journal article·2019-02

Implant-to-bone force transmission: a pilot study for in vivo strain gauge measurement technique

Fabio Cozzolino, Davide Apicella, Guixue Wang, Antonio Apicella, Roberto Sorrentino

Publisher page

Abstract

The experimental determination of local bone deformations due to implant loading would allow for a better understanding of the biomechanical behavior of the bone-implant-prosthesis system as well as the influence of uneven force distribution on the onset of implant complications. The present study aimed at describing an innovative in vivo strain gauge measurement technique to evaluate implant-to-bone force transmission, assessing whether and how oral implants can transfer occlusal forces through maxillary bones. In vivo force measurements were performed in the maxillary premolar region of a male patient who had previously received a successful osseointegrated titanium implant. Three linear mini-strain gauges were bonded onto three different buccal cortical bone locations (i.e. coronal, middle, apical) and connected to strain measuring hardware and software. A customized screw-retained abutment was manufactured to allow for vertical and horizontal loading tests. As to the vertical load test, the patient was instructed to bite on a load cell applying his maximum occlusal force for 20 s and then recovering for 10 s to restore the bone unstrained state; the test was repeated 20 times consecutively. As regards the horizontal load test, the implant was subjected to a total of 20 load applications with force intensities of 5 and 10 kg. During the tests, the recorded signals were plotted in real time on a graph as a function of time by means of a strain analysis software. The described strain gauge measurement technique proved to be effective in recording the forces transmitted from osseointegrated implants to the cortical bone. Horizontal loads caused higher deformations of cortical bone than vertical biting forces; in both situations, the deformation induced by the force transferred from the implant to the bone progressively decreased from the coronal to the apical third of the alveolar ridge. At approximately 9 mm from the implant neck, the effect of occlusal force transmission through osseointegrated titanium implants was negligible if compared to the apical region.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. Maximum bite force following unilateral implant-supported prosthetic treatment: within-subject comparison to opposite dental side10.1111/joor.12174 ↗
2. An · 1999 · 305
3. Influence of abutment material on the fracture strength and failure modes of abutment-fixture assemblies when loaded in a bio-faithful simulation10.1111/j.1600-0501.2010.01979.x ↗
4. Direct restoration modalities of fractured central maxillary incisors: a multi-levels validated finite elements analysis with in vivo strain measurements10.1016/j.dental.2015.09.016 ↗
5. Methods used to assess implant stabilty: current status
6. Osseointegration of titanium, titanium alloy and zirconia dental implants: current knowledge and open questions10.1111/prd.12179 ↗
7. Discrimination of a right angle with monocular and cyclopic perception10.1007/s10747-005-0064-6 ↗
8. Impact of excessive occlusal load on successfully-osseointegrated dental implants: a literature review10.1111/jicd.12036 ↗
9. The effect of loading on peri-implant bone: a critical review of the literature10.1111/joor.12195 ↗
10. Chewing efficiency, bite force and oral health-related quality of life with narrow diameter implants - a prospective clinical study: results after one year10.1111/clr.12822 ↗
11. Bite force and dental implant treatment: a short review10.2147/MDER.S130314 ↗
12. A 2003 update of bone physiology and Wolff's Law for clinicians
13. International Ethical Guidelines for Biomedical Research Involving Human Subjects, CIOMS/WHO, 2002.
14. Influence of forces on peri-implant bone10.1111/j.1600-0501.2006.01360.x ↗
15. The past, present, and future of bone morphometry: its contribution to an improved understanding of bone biology
16. Maximum bite force of edentulous patients before and after dental implant rehabilitation: long-term follow-up and facial type influence
17. In vivo force measurements on maxillary implants supporting a fixed prosthesis or an overdenture: a pilot study10.1067/mpr.2000.110264 ↗
18. Measurement of masticatory forces and implant loads: a methodologic clinical study
19. Dental implants press fit phenomena: biomechanics analysis considering bone inelastic response10.1016/j.dental.2008.11.002 ↗
20. Development of computerized masticatory force measurement system10.1080/03091902.2016.1218559 ↗
21. Evaluation of molar and incisor bite force in indigenous compared with white population in Brazil10.1016/j.archoralbio.2007.10.003 ↗
22. Variations in cortical material properties throughout the human dentate mandible10.1002/ajpa.10121 ↗
23. The role of occlusion in implant therapy: a comprehensive updated review10.1097/ID.0000000000000488 ↗
24. Analysis of the causes of dental implant fracture: a retrospective clinical study
25. Effects of occlusal rest design on pressure distribution beneath the denture base of a distal extension removable partial denture-an in vivo study10.11607/ijp.3847 ↗
26. EAO supplement working Group 4 - EAO CC 2015 short implants versus sinus lifting with longer implants to restore the posterior maxilla: a systematic review10.1111/clr.12615 ↗
27. Bite force and electromyograpy during maximum unilateral and bilateral clenching10.1111/j.1600-0722.2008.00531.x ↗