jbiomech.2009.06.001 ↗
11. Functional outcomes and mortality vary among different types of hip fractures - a function of patient characteristics10.1097/01.blo.0000132406.37763.b3 ↗
12. Tensile and compressive stress yield criteria for cancellous bone10.1016/j.jbiomech.2004.03.003 ↗
13. Tensile yield in compact bone is determined by strain, post-yield behaviour by mineral content10.1016/j.jbiomech.2003.08.008 ↗
14. A nonlinear QCT-based finite element model validation study for the human femur tested in two configurations in vitro10.1016/j.bone.2012.09.006 ↗
15. Numerical aspects of cohesive-zone models10.1016/S0013-7944(03)00122-X ↗
16. Anisotropic mode-dependent damage of cortical bone using the extended finite element method (XFEM)10.1016/j.jmbbm.2012.12.004 ↗
17. Cortical bone failure mechanisms during screw pullout10.1016/j.jbiomech.2012.03.023 ↗
18. Empirical relationships between bone density and ultimate strength: a literature review10.1016/j.jmbbm.2020.103866 ↗
19. Explicit finite element models accurately predict subject-specific and velocity-dependent kinetics of sideways fall impact10.1002/jbmr.3804 ↗
20. The dependence of shear failure properties of trabecular bone on apparent density and trabecular orientation10.1016/0021-9290(96)00062-0 ↗
21. Modeling 3D crack propagation in unreinforced concrete using PUFEM
22. 3D Crack propagation in unreinforced concrete. A two-step algorithm for tracking 3D crack paths
23. A numerical framework to model 3-D fracture in bone tissue with application to failure of the proximal femur10.1007/978-1-4020-6530-9_12 ↗
24. Prevalent role of porosity and osteonal area over mineralization heterogeneity in the fracture toughness of human cortical bone10.1016/j.jbiomech.2016.06.009 ↗
25. Elucidating failure mechanisms in human femurs during a fall to the side using bilateral digital image correlation10.1016/j.jbiomech.2020.109826 ↗
26. Prediction of femoral strength using 3D finite element models reconstructed from DXA images: validation against experiments10.1007/s10237-016-0866-2 ↗
27. How accurately can subject-specific finite element models predict strains and strength of human femora ? Investigation using full-field measurements10.1016/j.jbiomech.2016.02.032 ↗
28. Full-field strain measurement during mechanical testing of the human femur at physiologically relevant strain rates10.1115/1.4028415 ↗
29. Age-related properties at the microscale affect crack propagation in cortical bone10.1016/j.jbiomech.2019.109326 ↗
30. A quasi-brittle continuum damage finite element model of the human proximal femur based on element deletion10.1007/s11517-012-0986-5 ↗
31. The influence of the modulus-density relationship and the material mapping method on the simulated mechanical response of the proximal femur in side-ways fall loading configuration10.1016/j.medengphy.2016.03.006 ↗
32. Understanding bone strength is not enough10.1002/jbmr.3078 ↗
33. Osteoporosis in the European union: medical management, epidemiology and economic burden. A report prepared in collaboration with the International Osteoporosis Foundation (IOF) and the European Federation of Pharmaceutical Industry Associations (EFPIA)10.1007/s11657-013-0136-1 ↗
34. An estimate of the worldwide prevalence and disability associated with osteoporotic fractures10.1007/s00198-006-0172-4 ↗
35. European guidance for the diagnosis and management of osteoporosis in postmenopausal women10.1007/s00198-018-4704-5 ↗
36. Biomechanical Computed Tomography analysis (BCT) for clinical assessment of osteoporosis10.1007/s00198-020-05384-2 ↗
37. Ct-based finite element models can be used to estimate experimentally measured failure loads in the proximal femur10.1016/j.bone.2012.01.012 ↗
38. Mortality, disability, and nursing home use for persons with and without hip fracture: a population-based study10.1046/j.1532-5415.2002.50455.x ↗
39. Fracture prediction for the proximal femur using finite-element models .1. Linear-analysis10.1115/1.2895412 ↗
40. Fracture prediction for the proximal femur using finite-element models .2. Nonlinear-analysis10.1115/1.2895413 ↗
41. Numerical modelling of hip fracture patterns in human femur10.1016/j.cmpb.2019.03.010 ↗
42. Modelling of femur fracture using finite element procedures10.1016/j.engfracmech.2018.04.024 ↗
43. Time-elapsed synchrotron-light microstructural imaging of femoral neck fracture10.1016/j.jmbbm.2018.05.016 ↗
44. Trabecular bone modulus-density relationships depend on anatomic site10.1016/S0021-9290(03)00071-X ↗
45. Dependence of yield strain of human trabecular bone on anatomic site10.1016/S0021-9290(01)00011-2 ↗
46. Proximal femur bone strength estimated by a computationally fast finite element analysis in a sideways fall configuration10.1016/j.jbiomech.2013.02.025 ↗
47. Modelling strong discontinuities in solid mechanics via strain softening constitutive equations. Part 1: Fundamentals10.1002/(SICI)1097-0207(19961115)39:21<3575::AID-NME65>3.0.CO;2-E ↗
48. The population burden of fractures originates in women with osteopenia, not osteoporosis10.1007/s00198-006-0135-9 ↗
49. To what extent can linear finite element models of human femora predict failure under stance and fall loading configurations?10.1016/j.jbiomech.2014.08.024 ↗
50. An accurate estimation of bone density improves the accuracy of subject-specific finite element models10.1016/j.jbiomech.2008.05.017 ↗
51. A novel phase field method for modeling the fracture of long bones
52. The material mapping strategy influences the accuracy of CT-based finite element models of bones: an evaluation against experimental measurements10.1016/j.medengphy.2006.10.014 ↗
53. Taylor · 2000
54. Hip fractures - treatment and functional outcome. The development over 25 years10.1016/j.injury.2018.10.010 ↗
55. Hip fracture in women without osteoporosis10.1210/jc.2004-1568 ↗
56. Influence of bone composition and apparent density on fracture toughness of the human femur and tibia10.1016/S8756-3282(97)00227-5 ↗