Specimen specific parameter identification of ovine lumbar intervertebral discs: On the influence of fibre–matrix and fibre–fibre shear interactions
Source abstract
Abstract
Numerical models of the intervertebral disc, which address mechanical questions commonly make use of the difference in water content between annulus and nucleus, and thus fluid and solid parts are separated. Despite this simplification, models remain complex due to the anisotropy and nonlinearity of the annulus and regional variations of the collagen fibre density. Additionally, it has been shown that cross-links make a large contribution to the stiffness of the annulus. Because of this complex composite structure, it is difficult to reproduce several sets of experimental data with one single set of material parameters. This study addresses the question to which extent the ultrastructure of the intervertebral disc should be modelled so that its moment-angle behaviour can be adequately described. Therefore, a hyperelastic constitutive law, based on continuum mechanical principles was derived, which does not only consider the anisotropy from the collagen fibres, but also interactions among the fibres and between the fibres and the ground substance. Eight ovine lumbar intervertebral discs were tested on a custom made spinal loading simulator in flexion/extension, lateral bending and axial rotation. Specimen-specific geometrical models were generated using CT images and T2 maps to distinguish between annulus fibrosus and nucleus pulposus. For the identification of the material parameters the annulus fibrosus was described with two scenarios: with and without fibre-matrix and fibre-fibre interactions. Both scenarios showed a similar behaviour on a load displacement level. Comparing model predictions to the experimental data, the mean RMS of all specimens and all load cases was 0.54±0.15° without the interaction and 0.54±0.19° when the fibre-matrix and fibre-fibre interactions were included. However, due to the increased stiffness when cross-links effects were included, this scenario showed more physiological stress-strain relations in uniaxial and biaxial stress states. Thus, the present study suggests that fibre-matrix and fibre-fibre interactions should be considered in the constitutive law when the model addresses questions concerning the stress field of the annulus fibrosus.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Spine and Intervertebral Disc Pathology · Musculoskeletal pain and rehabilitation · Medical Imaging and Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (39)
Show source-provided references
1. Tensile properties of the annulus fibrosus. I. The contribution of fibre–matrix interactions to tensile stiffness and strength10.1007/BF00299447 ↗
2. The micromechanical role of the annulus fibrosus components under physiological loading of the lumbar spine10.1115/1.4001032 ↗
3. Biaxial testing of human annulus fibrosus and its implications for a constitutive formulation10.1114/B:ABME.0000039357.70905.94 ↗
4. Belytschko · 2001
5. Is the chemistry of collagen in intervertebral discs an expression of wolff's law? A study of the human lumbar spine10.1097/00007632-198403000-00005 ↗
6. Issls prize winner10.1097/01.brs.0000146465.05972.56 ↗
7. Hyperelastic anisotropic microplane constitutive model for annulus fibrosus10.1115/1.2768378 ↗
8. Hierarchical structure of the intervertebral disc10.3109/03008208909103905 ↗
9. Effects of exogenous crosslinking on in vitro tensile and compressive moduli of lumbar intervertebral discs10.1016/j.clinbiomech.2006.08.001 ↗
10. Tensile properties of nondegenerate human lumbar anulus fibrosus10.1097/00007632-199602150-00009 ↗
11. Multi-segment FEA of the human lumbar spine including the heterogeneity of the annulus fibrosus
12. An anisotropic model for annulus tissue and enhanced finite element analyses of intact lumbar disc bodies10.1080/10255840108908005 ↗
13. A linear material model for fiber-induced anisotropy of the anulus fibrosus10.1115/1.429639 ↗
14. Anisotropic and inhomogeneous tensile behavior of the human anulus fibrosus10.1115/1.1374202 ↗
15. Calibration of the finite element model of a lumbar functional spinal unit using an optimization technique based on differential evolution10.1016/j.medengphy.2010.09.010 ↗
16. Anisotropic shear behavior of the annulus fibrosus10.1016/S1350-4533(00)00053-9 ↗
17. Minimizing errors during in vitro testing of multisegmental spine specimens10.1016/j.jbiomech.2006.07.024 ↗
18. Fibre–matrix interaction in the human annulus fibrosus10.1016/j.jmbbm.2011.05.041 ↗
19. Stepwise reduction of functional spinal structures increase range of motion and change lordosis angle10.1016/j.jbiomech.2006.01.007 ↗
20. Holzapfel · 2006
21. Single lamellar mechanics of the human lumbar annulus fibrosus10.1007/s10237-004-0053-8 ↗
22. Is the nucleus pulposus a solid or a fluid? Mechanical behaviors of the nucleus pulposus of the human intervertebral disc10.1097/00007632-199605150-00009 ↗
23. Three-dimensional observation of collagen framework of lumbar intervertebral discs10.3109/17453677508989283 ↗
24. T2 relaxation times of intervertebral disc tissue correlated with water content and proteoglycan content10.1097/BRS.0b013e318195dd44 ↗
25. A general polyconvex strain-energy function for fiber-reinforced materials10.1002/pamm.200510099 ↗
26. Measurement of local strains in intervertebral disc anulus fibrosus tissue under dynamic shear10.1016/j.jbiomech.2009.06.047 ↗
27. Geometry strongly influences the response of numerical models of the lumbar spine—a probabilistic finite element analysis10.1016/j.jbiomech.2012.02.021 ↗
28. On the collagen criss-cross angles in the annuli fibrosi of lumbar spine finite element models10.1007/s10237-010-0227-5 ↗
29. How does the geometry affect the internal biomechanics of a lumbar spine bi-segment finite element model? consequences on the validation process10.1016/j.jbiomech.2006.11.021 ↗
30. An anisotropic hyperelastic model with fiber-matrix shear interaction for the human annulus fibrosus10.1115/1.2069987 ↗
31. pyopt10.1007/s00158-011-0666-3 ↗
32. Sheep lumbar intervertebral discs as models for human discs10.1016/S0268-0033(02)00009-8 ↗
33. On the physical assumptions underlying the volumetric-isochoric split and the case of anisotropy10.1016/j.euromechsol.2007.04.001 ↗
34. Application of a new calibration method for a three-dimensional finite element model of a human lumbar annulus fibrosus10.1016/j.clinbiomech.2005.12.001 ↗
35. Analysis of role of bone compliance on mechanics of a lumbar motion segment10.1115/1.2895791 ↗
36. Regional variation in tensile properties and biochemical composition of the human lumbar anulus fibrosus10.1097/00007632-199406000-00002 ↗
37. Swelling pressure of the lumbar intervertebral discs10.1097/00007632-198802000-00009 ↗
38. Determination of the translational and rotational stiffnesses of an l4-l5 functional spinal unit using a specimen-specific finite element model10.1016/j.jmbbm.2012.04.002 ↗
39. White · 1990