journal article·2018-06

Variation of mechanical properties and oxidation with radiation dose and source in highly crosslinked remelted UHMWPE

Mitchell Fung, John G. Bowsher, Douglas W. Van Citters

Publisher page

Abstract

Ultra-high molecular weight polyethylene (UHMWPE) is the current gold standard for bearing materials used in total joint arthroplasty. High-dose radiation is commonly used to crosslink UHMWPE, thereby improving its wear resistance. A subsequent remelting step eliminates trapped residual free radicals to promote oxidative stability on the shelf, and to prevent material degradation over the long term. Assessment of clinically retrieved, highly crosslinked UHMWPE devices shows signs of unanticipated oxidation occurring in vivo, despite the absence of free radicals prior to implantation. These findings warrant further investigation into possible factors impacting this phenomenon along with its clinical implications. The overall objective of this work is to quantify the influence of irradiation dose and source on UHMWPE's oxidative stability, along with the effects of oxidation on the ultimate mechanical properties, including strength, ductility, and toughness. The results showed a strong positive correlation between maximum oxidation and initial transvinylene content. Critical oxidation levels in the context of mechanical property loss were determined for e-beam and gamma treatments at various radiation doses. Further, it was shown that critical oxidation was more dependent on radiation dose and less dependent on source. If in vivo oxidation persists in these devices, this can potentially lead to mechanical failure (e.g. fatigue damage) as observed in terminally gamma-sterilized devices.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Orthopedic Infections and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (50)

Show source-provided references
1. ASTM · 2000
2. Gamma-irradiation sterilization in an inert environment a partial solution10.1007/s11999-011-2150-1 ↗
3. The effects of shelf life on clinical outcome for gamma sterilized polyethylene tibial components
4. Effects of vinyl chain-ends on the melt viscoelastic properties of radiation crosslinked polyethylene10.1177/875608799200800105 ↗
5. Comparison of cross-linked polyethylene materials for orthopaedic applications10.1097/01.blo.0000073343.50837.03 ↗
6. Polyethylene debris-induced osteolysis and loosening in uncemented total hip arthroplasty. A cause of late failure10.1016/0883-5403(92)90050-Z ↗
7. Post electron-beam irradiation oxidation of orthopaedic ultra-high molecular weight polyethylene (UHMWPE) stabilized with vitamin E10.1016/j.polymdegradstab.2009.04.023 ↗
8. Oxidation in orthopaedic UHMWPE sterilized by gamma-radiation and ethylene oxide10.1016/S0142-9612(97)00160-9 ↗
9. Effect of fabrication method and resin type on performance of tibial bearings10.1002/(SICI)1097-4636(2000)53:2<143::AID-JBM3>3.0.CO;2-5 ↗
10. Shelf life and in vivo duration. impacts on performance of tibial bearings
11. In vivo oxidation of γ-barrier-sterilized ultra-high-molecular-weight polyethylene bearings10.1016/j.arth.2006.07.006 ↗
12. In vivo oxidation in retrieved highly crosslinked tibial inserts10.1002/jbm.b.32805 ↗
13. In vivo oxidation in remelted highly cross-linked retrievals10.2106/JBJS.I.01006 ↗
14. A858. Accelerated aging of next generation cross-linked materials: stability concerns?
15. 5-Year experience of highly cross-linked polyethylene in cemented and uncemented sockets: two randomized studies using radiostereometric analysis10.1080/17453670710014518 ↗
16. Irradiation of polyethylene. II. kinetics of unsaturation effects
17. Osteolysis and particle disease in hip replacement. A review10.3109/17453679408993734 ↗
18. Morphology
19. The effect of radiation dose on the tensile and impact toughness of highly cross-linked and remelted ultrahigh-molecular weight polyethylenes10.1002/jbm.b.31818 ↗
20. Free-radical identification by ESR in polyethylene and nylon10.1002/pol.1983.170210824 ↗
21. Clinical reviews: particulate debris and failure of total hip replacements10.1002/jab.770040310 ↗
22. Radiolytic formation and decay of trans-vinylene unsaturation in polyethylene: fourier transform infra-red measurements10.1016/0969-806X(95)00271-X ↗
23. Oxidation of ultra-high molecular weight polyethylene and its influence on contact fatigue and pitting of knee bearings10.1080/10402000308982607 ↗
24. Osteolytic indicators found in total knee arthroplasty synovial fluid aspirates10.1097/00003086-200010000-00022 ↗
25. Comparison of the properties of annealed crosslinked (Crossfire) and conventional polyethylene as hip bearing materials
26. Fracture/dissociation of the polyethylene in metal-backed patellar components in total knee arthroplasty10.2106/00004623-198870050-00006 ↗
27. Radiolytic formation and decay of trans-vinylene unsaturation in polyethylene
28. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements10.1002/jor.1100170203 ↗
29. High-density polyethylene dosimetry by transvinylene FTIR analysis10.1016/S0969-806X(99)00324-2 ↗
30. A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. recipient of the 1999 HAP Paul Award10.1054/arth.2001.20540 ↗
31. Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE)10.1016/S0142-9612(99)00039-3 ↗
32. Identification and quantification of irradiation in UHMWPE through trans-vinylene yield10.1002/1097-4636(20010915)56:4<584::AID-JBM1131>3.0.CO;2-Y ↗
33. Alternate bearing surfaces
34. Effect of radiation, heat, and aging on in vitro wear resistance of polyethylene10.1097/01.blo.0000093004.90435.d1 ↗
35. Long term clinical results of THR. Clinical results of THR of an alumina head with a cross-linked UHMWPE cup
36. Radiation cross-linking in ultra-high molecular weight polyethylene for orthopaedic applications10.1016/j.nimb.2007.08.022 ↗
37. Effects of simulated oxidation on the in vitro wear and mechanical properties of irradiated and melted highly crosslinked UHMWPE
38. Chain folding and free energy density in polymer crystals10.1063/1.1735476 ↗
39. Thermodynamische Stabilitat makromolekularer Kristalle10.1007/BF01337766 ↗
40. Osteolysis after total knee arthroplasty without cement10.2106/00004623-199274060-00007 ↗
41. Gamma sterilization of UHMWPE articular implants: an analysis of the oxidation problem10.1016/0142-9612(95)00349-5 ↗
42. Crosslink density, oxidation and chain scission in retrieved, highly cross-linked UHMWPE tibial bearings10.1016/j.biomaterials.2014.02.019 ↗
43. Fatigue strength of polyethylene after sterilization by gamma irradiation or ethylene oxide
44. Immunopathological response to loose cementless acetabular components10.1302/0301-620X.73B1.1991772 ↗
45. Shinde · Irradiat. Ultrah.- Mol.-Weight Polyethyl. · 1985 · 23 · 1681
46. Irradiation of polyethylene: some aspects of crosslinking and oxidative degradation10.1016/S0969-806X(99)00328-X ↗
47. Failure mechanisms of metal-backed patellar components10.1097/00003086-198811000-00011 ↗
48. Impact of gamma sterilization on clinical performance of polyethylene in the hip10.1097/00003086-199510000-00004 ↗
49. Autoxidation of semicrystalline polyethylene10.1002/pen.760060317 ↗
50. Wear of polyethylene in total joint replacements. Observations from retrieved PCA knee implants