journal article·2016-01

Effects of gamma and e-beam sterilization on the chemical, mechanical and tribological properties of a novel hydrogel

Mariya Tohfafarosh, Doruk Baykal, Jonathan W. Kiel, Kevin Mansmann, Steven M. Kurtz

Publisher page

Abstract

Hydrogels are known to possess cartilage-like mechanical and lubrication properties; however, hydrogel sterilization is challenging. Cyborgel(™), a proprietary hydrogel, is intended for use as a cartilage replacement implant. This study evaluated the effect of 30-35 kGy e-beam and gamma radiation on the polymer swell ratio, and the mechanical, chemical and tribological behavior of this hydrogel. Three different formulations were mechanically tested, and material parameters were identified using finite element analysis. FTIR spectroscopy was used to investigate chemical changes. Wear test was carried out for 2 million cycles in bovine serum, followed by 2 million cycles in distilled water. No significant difference was found in the swell ratio, mechanical and tribological properties of control hydrogel samples and those exposed to e-beam or gamma radiation; however, chemical spectra of e-beam sterilized samples revealed minor changes, which were absent in unsterilized and gamma sterilized samples.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Osteoarthritis Treatment and Mechanisms · Total Knee Arthroplasty Outcomes · Knee injuries and reconstruction techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (32)

Show source-provided references
1. Composite hydrogels for implants10.1243/0954411981533863 ↗
2. Tribological evaluation of hydrogel articulations for joint arthroplasty applications10.1016/j.jmbbm.2012.05.012 ↗
3. Evaluation of friction properties of hydrogels based on a biphasic cartilage model10.1016/j.jmbbm.2013.07.022 ↗
4. Biomechanical properties of human articular cartilage under compressive loads
5. FT-IR imaging of native and tissue-engineered bone and cartilage10.1016/j.biomaterials.2006.11.043 ↗
6. Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt–chromium modular neck10.2106/JBJS.L.01042 ↗
7. Factors determining hydrogel permeability10.1111/j.1749-6632.1997.tb52194.x ↗
8. Lubrication mode analysis of articular cartilage using Stribeck surfaces10.1016/j.jbiomech.2008.03.043 ↗
9. Effects of sterilization on poly(ethylene glycol) hydrogels10.1002/jbm.a.31811 ↗
10. Characterization of a polyvinyl alcohol-hydrogel artificial articular cartilage prepared by injection molding10.1163/156856204774196135 ↗
11. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 203010.2106/00004623-200704000-00012 ↗
12. Kurtz · 2004 · 379
13. Kurtz · 2009
14. Effect of gamma-irradiation on degradation of alginate10.1021/jf021053y ↗
15. Inverse analysis of constitutive models: biological soft tissues10.1016/j.jbiomech.2006.03.014 ↗
16. Mechanical characterization of soft viscoelastic gels via indentation and optimization-based inverse finite element analysis10.1016/j.jmbbm.2008.12.001 ↗
17. FEBio: finite elements for biomechanics10.1115/1.4005694 ↗
18. An arthroscopic device to assess articular cartilage defects and treatment with a hydrogel10.1007/s10439-010-0209-x ↗
19. Biphasic creep and stress relaxation of articular cartilage in compression? Theory and experiments10.1115/1.3138202 ↗
20. Trends in biological joint resurfacing10.1302/2046-3758.29.2000189 ↗
21. Development of artificial articular cartilage10.1243/0954411001535246 ↗
22. A dual optimization method for the material parameter identification of a biphasic poroviscoelastic hydrogel: potential application to hypercompliant soft tissues10.1016/j.jbiomech.2005.07.019 ↗
23. The direct and indirect costs to society of treatment for end-stage knee osteoarthritis10.2106/JBJS.L.01488 ↗
24. 5 to 8 years follow-up of knee chondral defects treated by PVA-H hydrogel implants
25. The biphasic poroviscoelastic behavior of articular cartilage: role of the surface zone in governing the compressive behavior10.1016/0021-9290(93)90019-B ↗
26. Sterilization methods and the comparison of e-beam sterilization with gamma radiation sterilization
27. Knee resurfacing: an alternative to traditional knee replacement
28. A Conewise Linear Elasticity mixture model for the analysis of tension-compression nonlinearity in articular cartilage10.1115/1.1324669 ↗
29. Hydrogels for the repair of articular cartilage defects10.1089/ten.teb.2011.0077 ↗
30. Stuart · 2004 · 224
31. Biotribology properties of natural swine joint cartilage
32. Estimating the effective Young’s modulus of soft tissues from indentation tests--nonlinear finite element analysis of effects of friction and large deformation10.1016/S1350-4533(97)00017-9 ↗