Corrosion and wear behavior of Ti–5Cu-xNb biomedical alloy in simulated body fluid for dental implant applications
Source abstract
Abstract
The present study examined the corrosion and tribological behavior of novel Ti-5Cu-xNb alloy synthesized via powder metallurgy as a new biomedical material in a simulated bodily fluid (SBF) solution. The electrochemical impedance spectroscopy (EIS) study reveals the formation of two protective layers on the surface of alloys during the test. The alloys spontaneously produce a passivating oxide coating on their surfaces, and the breakdown potential (1.14-1.17 V) and re-passivation current density (2.07-3.04 μAcm-2) were observed during the potentiodynamic polarization test. The highest corrosion resistance was observed for the alloy Ti-5Cu-10Nb (icorr = 21.44 nA-cm-2). The SEM and XPS analysis of the corroded surface showed the formation of oxide on the surfaces of the alloys. The samples were tested at 10 N, 15 N, and 20 N loads against the zirconia counterpart to investigate the effect of loading on friction and wear. The lowest coefficient of friction was obtained for Ti-5Cu-5Nb (0.25-0.41) at 20 N loading, while the maximum for Ti-5Cu-10Nb at 15 N load falls in the range of (0.71-0.25). Additionally, they present the wear rate in the range of (5.3 × 10-8-1.45 × 10-6 mm3/mm), in accordance with the change in microstructure and mechanical properties. However, the wear rate increases with the addition of niobium and reaches the maximum for Ti-5Cu-15Nb at 20 N loading condition, but it is relatively deficient compared to commonly used implant material. Therefore, it is suggested that this β-type Ti-5Cu-xNb alloy is a promising candidate, more suitable than the commercially used Ti and Ti-6Al-4V for dental applications.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty · Advanced materials and composites
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (65)
Show source-provided references
1. Wear performance of novel nanostructured Ti-Cu intermetallic alloy as a potential material for biomedical applications10.1016/j.jallcom.2017.01.020 ↗
2. Electrochemical studies on the stability and corrosion resistance of titanium-based implant materials10.1016/S0142-9612(00)00309-4 ↗
3. Comparative study on the corrosion behavior of Ti-Nb and TMA alloys for dental application in various artificial solutions10.1016/j.msec.2010.12.010 ↗
4. In vitro and in vivo comparative colonization of Staphylococcus aureus and Staphylococcus epidermidis on orthopaedic implant materials10.1016/0142-9612(89)90073-2 ↗
5. Concentration-dependent cytotoxicity of copper ions on mouse fibroblasts in vitro: effects of copper ion release from TCu380A vs TCu220C intra-uterine devices10.1007/s10544-012-9651-x ↗
6. Novel Ti-Nb alloys with improved wear resistance for biomedical implant application
7. Studying the effect of composition on the in vitro wear behavior and elastic modulus of titanium-niobium-based alloys for biomedical implants10.1088/2057-1976/aa9f78 ↗
8. Tribological behaviour of Ti-based alloys in simulated body fluid solution at fretting contacts10.1016/j.msea.2004.02.027 ↗
9. Electrochemical corrosion behavior of a Ti-35Nb alloy for medical prostheses10.1016/j.electacta.2008.02.011 ↗
10. Corrosion characterization of titanium alloys by electrochemical techniques10.1016/j.electacta.2005.02.121 ↗
11. Microstructure, mechanical properties, and sliding wear behavior of spark plasma sintered Ti-Cu alloys10.1007/s11661-018-4953-0 ↗
12. Dry sliding and tribocorrosion behaviour of hot pressed CoCrMo biomedical alloy as compared with the cast CoCrMo and Ti6Al4V alloys10.1016/j.matdes.2013.05.032 ↗
13. Evaluation of mechanical and wear properties of Ti-xNb-7Fe alloys designed for biomedical applications10.1016/j.matdes.2016.09.029 ↗
14. Mechanical properties, surface morphology and stability of a modified commercially pure high strength titanium alloy for dental implants10.1016/j.dental.2014.10.002 ↗
15. Friction and wear behavior of Ti-6Al-7Nb biomaterial alloy10.4236/jbnb.2013.44047 ↗
16. Corrosion behaviour of porous Ti-39Nb alloy for biomedical applications10.1016/j.corsci.2013.03.007 ↗
17. Nano-SiC reinforced Zn biocomposites prepared via laser melting: microstructure, mechanical properties and biodegradability10.1016/j.jmst.2019.06.010 ↗
18. Ti based biomaterials, the ultimate choice for orthopaedic implants - a review10.1016/j.pmatsci.2008.06.004 ↗
19. Study of passivation of Al and Al-Sn alloys in borate buffer solutions using electrochemical impedance spectroscopy10.1016/S0013-4686(02)00246-3 ↗
20. Gui · 2016 · vol. 109 · 115
21. A novel antibacterial titania coating: metal ion toxicity and in vitro surface colonization10.1007/s10856-005-4422-3 ↗
22. Wear characteristics of metallic biomaterials: a review10.3390/ma8052749 ↗
23. Wear properties of Ti and Ti-6Al-7Nb castings for dental prostheses10.1016/S0142-9612(02)00533-1 ↗
24. Comparative study on Ti-Nb binary alloys fabricated through spark plasma sintering and conventional P/M routes for biomedical application10.1016/j.msec.2018.10.006 ↗
25. Effects of phase stability and processing on the mechanical properties of Ti-Nb based β Ti alloys10.1016/j.jmbbm.2013.07.007 ↗
26. Infection in orthopedic implant surgery, its risk factors and outcome
27. Electrochemical impedance spectroscopy characterization of passive film formed on implant Ti-6AI-7Nb alloy in Hank's solution10.1023/B:JMSM.0000010097.86245.74 ↗
28. Effect of fluoride-ion implantation on the biocompatibility of titanium for dental applications10.1016/j.apsusc.2008.03.075 ↗
29. Effect of Cu content on the antibacterial activity of titanium-copper sintered alloys
30. Preliminary study on the corrosion resistance, antibacterial activity and cytotoxicity of selective-laser-melted Ti6Al4V-xCu alloys10.1016/j.msec.2016.11.126 ↗
31. The effect of Cu content on corrosion, wear and tribocorrosion resistance of Ti-Mo-Cu alloy for load-bearing bone implants10.1016/j.corsci.2020.109007 ↗
32. Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium10.1016/S0142-9612(00)00275-1 ↗
33. Powder metallurgy : a promising route for bone implants fabrication
34. Fabrication of Ti + Mg composites by three-dimensional printing of porous Ti and subsequent pressureless infiltration of biodegradable Mg10.1016/j.msec.2019.110478 ↗
35. Mechanical properties of biomedical titanium alloys10.1016/S0921-5093(97)00806-X ↗
36. Wear resistance of experimental Ti-Cu alloys10.1016/S0142-9612(03)00157-1 ↗
37. Cytocompatibility of various metal and development of new titanium alloys for medical implants10.1016/S0921-5093(97)00809-5 ↗
38. The roles of macrosegregation and of dendritic array spacings on the electrochemical behavior of an Al-4.5 wt.% Cu alloy10.1016/j.electacta.2006.10.004 ↗
39. Electrochemical behavior of centrifuged cast and heat treated Ti-Cu alloys for medical applications10.1016/j.electacta.2009.09.016 ↗
40. Microstructure, mechanical strength, chemical resistance, and antibacterial behavior of Ti-5Cu-x%Nb biomedical alloy10.1088/1748-605X/ac7763 ↗
41. Antibacterial properties of Ti-6Al-4V-xCu alloys _ elsevier enhanced Reader.pdf10.1016/j.jmst.2013.12.014 ↗
42. Current advances in enhancement of wear and corrosion resistance of titanium alloys – a review10.1080/10667857.2016.1212780 ↗
43. Tribocorrosion and corrosion behavior of quaternary Ti-24Nb-xZr-ySn alloys in SBF10.1016/j.matlet.2020.128903 ↗
44. Roles of copper and O2 in the radiation-induced inactivation of T7 bacteriophage10.2307/3576330 ↗
45. Mortality and cost associated with cardiovascular implantable electronic device infections10.1001/archinternmed.2011.441 ↗
46. Interactions of heavy metals with minerals10.1016/0048-9697(80)90122-9 ↗
47. Structure and properties of Ti-Ag alloys produced by powder metallurgy10.1016/j.jallcom.2017.03.155 ↗
48. Production of new titanium alloy for orthopedic implants10.1016/j.msec.2004.08.011 ↗
49. Studies of Ti alloys for dental castings10.1016/0109-5641(89)90093-6 ↗
50. Microstructure, mechanical properties and antibacterial properties of the microwave sintered porous Ti–3Cu alloys10.1016/j.jallcom.2019.152142 ↗
51. The molecular mechanisms of copper and silver ion disinfection of bacteria and viruses10.1080/10643388909388351 ↗
52. Corrosion and tribocorrosion behaviour of β-type Ti-Nb and Ti-Mo surfaces designed by diffusion treatments for biomedical applications10.1016/j.corsci.2018.06.024 ↗
53. Dry sliding wear behaviour of β-type Ti-Nb and Ti-Mo surfaces designed by diffusion treatments for biomedical applications10.1016/j.jmbbm.2018.12.029 ↗
54. Wear performance of Al-SiC-B4C hybrid composites under dry sliding conditions10.1016/j.matdes.2012.11.059 ↗
55. The effect of nitrogen diffusion hardening on the surface chemistry and scratch resistance of Ti-6Al-4V alloy10.1016/S0142-9612(00)00049-1 ↗
56. Optimization of mechanical property, antibacterial property and corrosion resistance of Ti-Cu alloy for dental implant10.1016/j.jmst.2019.03.044 ↗
57. Fabrication of Ti-Nb-Ag alloy via powder metallurgy for biomedical applications10.1016/j.matdes.2013.11.066 ↗
58. Microstructure and dry wear properties of Ti-Nb alloys for dental prostheses
59. Microstructure, mechanical properties and dry wear resistance of β-type Ti-15Mo-xNb alloys for biomedical applications10.1016/S1003-6326(13)62518-2 ↗
60. Effect of Ag on the corrosion behavior of Ti-Ag alloys in artificial saliva solutions10.1016/j.dental.2008.10.016 ↗
61. Effect of Sn addition on the microstructure and superelasticity in Ti-Nb-Mo-Sn Alloys10.1016/j.jmbbm.2012.04.017 ↗
62. A new antibacterial titanium-copper sintered alloy: preparation and antibacterial property
63. Effect of Nb addition on microstructure, mechanical properties and castability of β-type Ti-Mo alloys10.1016/S1003-6326(15)63834-1 ↗
64. Effect of the existing form of Cu element on the mechanical properties, bio-corrosion and antibacterial properties of Ti-Cu alloys for biomedical application10.1016/j.msec.2016.08.033 ↗
65. Fibroblast responses and antibacterial activity of Cu and Zn co-doped TiO 2 for percutaneous implants10.1016/j.apsusc.2017.10.169 ↗