Study on biocompatibility, tribological property and wear debris characterization of ultra-low-wear polyethylene as artificial joint materials
Source abstract
Abstract
Ultra-low-wear polyethylene (ULWPE) is a new type polyethylene made by experts who are from China petrochemical research institute, which is easy to process and implant. Preliminary test showed it was more resistant to wear than that of Ultra-high-molecular weight polyethylene (UHMWPE). The purpose of the research is to study biocompatibility, bio-tribological properties and debris characterization of ULWPE. Cytotoxicity test, hemolysis test, acute/chronic toxicity and muscular implantation test were conducted according to national standard GB/T-16886/ISO-10993 for evaluation requirements of medical surgical implants. We obtained that this novel material had good biocompatibility and biological safety. The wear performance of ULWPE and UHMWPE was evaluated in a pin-on-disc (POD) wear tester within two million cycles and a knee wear simulator within six million cycles. We found that the ULWPE was higher abrasion resistance than the UHMWPE, the wear rate of ULWPE by POD test and knee wear simulator was 0.4 mg/106cycles and (16.9 ± 1.8)mg/106cycles respectively, while that of UHMWPE was 1.8 mg/106cycles and (24.6 ± 2.4)mg/106cycles. The morphology of wear debris is also an important factor to evaluate artificial joint materials, this study showed that the ULWPE wear debris gotten from the simulator had various different shapes, including spherical, block, tear, etc. The morphology of worn surface and wear debris analysis showed that wear mechanisms of ULWPE were adhesion wear, abrasive wear and fatigue wear and other wear forms, which were consistent with that of UHMWPE. Thus we conclude that ULWPE is expected to be a lifetime implantation of artificial joint.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Tribology and Wear Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (42)
Show source-provided references
1. Wear performance of neat and vitamin E blended highly cross-linked PE under severe conditions: the combined effect of accelerated ageing and third body particles during wear test10.1016/j.jmbbm.2016.08.003 ↗
2. Wear distribution detection of knee joint prostheses by means of 3D optical scanners10.3390/ma10040364 ↗
3. ANSI/AAMI. ISO 10993-4:2002/A1: Biological Evaluation Of Medical Devices-Part 4: Selection of Tests For Interactions With. Blood-amendment 1. Arlington, VA, 2006.
4. ANSI/AAMI. ISO 10993-5 Biological Evaluation Of Medical Devices-Part 5:Tests for Cytotoxicity:in Vitro Methods. Arlington, VA.
5. ASTM G99-04a: Standard Test Method for Wear Testing with a Pin-on-Disk Apparatus[S].
6. Standard Test Method for Wear Testing of Polymeric Materials Used in Total Joint Prostheses
7. Polyethylene wear characteristics in vivo and in a knee stimulator10.1002/jbm.10139 ↗
8. Commissioning of a displacement-controlled knee wear simulator and exploration of some issues related to the lubricant10.1177/0954411911406061 ↗
9. Highly antibacterial UHMWPE surfaces by implantation of titanium ions10.1016/j.nimb.2013.11.027 ↗
10. Clinical devices and services: repair shops10.1038/545S21a ↗
11. Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene
12. ISO 14243-2, Implants for Surgery-wear of Total Knee-joint Prostheses-Part 2: Methods of Measurement, 2009.
13. ISO 4288, Surface texture: Profile Method-rules and Procedures for the Assessment of Surface Texture, 1996.
14. ISO 7207-2, Implants for Surgery-components for Partial and Total Knee Joint Prostheses-Part 2.Articulating Surfaces Made of Metal, Ceramic and Plastics Materials, 2011.
15. Wear behavior of carbon nanotube/high density polyethylene composites10.1016/j.mechmat.2009.04.003 ↗
16. Nano-wear mechanism for ultra-high molecular weight polyethylene(uhmwpe)sliding against a model hard asperity
17. Evaluation of the biocompatibility of experimentally manufactured portland cement: an animal study10.4317/jced.51210 ↗
18. Dynamic synergy of graphitic nanoplatelets and multi-walled carbon nanotubes in polyetherimide nanocomposites10.1088/0957-4484/21/10/105702 ↗
19. Cytotoxicity evaluation of unfunctionalized multiwall carbon nanotubes-ultrahigh molecular weight polyethylene nanocomposites10.1002/jbm.a.36168 ↗
20. Rat subcutaneous tissue response to modified Portland cement, a new mineral trioxide aggregate10.1590/S0103-64402009000200004 ↗
21. Biomaterials/tissue interactions: possible solutions to overcome foreign body response10.1208/s12248-010-9175-3 ↗
22. Surface grafting of biocompatible phospholipid polymer MPC provides wear resistance of tibial polyethylene insert in artificial knee joints10.1016/j.joca.2010.05.019 ↗
23. Grafting of poly(2-methacryloyloxyethyl phosphorylcholine) on polyethylene liner in artificial hip joints reduces production of wear particles10.1016/j.jmbbm.2013.03.011 ↗
24. Migration stability of alpha-tocopherol in irradiated UHMWPE10.1016/j.biomaterials.2005.11.001 ↗
25. Evaluation of the in vitro and in vivo biocompatibility of carrageenan-based hydrogels10.1002/jbm.a.35081 ↗
26. In vitro wear of ultrahigh-molecular-weight polyethylene and vitamin E blended highly cross-linked polyethylene in linked, semiconstrained total elbow replacement prostheses10.1016/j.jse.2016.12.066 ↗
27. How do gait frequency and serum-replacement interval affect polyethylene wear in knee-wear simulator tests?10.1007/s10856-014-5271-8 ↗
28. Identification of nanometre-sized ultra-high molecular weight polyethylene wear particles in samples retrieved in vivo10.1302/0301-620X.90B8.20737 ↗
29. Effect of shelf versus accelerated aging of UHMWPE on delamination in knee wear simulation10.1016/j.triboint.2014.01.001 ↗
30. Microscale abrasive wear of polymeric materials10.1016/S0043-1648(03)00106-6 ↗
31. What's next? Alternative materials for articulation in total joint replacement10.1016/j.actbio.2012.03.029 ↗
32. Targeted computational probabilistic corroboration of experimental knee wear simulator: the importance of accounting for variability10.1016/j.medengphy.2010.10.015 ↗
33. Tribology of polyethylene homocomposites10.1016/S0043-1648(97)00233-0 ↗
34. Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators10.1002/jbm.a.30824 ↗
35. Importance of preclinical evaluation of wear in hip implant designs using simulator machines10.1016/j.rbo.2016.07.009 ↗
36. The incidence of perioperative cardiac events after orthopedic surgery: a single institutional experience of cases performed over one year10.1007/s11420-017-9561-9 ↗
37. In vivo oxidation of retrieved cross-linked ultra-high-molecular-weight polyethylene acetabular components with residual free radicals10.1016/j.arth.2005.07.019 ↗
38. On the mechanisms of biocompatibility10.1016/j.biomaterials.2008.04.023 ↗
39. Wear resistance of poly(2-methacryloyloxyethyl phosphorylcholine)-grafted carbon fiber reinforced poly(ether ether ketone) liners against metal and ceramic femoral heads
40. Readmission due to infection following total hip and total knee procedures: a retrospective study10.1097/MD.0000000000007961 ↗
41. Improved wear and mechanical properties of UHMWPE-carbon nanofiber composites through an optimized paraffin-assisted melt-mixing process10.1016/j.compositesb.2010.09.006 ↗
42. Experimental testing of total knee replacements with UHMW-PE inserts: impact of severe wear test conditions10.1007/s10856-015-5470-y ↗