journal article·2012-12

Silicon nitride films for the protective functional coating: Blood compatibility and biomechanical property study

Zhifeng Shi, Yingjun Wang, Chang Du, Nan Huang, Lin Wang, Chengyun Ning

Publisher page

Abstract

Behaviors of silicon nitride films and their relation to blood compatibility and biomechanical have been interesting subjects to researchers. A systematic blood compatibility and biomechanical property investigation on the deposition of silicon-nitride films under varying N₂ and CF₄ flows was carried out by direct current unbalanced magnetron sputtering techniques. Significant role of surface property, chemical bonding state of silicon nitride film and blood compatibility, mechanical properties for the films were observed. The chemical bonding configurations, surface topography, contact angle and mechanical properties were characterized by means of X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM) and nano-indentation technique and CSEM pin-on-disk tribometer. Blood compatibility of the films was evaluated by platelet adhesion investigation. The results of the platelet adhesion tests shown that the effect of fluorine and nitrogen-doped revealed an intimate relationship between the ratio of polar component and dispersion component of the surface energy and its hemocompatibility. Si-N-O coating can be a great candidate for developing antithrombogenic surfaces in blood contacting materials. The chemical bonding state made an adjustment in microstructured surfaces, once in the totally wettable configuration, may improve the initial contact between platelet and biomedical materials, due to the appropriate ratio of dispersion component and polar component. To resist wear, biomedical components require coatings that are tough and hard, have low friction, and are bio-inert. The study suggests that by Si-N coating the metal surfaces could be a choice to prolong the life of the sliding pair Co-Cr-Mo alloy/UHMWPE implants.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Metal and Thin Film Mechanics · Diamond and Carbon-based Materials Research · Tribology and Wear Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (46)

Show source-provided references
1. Chemical treatment effect of Si (111) surfaces in F-based aqueous solutions10.1063/1.362729 ↗
2. Behavior of cultured human umbilical vein endothelial cells on titanium oxide films fabricated by plasma immersion ion implantation and deposition10.1016/j.surfcoat.2004.02.050 ↗
3. Dean · 2003 · 05
4. Effect of nitrogen plasma-based ion implantation on joint prosthetic material
5. Fandino · Journal of Vacuum Science & Technology A · 2005 · 23 · 24810.1116/1.1854693 ↗
6. Glutardialdehyde induced fluorescence technique (GIFT): a new method for the imaging of platelet adhesion on biomaterials10.1002/1097-4636(200011)52:2<374::AID-JBM18>3.0.CO;2-Z ↗
7. The investigation of properties of silicon nitride films obtained by RPECVD from hexamethyldisilazane10.1016/S0169-4332(96)00825-2 ↗
8. Electrical properties of silicon nitride films plasma–deposited from SiF4, N2, and H2 source gases10.1063/1.334768 ↗
9. Gopel · 1998
10. Friction and wear behavior of nitrogen ion implanted UHMWPE against ZrO2 ceramic10.1016/S0043-1648(03)00269-2 ↗
11. A review of modified DLC coatings for biological applications10.1016/S0925-9635(03)00081-5 ↗
12. Thermal stability of carbon nitride thin films10.1557/JMR.2001.0440 ↗
13. Fluorine doping into diamond-like carbon coatings inhibits protein adsorption and platelet activation10.1002/jbm.a.31340 ↗
14. Huang, N., Yang, P., Leng, Y.X., Wang, J., Chen, J.Y., Sun, H., 2004. Surface modification for controlling the blood–materials interface. In: The Sixth Asia Symposium on Biomaterials, July 20–23, Chengdu, China.
15. Cobalt and chromium concentrations in patients with metal on metal total hip replacements10.1097/00003086-199608001-00022 ↗
16. Composition, oxidation, and optical properties of fluorinated silicon nitride film by inductively coupled plasma enhanced chemical vapor deposition10.1557/JMR.1999.0133 ↗
17. Protein adsorption and platelet attachment and activation, on TiN, TiC, and DLC coatings on titanium for cardiovascular applications10.1002/1097-4636(200011)52:2<413::AID-JBM23>3.0.CO;2-U ↗
18. Surface energy, wettability, and blood compatibility phosphorus doped diamond-like carbon films10.1016/j.diamond.2004.07.019 ↗
19. Dynamics of hydrated polyurethane biomaterials: surface microphase restructuring, protein activity and platelet adhesion10.1016/j.actbio.2009.11.031 ↗
20. Prediction of new low compressibility solid10.1126/science.245.4920.841 ↗
21. Towards the deposition of tetrahedral diamond-like carbon films on hip joints by femtosecond pulsed laser ablation10.1016/j.surfcoat.2004.07.046 ↗
22. Biofilm formation on bone grafts and bone graft substitutes: comparison of different materials by a standard in vitro test and microcalorimetry10.1016/j.actbio.2010.03.011 ↗
23. Haemocompatibility evaluation of DLC- and SiC-coated surfaces10.22203/eCM.v005a02 ↗
24. Platelet adhesion on silicon modified hydrogenated amorphous carbon films10.1016/S0142-9612(03)00494-0 ↗
25. Otha · Journal of Applied Physics · 2001 · 90 · 195510.1063/1.1381556 ↗
26. Measurement of hardness and elastic modulus by instrumented indentation: advances in understanding and refinements to methodology10.1557/jmr.2004.19.1.3 ↗
27. Software-supported image quantification of angiogenesis in an in vitro culture system: application to studies of biocompatibility10.1016/S0142-9612(02)00042-X ↗
28. Biomedical applications of diamond-like carbon coatings: a review10.1002/jbm.b.30768 ↗
29. Hemocompatibility of surface-modified, silicon-incorporated, diamond-like carbon films10.1016/j.actbio.2008.07.031 ↗
30. Structure and properties of pulsed-laser deposited carbon nitride thin films10.1016/j.tsf.2005.09.172 ↗
31. Antithrombogenicity of fluorinated diamond-like carbon films10.1016/j.diamond.2004.09.017 ↗
32. Tribological characterisation of diamond-like carbon coatings on Co–Cr–Mo alloy for orthopaedic applications10.1016/S0257-8972(01)01425-6 ↗
33. Modification of diamond-like carbon coatings with fluorine to reduce bio-fouling adhesion10.1016/j.surfcoat.2010.01.022 ↗
34. Tribological performance of some alternative bearing materials for artificial joints10.1016/S0043-1648(03)00276-X ↗
35. Tribological characterization of surface modified UHMWPE against DLC-coated Co–Cr–Mo10.1016/j.surfcoat.2004.02.051 ↗
36. Cell adhesion to plasma-treated polymer surfaces10.1016/0032-3861(93)90752-V ↗
37. Amorphous carbon as a bio-mechanical coating-mechanical properties and biological applications10.1016/S0925-9635(00)00462-3 ↗
38. Biocompatibility of diamond-like carbon coating10.1016/0142-9612(91)90129-X ↗
39. Diamond-like carbon coating and plasma or glow discharge treatment of mechanical heart valves10.1080/089419399272520 ↗
40. Biocompatibility of diamond-like carbon coating10.1016/0142-9612(91)90129-X ↗
41. The effects of amorphous carbon films deposited on polyethylene terephthalate on bacterial adhesion10.1016/j.biomaterials.2003.10.010 ↗
42. Blood compatibilities of carbon nitride film deposited on biomedical NiTi alloy10.1016/j.diamond.2009.07.003 ↗
43. Wan, G.J., Huang, N., Yang, P., Ricky, K.Y., Fu, Ho, Joan, P.Y., Xie, X., Zhou H.F., Chu Paul K., 2007. Platelet activation behavior on nitrogen plasma-implanted silicon. Materials Science and Engineering C27, 928–93210.1016/j.msec.2006.11.005 ↗
44. Immobilization of bovine serum albumin on TiO2 film via chemisorption of H3PO4 interface and effects on platelets adhesion10.1016/j.apsusc.2007.10.107 ↗
45. Activation of platelets adhered on amorphous hydrogenated carbon (a-C:H) films synthesized by plasma immersion ion implantation-deposition (PIII-D)10.1016/S0142-9612(03)00091-7 ↗
46. Effects of negative low substrate bias voltage on the structure and properties of fluorinated amorphous carbon films synthesized by plasma immersion ion implantation and deposition10.1016/j.surfcoat.2004.04.038 ↗