Time-elapsed synchrotron-light microstructural imaging of femoral neck fracture
Source abstract
Abstract
Time-elapsed micro-computed-tomography (μCT) imaging allows studying bone micromechanics. However, no study has yet performed time-elapsed μCT imaging of human femoral neck fractures. We developed a protocol for time-elapsed synchrotron μCT imaging of the microstructure in the entire proximal femur, while inducing clinically-relevant femoral neck fractures. Three human cadaver femora (females, age: 75-80 years) were used. The specimen-specific force to be applied at each load step was based on the specimens' strength estimated a priori using finite-element analysis of clinical CT images. A radio-transparent compressive stage was designed for loading the specimens while recording the applied load during synchrotron μCT scanning. The total μCT scanning field of view was 146 mm wide and 131 mm high, at 29.81 µm isotropic pixel size. Specimens were first scanned unloaded, then under incremental load steps, each equal to 25% of the estimated specimens' strength, and ultimately after fracture. Fracture occurred after 4-5 time-elapsed load steps, displaying sub-capital fracturing of the femoral neck, in agreement with finite-element predictions. Time-elapsed μCT images, co-registered to those of the intact specimen, displayed the proximal femur microstructure under progressive deformation up to fracture. The images showed (1) a spatially heterogeneous deformation localized in the proximal femoral head; (2) a predominantly elastic recovery, after load removal, of the diaphyseal and trochanteric regions and; (3) post-fracture residual displacements, mainly localized in the fractured region. The time-elapsed μCT imaging protocol developed and the high resolution images generated, made publicly available, may spur further research into human femur micromechanics and fracture.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Bone health and osteoporosis research · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (33)
Show source-provided references
1. Comparison of explicit finite element and mechanical simulation of the proximal femur during dynamic drop-tower testing10.1016/j.jbiomech.2014.11.042 ↗
2. An innovative CCD-based high-resolution CT system for analysis of trabecular bone tissue10.1109/TNS.2006.876047 ↗
3. In-vitro method for assessing femoral implant-bone micromotions in resurfacing hip implants under different loading conditions10.1243/09544119JEIM278 ↗
4. Epidemiology and outcomes of osteoporotic fractures10.1016/S0140-6736(02)08657-9 ↗
5. Multiple loading conditions analysis can improve the association between finite element bone strength estimates and proximal femur fractures: a preliminary study in elderly women10.1016/j.bone.2014.06.038 ↗
6. Morphometric evaluation of proximal femur in patients with unilateral total hip prosthesis10.1002/ca.22245 ↗
7. Quantitative, 3D visualization of the initiation and progression of vertebral fractures under compression and anterior flexion10.1002/jbmr.2749 ↗
8. Risk of hip fracture according to the world health organization criteria for osteopenia and osteoporosis10.1016/S8756-3282(00)00381-1 ↗
9. Comparison of QCT-derived and DXA-derived areal bone mineral density and T scores10.1007/s00198-008-0820-y ↗
10. Martelli, S., Perilli, E., 2016. Time-Lapsed Microstructural Images of Femoral Neck Fractures in Elderly Caucasian Women. 〈http://dx.doi.org/10.4226/86/592680cb25f8b〉.
11. Cortical and trabecular load sharing in the human femoral neck10.1016/j.jbiomech.2014.12.022 ↗
12. Microstructural failure mechanisms in the human proximal femur for sideways fall loading10.1002/jbmr.2033 ↗
13. The interaction of microstructure and volume fraction in predicting failure in cancellous bone10.1016/j.bone.2006.06.013 ↗
14. High-resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone10.1016/S0021-9290(00)00149-4 ↗
15. Effect of boundary conditions on yield properties of human femoral trabecular bone10.1007/s10237-015-0741-6 ↗
16. Pauwel, F., 1934. Der Schenkenholsbruck em mechanisches problem, Gd. Des Heilungsvorganges Progn. Und Kausale Ther. Stuttgart, Ger. Ferdinand Engke.
17. MicroCT examination of human bone specimens: effects of polymethylmethacrylate embedding on structural parameters10.1111/j.1365-2818.2007.01731.x ↗
18. Dependence of mechanical compressive strength on local variations in microarchitecture in cancellous bone of proximal human femur10.1016/j.jbiomech.2007.08.003 ↗
19. Failure strength of human vertebrae: prediction using bone mineral density measured by DXA and bone volume by micro-CT10.1016/j.bone.2012.03.002 ↗
20. Micro-CT examination of human bone: from biopsies towards the entire organ
21. Micro-CT examinations of trabecular bone samples at different resolutions: 14, 7 and 2 μm level10.3233/THC-1998-65-611 ↗
22. Application of the digital volume correlation technique for the measurement of displacement and strain fields in bone: a literature review10.1016/j.jbiomech.2014.01.001 ↗
23. Ruedi · 2000
24. Stress relaxation in native and EDTA-treated bone as a function of mineral content10.1016/0021-9290(93)90615-L ↗
25. Stress relaxation function of bone and bone collagen10.1016/0021-9290(93)90088-V ↗
26. To what extent can linear finite element models of human femora predict failure under stance and fall loading configurations?10.1016/j.jbiomech.2014.08.024 ↗
27. Consequences of a hip fracture: a prospective study over 1 year10.1007/BF01623276 ↗
28. Mechanical properties of single bovine trabeculae are unaffected by strain rate10.1016/j.jbiomech.2010.12.008 ↗
29. The micro-structure of bone trabecular fracture: an inter-site study10.1016/j.bone.2013.12.007 ↗
30. Development of a surrogate model based on patient weight, bone mass and geometry to predict femoral neck strains and fracture loads10.1016/j.jbiomech.2017.02.022 ↗
31. Time-lapsed investigation of three-dimensional failure and damage accumulation in trabecular bone using synchrotron light10.1016/j.bone.2006.01.147 ↗
32. Trabecular bone tissue strains in the healthy and osteoporotic human femur10.1359/jbmr.2003.18.10.1781 ↗
33. Strain distribution in the proximal human femur during in vitro simulated sideways fall10.1016/j.jbiomech.2015.02.022 ↗