Uniaxial and biaxial mechanical characterization of a prosthetic mesh at different length scales
Source abstract
Abstract
This study is aimed at a comprehensive experimental analysis of the mechanical behavior of a prosthetic mesh considering different length scales. Uniaxial and biaxial protocols are developed to evaluate global mechanical phenomena of the dry mesh. Furthermore, procedures for local deformation analysis and evaluation of corresponding homogenized kinematic measures are described. The global mechanical response of the prosthetic mesh is characterized by anisotropy, a nonlinear force response, hysteresis and preconditioning effects. The local deformation analysis allows to identify mesh specific phenomena related to mechanisms at the unit cell level. The global and the local kinematic responses of the mesh are seen to be directly related to clinical observations and help to understand associated complications, such as wrinkle formation, dislocation or erosion. In that sense, this study contributes to the analysis of mechanical biocompatibility of mesh implants and proposes protocols for comprehensive mesh product descriptions.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Hernia repair and management · Orthopaedic implants and arthroplasty · Elasticity and Material Modeling
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. Tissue mechanics, animal models, and pelvic organ prolapse10.1016/j.ejogrb.2009.02.022 ↗
2. A mesoscopic approach for the simulation of woven fibre composite forming10.1016/j.compscitech.2004.09.024 ↗
3. Characterization of mechanical behavior of woven fabrics10.1016/j.compositesa.2008.02.016 ↗
4. The argument for lightweight polypropylene mesh in hernia repair10.1177/155335060501200109 ↗
5. Physicomechanical evaluation of polypropylene, polyester, and polytetrafluoroethylene meshes for inguinal hernia repair10.1016/j.jamcollsurg.2010.09.012 ↗
6. Effect of repetitive loading on the mechanical properties of synthetic hernia repair materials10.1016/j.jamcollsurg.2011.05.018 ↗
7. Fung · 1993
8. Vagina, abdominal skin, and aponeurosis10.1007/s00192-010-1237-7 ↗
9. Characterising the shear-tension coupling and wrinkling behaviour of woven engineering fabrics10.1016/j.compositesa.2012.01.024 ↗
10. Normalization of shear test data for rate-independent compressible fabrics10.1177/0021998308095367 ↗
11. Mechanical behaviour of synthetic surgical meshes10.1016/j.actbio.2011.06.033 ↗
12. Biomechanical properties of lightweight versus heavyweight meshes for laparoscopic inguinal hernia repair and their impact on recurrence rates10.1007/s00464-008-9936-6 ↗
13. Strain mapping analysis of textile composites10.1016/j.optlaseng.2008.05.013 ↗
14. Tensile properties of commonly used prolapse meshes10.1007/s00192-008-0781-x ↗
15. Influence of polyglecaprone 25 (monocryl) supplementation on the biocompatibility of a polypropylene mesh for hernia repair10.1007/s10029-004-0315-5 ↗
16. The lightweight and large porous mesh concept for hernia repair10.1586/17434440.2.1.103 ↗
17. Biomechanical properties of raw meshes used in pelvic floor reconstruction10.1007/s00192-008-0711-y ↗
18. Multi-scale study of tensile properties and large deformation mechanisms of polyethylene terephthalate/polypropylene knitted composites10.1016/S0266-3538(02)00077-5 ↗
19. Full-field strain measurements in textile deformability studies10.1016/j.compositesa.2007.09.014 ↗
20. A comparison of suture repair with mesh repair for incisional hernia10.1056/NEJM200008103430603 ↗
21. Persistence of polypropylene mesh anisotropy after implantation10.1111/j.1471-0528.2011.03018.x ↗
22. Shrinkage and biomechanical evaluation of lightweight synthetics in a rabbit model for primary fascial repair10.1007/s00192-011-1440-1 ↗
23. Experimental and numerical analysis on normalization of picture frame tests for composite materials10.1016/S0266-3538(03)00202-1 ↗
24. Measurement of meso-scale shear deformations for modelling textile composites10.1016/j.compositesa.2005.03.032 ↗
25. A non-biological model system to simulate the in vivo mechanical behavior of prosthetic meshes10.1016/j.jmbbm.2013.01.029 ↗
26. Combined biaxial and uniaxial mechanical characterization of prosthetic meshes in a rabbit model10.1016/j.jbiomech.2013.04.015 ↗
27. Uniaxial biomechanical properties of seven different vaginally implanted meshes for pelvic organ prolapse10.1007/s00192-011-1616-8 ↗
28. Study on large deformation characteristics of knitted fabric reinforced thermoplastic composites at forming temperature by digital image-based strain measurement technique10.1016/j.compscitech.2004.03.016 ↗
29. US Food and Drug Administration, 2011. FDA safety communication: update on serious complications associated with transvaginal placement of surgical mesh for pelvic organ prolapse. 〈www.fdagov/MedicalDevices/Safety/AlertsandNotices/ucm262435htm〉.
30. Large deformation and slippage mechanism of plain woven composite in bias extension10.1016/j.compositesa.2007.04.009 ↗