Abstract
Computational simulations of Transcatheter Aortic Valve Implantation (TAVI) have reached a high level of complexity and accuracy for the prediction of possible implantation scenarios during the decision-making process. However, when focusing on the prosthetic device, currently different devices are available on the market which not only have different geometries, but also different material properties. The present work focuses on the calibration of Nitinol constitutive parameters of four self-expandable devices starting from experimental radial force tests on the prosthetic samples. Beside providing optimal material properties for each specific device, we also perform a patient-specific simulation, comparing the results obtained using both "literature" and calibrated parameters with the aim of investigating the impact of metallic frame parameters choice on simulation results.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Cardiac Valve Diseases and Treatments · Infective Endocarditis Diagnosis and Management · Aortic Disease and Treatment Approaches
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (31)
Show source-provided references
1. Shape-memory alloys: modelling and numerical simulations the finite strain superelastic behavior
2. Assessing the impact of including leaflets in the simulation of TAVI deployment into a patient-specific aortic root10.1080/10255842.2015.1058928 ↗
3. Patient-specific simulation of transcatheter aortic valve replacement: impact of deployment options on paravalvular leakage10.1007/s10237-018-1094-8 ↗
4. Population-specific material properties of the implantation site for transcatheter aortic valve replacement finite element simulations10.1016/j.jbiomech.2018.02.017 ↗
5. Understanding the requirements of self-expandable stents for heart valve replacement: radial force, hoop force and equilibrium
6. Radial force: an underestimated parameter in oversizing transcatheter aortic valve replacement prostheses: in vitro analysis with five commercialized valves10.1097/MAT.0000000000000659 ↗
7. Transcatheter aortic valve implantation (TAVI): valve design and evolution10.1016/j.ijcard.2013.07.117 ↗
8. Finite element analysis of TAVI: impact of native aortic root computational modeling strategies on simulation outcomes10.1016/j.medengphy.2017.06.045 ↗
9. Performance of high conformability vs. high radial force devices in the virtual treatment of TAVI patients with bicuspid aortic valve10.1016/j.medengphy.2021.02.004 ↗
10. Numerical evaluation of transcatheter aortic valve performance during heart beating and its post-deployment fluid-structure interaction analysis10.1007/s10237-020-01304-9 ↗
11. Transcatheter aortic valve implantation with Portico and Evolut-R in patients with elliptic aortic annulus10.4244/EIJ-D-19-00115 ↗
12. Potential mechanism of annulus rupture during transcatheter aortic valve implantation10.1002/ccd.24524 ↗
13. Reconstruction of stent induced loading forces on the aortic valve complex
14. Incidence and outcome of peri-procedural transcatheter heart valve embolization and migration: the TRAVEL registry (TranscatheteR HeArt Valve EmboLization and Migration)10.1093/eurheartj/ehz429 ↗
15. Stent geometry and radial force comparison of Portico vs CoreValve
16. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery10.1056/NEJMoa1008232 ↗
17. Estimation of in vivo mechanical properties of the aortic wall: a multi-resolution direct search approach
18. Identification of in vivo nonlinear anisotropic mechanical properties of ascending thoracic aortic aneurysm from patient-specific CT scans
19. On the modeling of patient-specific transcatheter aortic valve replacement: a fluid–structure interaction approach10.1007/s13239-019-00427-0 ↗
20. On the modeling of patient-specific transcatheter aortic valve replacement: a fluid–structure interaction approach10.1007/s13239-019-00427-0 ↗
21. Simulation of transcatheter aortic valve implantation through patient-specific finite element analysis: Two clinical cases10.1016/j.jbiomech.2014.06.007 ↗
22. Prediction of patient-specific post-operative outcomes of TAVI procedure: the impact of the positioning strategy on valve performance10.1016/j.jbiomech.2015.10.048 ↗
23. Neragi-Miandoab · 2013
24. Computational analysis of self-expanding and balloon-expandable Transcatheter heart valves10.3390/biomechanics1010004 ↗
25. Pasta · 2020 · 1
26. Surgical or transcatheter aortic-valve replacement in intermediate-risk patients10.1056/NEJMoa1700456 ↗
27. July). Simulation of transcatheter aortic valve implantation under consideration of leaflet calcification
28. Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI)10.1016/j.medengphy.2012.04.009 ↗
29. New conduction abnormalities after TAVI—frequency and causes10.1038/nrcardio.2012.58 ↗
30. Immersogeometric fluid–structure interaction modeling and simulation of transcatheter aortic valve replacement10.1016/j.cma.2019.07.025 ↗
31. Numerical models of valve-in-valve implantation: effect of intentional leaflet laceration on the anchorage10.1007/s10237-019-01218-1 ↗