Thermal oxidation of medical Ti6Al4V blasted with ceramic particles: Effects on the microstructure, residual stresses and mechanical properties
Source abstract
Abstract
Roughening of Ti6Al4V by blasting with alumina or zirconia particles improves the mechanical fixation of implants by increasing the surface area available for bone/implant apposition. Additional thermal oxidation treatments of the blasted alloy have already shown to be a complementary low-cost solution to enhancing the in vitro biocompatibility and corrosion resistance of the alloy. In this work, the effects of oxidation treatment on a grit blasted Ti6Al4V biomedical alloy have been analysed in order to understand the net effect of the combined treatments on the alloy fatigue properties. Synchrotron radiation diffraction experiments have been performed to measure residual stresses before and after the treatments and microstructural and hardness changes have been determined. Although blasting of Ti6Al4V with small spherical zirconia particles increases the alloy fatigue resistance with respect to unblasted specimens, fatigue strength after oxidation decreases below the unblasted value, irrespective of the type of particle used for blasting. Moreover, at 700°C the as-blasted compressive residual stresses (700MPa) are not only fully relaxed but even moderate tensile residual stresses, of about 120MPa, are found beneath the blasted surfaces. Contrary to expectations, a moderate increase in hardness occurs towards the blasted surface after oxidation treatments. This can be attributed to the fact that grit blasting modifies the crystallographic texture of the Ti6Al4V shifting it to a random texture, which affects the hardness values as shown by additional experiments on cold rolled samples. The results indicate that the oxidation treatment performed to improve biocompatibility and corrosion resistance of grit blasted Ti6Al4V should be carried out with caution since the alloy fatigue strength can be critically diminished below the value required for high load-bearing components.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · High-Velocity Impact and Material Behavior · Surface Treatment and Residual Stress
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (42)
Show source-provided references
1. Effect of electropulsing treatment and ultrasonic striking treatment on the mechanical properties and microstructure of biomedical Ti–6Al–4V alloy10.1016/j.jmbbm.2014.08.022 ↗
2. Enhanced grain refinement and microhardness of Ti–Al–V alloy by electropulsing ultrasonic shock10.1016/j.jallcom.2014.09.192 ↗
3. Investigation on the surface and near-surface characteristics of Ti–2.5Cu after various mechanical surface treatments10.1016/j.surfcoat.2011.01.001 ↗
4. Bone tissue response to commercially pure titanium implants blasted with fine and coarse particles of aluminum oxide
5. Osseointegration of grit blasted and bioactive titanium implants: histomorphometry in minipigs10.4028/www.scientific.net/KEM.254-256.737 ↗
6. Comparison between shot peening and surface nanocrystallization and hardening processes10.1016/j.msea.2006.07.159 ↗
7. Effect of cryogenic treatment on wear resistance of Ti–6Al–4V alloy for biomedical applications10.1016/j.jmbbm.2013.11.003 ↗
8. Cyclic deformation and near surface microstructures of shot peened or deep rolled austenitic stainless steel AISI 30410.1016/S0921-5093(98)01121-6 ↗
9. Surface spectroscopic characterization of titanium implant materials10.1016/0368-2048(95)02530-8 ↗
10. Concentration-dependent effects of titanium and aluminium ions released from thermally oxidized Ti6Al4V alloy on human osteoblasts10.1002/jbm.a.30599 ↗
11. Surface modification of titanium alloy implants10.1016/0142-9612(94)90113-9 ↗
12. 3D, chemical and electrochemical characterization of blasted Ti6Al4V surfaces: its influence on the corrosion behaviour10.1016/j.electacta.2006.12.031 ↗
13. In vitro corrosion behaviour and osteoblast responses of thermally oxidised Ti6Al4V alloy10.1016/S0142-9612(02)00237-5 ↗
14. Osteoblast response to thermally oxidised Ti6Al4V alloy10.1002/jbm.a.30264 ↗
15. Thermal oxidation enhances early interactions between human osteoblasts and alumina blasted Ti6Al4V alloy10.1002/jbm.a.30994 ↗
16. Influence of the microstructure and topography on the barrier properties of oxide scales generated on blasted Ti6Al4V surfaces10.1016/j.actbio.2011.02.040 ↗
17. Characterization of roughness and pitting corrosion of surfaces modified by blasting and thermal oxidation10.1016/j.surfcoat.2010.04.051 ↗
18. Fatigue behavior of Ti6Al4V and 316 LVM blasted with ceramic particles of interest for medical devices10.1016/j.jmbbm.2013.10.013 ↗
19. Residual stresses
20. Influencia del arenado de la aleación Ti6Al4V en la dureza subsuperficial y estado de tensiones residuales10.3989/revmetalm.0803 ↗
21. Improvement of the blasting induced effects on medical 316 LVM stainless steel by short-term thermal treatments10.1016/j.surfcoat.2014.07.027 ↗
22. On the influence of mechanical surface treatments—deep rolling and laser shock peening—on the fatigue behavior of Ti–6Al–4V at ambient and elevated temperatures10.1016/S0921-5093(03)00069-8 ↗
23. Interrogations on the sub-surface strain hardening of grit blasted Ti–6Al–4V alloy10.1016/j.surfcoat.2009.02.003 ↗
24. Noyan · 1987
25. Application of energy-dispersive diffraction to the analysis of multiaxial residual stress fields in the intermediate zone between surface and volume10.1016/j.msea.2003.09.073 ↗
26. Mechanical assessment of grit blasting surface treatments of dental implants10.1016/j.jmbbm.2014.07.027 ↗
27. Anodización del titanio para la mejora ante la degradación química de material quirúrgico10.5821/sibb.v12i1.1712 ↗
28. Titanium and titanium alloys—from raw material to semi-finished products10.1002/adem.200310092 ↗
29. General relation between tensile strength and fatigue strength of metallic materials10.1016/j.msea.2012.11.103 ↗
30. Formation of a submicrocrystalline structure in a two-phase titanium alloy without severe plastic deformation10.1016/j.scriptamat.2013.02.055 ↗
31. Enhancement of fatigue and corrosion properties of pure Ti by sandblasting10.1016/j.msea.2006.04.024 ↗
32. Mechanical, electrochemical and tribological properties of nano-crystalline surface of 304 stainless steel10.1016/S0043-1648(03)00055-3 ↗
33. Oxygen diffusion for the deep-case hardening of titanium alloys10.1016/S0921-5093(99)00697-8 ↗
34. The effect of treatment condition on boost diffusion of thermally oxidized titanium alloy10.1016/j.jallcom.2006.05.045 ↗
35. Titanium alloys for biomedical applications10.1016/j.msec.2005.08.032 ↗
36. Hardness versus strength correlation for oxygen-strengthened Ti–6Al–4V alloy10.1016/0956-716X(91)90335-X ↗
37. Surface modification of Ti–6Al–4V alloys using triode plasma oxidation treatments10.1016/j.surfcoat.2012.05.001 ↗
38. Titanium alloys for biomedical applications10.1016/j.msec.2005.08.032 ↗
39. The effect of hot rolling condition on the anisotropy of mechanical properties in Ti–6Al–4V alloy10.1016/j.msea.2006.02.313 ↗
40. Influence of processing on microstructure and mechanical properties of (α+β) titanium alloys10.1016/S0921-5093(97)00778-8 ↗
41. Significance of the contacting and no contacting thermoelectric power measurements applied to grit blasted medical Ti6Al4V10.1016/j.msec.2012.12.045 ↗
42. Macro and micro-residual stress distribution in 6061 Al–15vol% SiCw under different heat treatment conditions10.1016/j.compscitech.2005.11.006 ↗