journal article·2014-12

Galvanically enhanced fretting-crevice corrosion of cemented femoral stems

M. Bryant, R. Farrar, R. Freeman, K. Brummitt, J. Nolan, A. Neville

Publisher page

Abstract

The Ultima TPS MoM THR was designed and developed as a 2nd generation MoM THR specifically aimed at younger more active patients due to the anticipated low wear rates and increased longevity of MoM THRs. In 2010, published clinical data highlighted the early failure of the Ultima TPS MoM due to fretting-crevice corrosion at the stem-cement interface. Since 2010 similar observations have been reported by other clinical centres implicating competitor products as well as the Ultima TPS MoM THR. In an attempt to replicate the electrochemical reaction and interactions established across MoM THR systems, fretting-crevice corrosion tests subjected to galvanic coupling were conducted. Galvanic coupling was seen to significantly increase the rates of corrosion under static and dynamic conditions. This was due to the large potential differences developed across the system between active and passive areas, increasing the rates of corrosion and metallic ion release from the stem-cement interface.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Cardiac Structural Anomalies and Repair

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. Effect of femoral head size on the wear of metal on metal bearings in total hip replacements under adverse edge-loading conditions10.1002/jbm.b.32824 ↗
2. What results in fretting wear on polished femoral stems10.1016/j.triboint.2008.11.007 ↗
3. What results in fretting wear on polished femoral stems10.1016/j.triboint.2008.11.007 ↗
4. High failure rates with a large-diameter hybrid metal-on-metal total hip replacement: clinical, radiological and retrieval analysis10.1302/0301-620X.93B5.26309 ↗
5. Brown, L., Zhang, H., Blunt, L., Barrans, S., 2007. Reproduction of fretting wear at the stem-cement interface in total hip replacement. In: Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine 221, Nov.10.1243/09544119JEIM333 ↗
6. Fretting corrosion of fully cemented polished collarless tapered stems: the influence of PMMA bone cement10.1016/j.wear.2012.12.042 ↗
7. Fretting corrosion characteristics of polished collarless tapered stems in a simulated biological environment10.1016/j.triboint.2013.01.024 ↗
8. Fretting corrosion characteristics of polished collarless tapered stems in a simulated biological environment10.1016/j.triboint.2013.01.024 ↗
9. Characterisation of the surface topography, tomography and chemistry of fretting corrosion product found on retrieved polished femoral stems10.1016/j.jmbbm.2013.11.016 ↗
10. Failure analysis of cemented metal-on-metal total hip replacements from a single centre cohort10.1016/j.wear.2012.12.013 ↗
11. Clinical and radiological results of the collarless polished tapered stem at 15 years follow-up10.1302/0301-620X.94B7.28799 ↗
12. Early failure of the Ultima metal-on-metal total hip replacement in the presence of normal plain radiographs10.1302/0301-620X.92B11.24504 ↗
13. PRESIDENTIAL GUEST LECTURE: tribology of alternative bearings10.1097/01.blo.0000238871.07604.49 ↗
14. Fretting-corrosion of materials used as orthopaedic implants10.1016/j.wear.2004.11.027 ↗
15. Modeling fretting-corrosion wear of 316L SS against poly(methyl methacrylate) with the Point Defect Model: fundamental theory, assessment, and outlook10.1016/j.electacta.2012.06.028 ↗
16. Assessing the tribocorrosion behaviour of Cu and Al by electrochemical impedance spectroscopy10.1016/j.triboint.2010.04.018 ↗
17. In vitro corrosion testing of modular hip tapers10.1002/jbm.b.10526 ↗
18. Mechanical and chemical mechanisms in the tribocorrosion of a Stellite type alloy10.1016/j.wear.2013.04.007 ↗
19. Cobalt from metal-on-metal hip replacements may be the clinically relevant active agent responsible for periprosthetic tissue reactions10.1016/j.actbio.2012.05.003 ↗
20. Characterization of the running-in period in total hip resurfacingarthroplasty: an in vivo and in vitro metal ion analysis10.2106/JBJS.H.00437 ↗
21. Biotribocorrosion of metal-on-metal hip replacements: how surface degradation can influence metalion formation10.1016/j.triboint.2013.02.025 ↗
22. In vivo surface wear mechanisms of femoral components of cemented total hip arthroplasties10.1016/S0883-5403(03)00278-X ↗
23. In vivo surface wear mechanisms of femoral components of cemented total hip arthroplasties: the influence of wear mechanism on clinical outcome10.1016/S0883-5403(03)00278-X ↗
24. Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study10.2106/00004623-199810000-00006 ↗
25. Electrochemical methods in tribocorrosion: a critical appraisal10.1016/S0013-4686(01)00679-X ↗
26. The relationship between galvanic current and dissolution rates10.5006/0010-9312-29.10.403 ↗
27. Triboelectrochemical techniques and interpretation methods in tribocorrosion: a comparative evaluation10.1016/j.triboint.2007.11.003 ↗
28. Wear of CoCrMo alloys used in metal-on-metal hip joints: a tribocorrosion appraisal10.1016/j.wear.2012.11.061 ↗
29. Influence of passivity on the tribocorrosion of carbon steel in aqueous solutions10.1016/S0043-1648(01)00754-2 ↗
30. National Joint Registry, 2012. National Joint Registry for England and Wales: 9th Annual Report 2012, 〈http://www.njrcentre.org.uk/NjrCentre/LinkClick.aspx?fileticket=QkPI7kk6B2E%3d&tabid=86&mid=52〉.
31. Electrochemical simulation of the current and potential response in sliding tribocorrosion10.1007/s11249-012-0022-9 ↗
32. Triple tapered cemented polished stem in total hip arthroplasty. A review of 1008 cases using the c-stem with a minimum of 5 years clinical and radiological follow-up
33. Reynolds · 2006
34. Alternative materials to improve total hip replacement tribology
35. Exeter versus Ultima-TPS femoral stem: a randomised early outcomes study
36. Clinical and radiological outcome of total hip replacement five years after pamidronate therapy
37. Stack, M.M., Chi, K., 2003. Mapping sliding wear of steels in aqueous conditions. In: Proceedings of the Wear 14th International Conference on Wear of Materials, pp. 456–465.10.1016/S0043-1648(03)00203-5 ↗
38. WHO, 2014. Musculoskeletal conditions affect millions. Available at: http://www.who.int/mediacentre/news/releases/2003/pr81/en/ (accessed 17.09.2014)
39. The contribution of the micropores in bone cement surface to generation of femoral stem wear in total hip replacement10.1016/j.triboint.2010.11.007 ↗